278 resultados para Evaluation of the services
Resumo:
Objective: The aim of this study was to evaluate the thermoplasticity of three commercial brands of gutta-percha (Tanari, Dentsply 0.06, and Roeko), and of the TC system. Materials and Methods: Standardized specimens were fabricated from the materials to be evaluated. Specimens were placed in water at 70°C for 60 seconds. Following that, they were positioned between two glass slabs and each set was compressed by a 5kg weight. Images of the specimens before and after compression were digitized and analyzed by the Image Tool software. The flow capacity of each material was confirmed by the difference between the initial and final areas of each sample. Results: The resulting data were analyzed by ANOVA. The TC system presented the greatest thermoplasticity values (p<0.05). Among the gutta-percha cones, the Roeko brand showed higher thermoplasticity than the others (p<0.05). Conclusion: The gutta-percha from TC system present good thermoplasticity capacity.
Resumo:
The goal of this study was to evaluate the thermoplasticity of conventional and thermoplastic gutta-percha and Resilon®, a polyester polymer-based material. Specimens with standardised dimensions were made from the following materials: conventional and thermoplastic gutta-percha (Dentsply), conventional and thermoplastic gutta-percha (Endopoints) and Resilon®. After 24 h, the specimens were placed in water at 70°C for 60 s, and thereafter positioned between two glass slabs. Each set was compressed by a 5-kg weight. Digital images of the specimens before and after compression were obtained and analysed. The thermoplasticity of each material was confirmed by the difference between final and initial areas of each sample. The data were analysed statistically by ANOVA and Tukey's test at a 5% significance level. Resilon® had the highest thermoplasticity means (P < 0.05). Among the gutta-percha cones, Endopoints TP (thermoplastic) presented the highest thermoplasticity means and differed significantly from the other commercial brands (P < 0.05). Resilon® had good thermoplasticity, endorsing its use as a thermoplastic root canal filling material. © 2007 The Authors. Journal compilation © 2007 Australian Society of Endodontology.
Resumo:
The biology and productivity of Myschocytarus drewseni were studied in semi urban conditions at Rio Claro, S P - Brazil. We observed 51 nest foundations, of which 24 (47%) were destroyed or predated, 13 (25.5 %) were abandoned and 14 (27.5%) completed the cycle. The life-span of colonies ranged from 44-427 days with a mean of 216.7 ± 140.6 days, producing 8-390 cells with a mean of 125.7 ± 137.9 cells, and 2-303 adults with a mean of 89.4 ± 110.36 adults. We observed a maximum of 3 utilizations/cell. This showed that the species presents asynchronous foundation and abandoningoccurs throughout the year. Also, the chance of a colony utilizing the same cells two or three times for adult production is highly dependent on the colony size/age, and the relation between them is positive, meaning that there is a greater chance of cell re-utilization in larger/older colonies.
Resumo:
The purpose of this study was to evaluate in vivo the biocompatibility of Endométhasone, Pulp Canal Sealer EWT and AHPlus root canal sealers after implantation in rat connective tissue. Twenty-four Wistar-Furth rats were used. Polyethylene tubes were filled with the sealers and implanted into specific dorsal subdermal tissue sites of the rats. Implants were removed after 3, 7 and 30 days, fixed and processed for glycol methacrylate-embedding technique to be examined microscopically. On the 3rd day, there was a mild inflammatory reaction to Pulp Canal Sealer EWT implants, but a severe response to the other sealers with presence of acute inflammatory cells. On the 7th day, tissue organization was more evident with attenuation of the inflammatory reaction, especially for the AH-Plus implants. On the 30th day, connective tissue with few inflammatory cells was observed in contact with all sealer implants. In this time interval, the tissue in contact with Pulp Canal Sealer EWT implants was more organized, while the tissue close to Endométhasone and AH-Plus implants showed a mild persistent inflammatory reaction and had similar results to each other. In conclusion, the sealers had a similar pattern of irritation, which was more severe in the beginning and milder with time, in such a way that all sealers showed a persistent mild reaction. Pulp Canal Sealer EWT yielded better tissue organization than Endométhasone and AH-Plus, which, in turn, showed similar results to each other.
Resumo:
Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.
Resumo:
The aim of this study was to present a possible carrier for MTA, monoolein gel, with the objective to maintain this material in the place that was inserted and verify if this procedure is able to optimize its action. The data were evaluated by histomorphometric method and submitted to statistical analysis. The histological responses observed in this study indicate that the MTA is a reliable material and should be considered effective in bone periapical defects and the monoolein gel was capable to maintain the MTA in situ.
Resumo:
Toothpastes usually contain detergents, humectants, water colorant, fluoride and thickeners (e.g. silica). Tooth wear has a multi-factorial etilology and the use of abrasive dentifrices is related to abrasion of dental tissues during toothbrushing. This study evaluated in vitro the abrasiveness of a commercial silica gel low-abrasive dentrifice compared to an experimental dentifrice containing vegetable (almond) oil. Distilled water served as a control group. Acrylic specimens (8 per group) were submitted to simulated toothbrushing with slurries of the commercial dentifrice experimental dentifrice, almond oil and water in an automatic brushing machine programmed to 30,000 brush strokes for each specimen which is equivalent to 2 years of manual toothbrushing. Thereafter, surface roughness (Ra) of the specimens was analyzed with a Surfcorder SE 1700 profilometer. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) in the surface roughness after brushing with water almond oil experimental dentifrice. The commercial dentifrice produced rougher surfaces compared to the control and abrasive free products (p<0.05). Further studies are necessary in confirm the potential benefits of using vegetable oil in toothpaste as an alternative in abrasives in an attempt to minimize the tooth wear caused by toothbrushing.
Resumo:
The patient's diet has been considered an important etiological factor of dentin hypersensitivity. The frequent ingestion of acidic substances can promote the loss of dental structure or remove the smear layer. The purpose of this study was to evaluate the degree of smear layer removal and dentinal tubules exposure by different natural orange juices. Extracted human teeth were submitted to manual scaling in order to develop the smear layer. Seventy dentin samples were obtained and distributed into the following groups: Control, lime orange, lime, valência orange, navel orange, mandarin, and tangerine. Each group included 2 methods of application: Topical and topical + friction. After preparation for SEM analysis, photomicrographs were assessed by a blind calibrated examiner using an index system. The Kruskal-Wallis test indicated a significant influence of the orange juices on smear layer removal. Significant difference was observed between navel orange, valência orange, mandarin and the control group (p < 0.05). These orange juices resulted in greater removal of the smear layer and greater opening of dentinal tubules. The comparison between the application methods for each group using the Mann-Whitney test showed that friction increased smear layer removal significantly only for lime orange and lime. The data suggest that certain natural orange juices are more effective in terms of smear layer removal and dentinal tubules exposure than others.
Resumo:
Introduction: Urinary tract infection (UTI) is a very common condition in clinical practice, affecting an estimated 50% of all adult women during a lifetime. The most common causative agent is E. coli; UTI may also be caused by S. saprophyticus, Enterobacteria (Klebsiella sp and Serratia sp.), Enterococcus sp., and P aeruginosa. Recurrent UTIs occur at least twice per semester or three times a year. Prophylactic measures to prevent recurrent UTIs include changes in contraception methods, cranberry products, increased fluid intake, urination after intercourse, vaginal estrogen therapy for post-menopausal women, antibiotics, and urinary tract antiseptic agents. Objectives: To evaluate the use of a combination of methenamine and methyl-thioninium chloride in the prophylaxis of recurrent uncomplicated lower UTIs, with respect to: • Signs and symptoms of UTI • Etiologic agent(s) • Recurrence rates • Need for antibiotic therapy in case of recurrence • Incidence of adverse events associated with the treatment, including any reported alterations of laboratory tests Materials & methods: A descriptive, analytic, restrospective study was performed at Hospital Universitário Constantino Otaviano - UNIFESO. Medical charts from patients presenting recurrent uncomplicated lower UTI attended from 2001-present were analyzed, including the following information: Demographic data (age, gender, weight, ethnicity, living conditions): medical history/signs and symptoms of UTI; identification of treatment and dosing regimens; treatment duration; recurrence rates and need for antibiotic therapy in case of recurrence; other medications prescribed; and records of adverse events. Results: E. coli was identified as etiologic agent in 80% of the patients. Following antibiotic therapy, all patients received prophylactic treatment with the combination of methenamine and methylthioninium chloride. Treatment duration ranged from three to six months. Adverse events were observed in 13/60 patients (21.7%). At the end of the respective treatment periods, a statistically significant (p<0.0001) number of patients showed no UTI recurrence. Conclusion: Based on the results from the collected data, we conclude that an orally administered combination of methenamine and methylthioninium chloride is safe and effective in the prophylactic treatment of recurrent uncomplicated lower urinary tract infection. © Copyright Morelra Jr. Editora.
Resumo:
This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.
Resumo:
Due to their high hardness and wear resistance, Si3N4 based ceramics are one of the most suitable cutting tool materials for machining cast iron, nickel alloys and hardened steels. However, their high degree of brittleness usually leads to inconsistent results and sudden catastrophic failures. This necessitates a process optimization when machining superalloys with Si3N4 based ceramic cutting tools. The tools are expected to withstand the heat and pressure developed when machining at higher cutting conditions because of their high hardness and melting point. This paper evaluates the performance of α-SiAlON tool in turning Ti-6Al-4V alloy at high cutting conditions, up to 250 m min-1, without coolant. Tool wear, failure modes and temperature were monitored to access the performance of the cutting tool. Test results showed that the performance of α-SiAl0N tool, in terms of tool life, at the cutting conditions investigated is relatively poor due probably to rapid notching and excessive chipping of the cutting edge. These facts are associated with adhesion and diffusion wear rate that tends to weaken the bond strength of the cutting tool.
Resumo:
The purpose of this study was to assess the influence of cleaning pits and fissures with an aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods: The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnifi cation was used as the gold standard. Results: Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and a specifi city of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specifi city of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.
Resumo:
The present study aimed at analyzing and comparing longitudinally the EMG (electromyographic activity) of the superior orbicularis oris muscle according to the breathing mode. The sample, 38 adolescents with Angle Class II Division 1 malocclusion with predominantly nose (PNB) or mouth (PMB) breathing, was evaluated at two different periods, with a two-year interval between them. For that purpose, a 16-channel electromyography machine was employed, which was properly calibrated in a PC equipped with an analogue-digital converter, with utilization of surface, passive and bipolar electrodes. The RMS data (root mean square) were collected at rest and in 12 movements and normalized according to time and amplitude, by the peak value of EMG, in order to allow comparisons between subjects and between periods. Comparison of the muscle function of PNB and PMB subjects at period 1 (P1), period 2 (P2) and the variation between periods (Δ) did not reveal statistically significant differences between groups (p < 0.05). However, longitudinal evaluation of the muscle function in PNB and PMB subjects demonstrated different evolutions in the percentage of required EMG for accomplishment of the movements investigated. It was possible to conclude that there are differences in the percentage of electric activity of the upper lip with the growth of the subjects according to the breathing mode.
Resumo:
AIM: This in vitro study evaluated the abrasiveness of acidic fluoride (F) dentifrices with different F concentrations on bovine enamel. METHODS: Enamel blocks (4.0 x 4.0 mm2, n=120) were selected according to their surface microhardness and divided into 12 groups. Slurries of dentifrices were used containing 0 (placebo), 275, 412, 550 and 1,100 ppm F (pH 4.5 or 7.0), as well as testing two commercial dentifrices (Crest, positive control, 1,100 ppm F and Colgate Baby, 500 ppm F). Enamel blocks were partially protected with an adhesive tape (control area) and then brushed by an automated toothbrushing machine (16,000 strokes). During this process, 0.4 ml of the slurries were injected every 2 mins on the enamel blocks. After toothbrushing, enamel wear was determined by profilometry. STATISTICS: Results were analyzed by ANOVA and Tukey's test (p<0.05). RESULTS: The mean values for pH in the suspensions during treatment were 6.93, 4.32, 7.56 and 8.19 for neutral experimental dentifrices, acidic experimental dentifrices, Crest and Colgate baby, respectively. The abrasiveness of the acidic dentifrices was similar (p<0.05) to the neutral ones, whereas commercial dentifrices yielded lower abrasion (p<0.05). CONCLUSION: It was concluded that a reduction of the pH of dentifrices does not increase their abrasiveness.
Resumo:
This is the first study performed with an interocclusal splint with a vibrating device on patients with sleep bruxism. The purpose of the present study was to evaluate the effectiveness of the splint with vibrating device on patients who suffer from sleep bruxism through computerized electromyography (EMG) of the anterior temporal muscles. Eight male and female patients, ranging in age from 18 to 28 years, with evident signs and symptoms of bruxism were selected. The splint were made for the upper arch. The patients was treated with the interocclusal splint with a vibrating device, and submitted to EMG evaluations of the anterior temporal muscles on both sides. The evaluations were performed at the beginning of treatment and after 21 days of splint use. Electromyography was performed in an isometric contractions measuring of the temporal muscles. The following results obtained revealed that: when closing the mandible (isometric contraction), the anterior temporal muscles had an expressive reduction in electromyographic activity (p. < 0.10), so this splints were considered effective for patients who suffer from sleep bruxism. © 2009 Springer-Verlag.