269 resultados para Alta do doente


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method to determine Ca, K and Mg in a single aliquot of medicinal plants by HR-CS FAAS is proposed. The secondary lines for Ca (239.856 nm) and K (404.414 nm), and the alternate line measured at wing of the secondary line for Mg at (202.588 nm) allowed calibration within the 20 - 500 mg.L-1 Ca and K, and 1.0 - 80 mg.L-1 Mg. Twenty samples and three plant certified materials were analyzed. Results were in agreement at a 95% confidence level with reference values. Limits of detection were 2.4 mg.L-1 Ca, 1.9 mg.L-1 K and 0.3 mg.L-1 Mg. The RSD (n=12) were ≤ 5.1% and recoveries were between 83 and 108% for all analytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).