250 resultados para Adesivo epossidico
Resumo:
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
Resumo:
The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this study was to evaluate the apical sealing ability and the marginal adaptation of five dental materials used in retrofillings or applied to the bevelled root surface. One hundred and forty extracted single rooted human teeth were used, divided into seven groups of twenty each. ln the first, second, third and fourth groups, the teeth were apicoectomized, submitted to cavity preparations and retrofilled with one of the following materiais: zinc free silver amalgam, a dentin bonding system plus composite resin, a glass ionomer cement ora compomer. In the fifth, sixth and seventh groups, the teeth were apicoectomized and capped on the bevelled root surface with one of the following materiais: a dentin bonding system plus composite resin, a glass ionomer cement or a compomer. Two specimens of each experimental group were evaluated for the marginal adaptation using scanning electron microscopy. The remaining 126 specimens were immersed in 2% methylene blue dye, stored for one week at 37ºC and the infiltration was evaluated with a stereomicroscope. The results showed that the glass ionomer cement presented the lowest values of marginal infiltration when used as retrofilling material, with a significant statistical difference when compared with the others tested materials. When used as apical capping, the glass ionomer cement and the compomer were equivalent and significantly better than the dentin bonding system plus composite resin. Using scanning electron microscopy, all the materials showed some slight adjustment problem. ln the retrofilling, the smallest marginal gaps were observed with the compomer and the dentin bonding system plus composite resin, while the largest were observed with the glass ionomer cement and zinc free silver amalgam. ln the apical capping, the smallest marginal gaps were observed with the compomer and the dentin bonding system plus composite resin and ...
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Objective: Evaluate the impact of the use of strip adhesive over the quality of life of institutionalized patients and wearers of complete dentures. Material and method: Twenty-nine institutionalized patients wearers of complete denture were selected to this study and after a clinical exam, a questionnaire (adjusted and based upon the index of Oral Health Impact Profile and Oral Health-Related Quality of Life, OHIP and OHQOL) was applied to evaluate issues related to epidemiological conditions (gender and age), quality of life (pain, discomfort, functional limitations, phonetic, social, psychological and esthetic), taste and notion of implant treatment. Following this part, the patients received instruction to use the strips adhesives (Corega Fita Adesiva, Glaxo-Smith-Kline, Rio de Janeiro, Brazil), considering three in maxillary prosthesis and two in the lower prosthesis during a period of 30 days. After this period, all the patients were recall and the questionnaire was reapplied; add some adhesive performance questions, to compare the results before and after the adhesive use in terms of percentage. Result: After the adhesive strips use there were improvement of the functional, social and physcological limitation aspects, but without percentual increasement of phonetic and esthetics aspects. The results showed 65.5% of the answers stating adhesive maintenance between 6-12 hours, easy removal (68.9%), and without change the taste (89.6%). The notion for implant treatment was decreased changing from 75.8 to 37.9% after the adhesive use. Conclusion: The results enhanced a positive impact over quality of life of the respondents after the strip adhesive use, showing decrease of pain and discomfort, mainly of inferior dental prosthesis.
Resumo:
The bone repair process is controlled by complex molecular mechanisms that involve systemic and local factors. Fibrin glue is derived from human plasma and mimics the final pathway of coagulation network. Tranexamic acid inhibits fibrinolysis and prevents or decreases the formation of degradation products of fibrin and fibrinogen. The purpose of this study was to evaluate histologically in rats the effect of tranexamic acid associated with the fibrin glue on bone healing. The experiment used 60 (n = 5) male rats in: GI: Control, GII: fibrin glue, GIII tranexamic acid and GIV /fibrin glue/tranexamic acid. Bone defect (2.5mm diameter) was created in right tibia. The animals were euthanized at 7,14 and 30 days postoperatively, and the pieces were processed with hematoxylin and eosin. The results showed at 7 days post-operative surgical cavity filled with dense connective tissue rich in fibroblasts, permeated by delicate neoformed bone trabeculae in percentage of 70-80% for GI, GII and GIII and GIV to 94.8%. At 14 days post-operative newly formed bone was found between 75-85% for GI, GII and GIII and percentage above 95% for GIV. At 30 days postoperative GI and GIV showed 95-100% of mature bone tissue; GII and GIII in percentage close to 80-90%. Based on the results and methodology is concluded that fibrin / tranexamic acid glue association has positive action on bone repair.
Resumo:
The purpose of this study was to evaluate the effects of two conditioning methods used to enhance the shear strength of orthodontic brackets bonded to porcelain surfaces. A total of 18 feldspathic specimens were used. The specimens were divided randomly into two groups (n = 9): group free silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive); group silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by silane (Silano Ângelus) for 1 minute, adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive). All specimens were stored in solution of artificial saliva at ambient temperature for 24 hours. The debonding was done with shear strength through a universal testing machine (DL 500-Emic) calibrated with a fixed speed of 1mm/minute. Statical analysis was performed using the Student t test. The results indicated that in the free silane group the mean bond strength was 9,97 MPA, significantly lower than the silane group, that was 12,38 MPa (p < 0,05). The both groups were effective for bonding, although the silane group had the highest bond strength values.
Resumo:
Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: This confocal microscopy study evaluated the cement/dentin and cement/post interfaces along theroot canalwallswhenfiberglasspostswerebonded to dentin using different types of cements. Material & Methods: Thirty endodontically treated premolars were divided into 3 groups according to the adhesive materials used in the bonding procedure: Prime & Bond 2.1/Self Cure + Enforce, RelyX Unicem and RelyX Luting. Rhodamine B dye was incorporated in the luting materials for the cementation of the fiber glass posts (Exacto, Angelus) to dentin. Three transversal slices (apical, middle and coronal) were examined under confocal laser scanning microscopy. Statistical analysis was performed using the Kappa, Kruskal-Wallis and Dunnet tests, in a significance level of 5%. Results: The Prime & Bond 2.1/Self Cure + Enforce presented a uniform formation of tags in the dentin but gaps in the cement/dentin interface. The RelyX Unicem and RelyX Luting presented an adhesive interface with a fewer amount of gaps, but showed shorter tag formation than the Enforce system. All cements presented the same pattern of bubbles inside the cements. The RelyX Luting presented a greater amount of cracks inside the cement in comparison with the other cements in the coronal third, while no difference was observed between RelyX Unicem and Enforce. The RelyX Luting showed the lowest quantity of cement penetration into the post. Conclusion: In general, the quality of bonding interfaces of fiber posts luted to root canals was affected by both location and type of cement.
Resumo:
Objetivo: a proposta desse estudo foi avaliar, por meio de microscopia eletrônica de varredura (MEV), a interface adesiva após a descolagem de acessórios ortodônticos, fixados em dentes bovinos com emprego de adesivo hidrofílico e hidrofóbico, em condições distintas de umidade do substrato dentário. Métodos: foram utilizados 20 incisivos inferiores, divididos em quatro grupos (n = 5): Grupo I , empregou-se o sistema de colagem contendo o primer hidrofílico Transbond MIP e a pasta adesiva Transbond XT, aplicados em substrato úmido; Grupo II, empregou-se o sistema de colagem primer hidrofóbico Transbond XT e pasta adesiva em substrato úmido; Grupos III e IV, os braquetes foram colados com os mesmos sistemas de união dos Grupos I e II, porém com esmalte dentário seco. Removidos os acessórios, avaliou-se em MEV, em diferentes magnificações, a interface adesiva e a interação dos sistemas adesivos com o esmalte dentário. As imagens foram avaliadas qualitativamente, observando-se o embricamento mecânico para o adesivo hidrófilo em quaisquer condições de substrato. Resultados: a falta de umidade no esmalte condicionado permitiu uma melhor interação entre os materiais de ligação e a estrutura adamantina. O adesivo hidrofóbico apresentou o pior resultado de interação micromecânica quando aplicado a uma estrutura dentária úmida; já o sistema hidrofílico mostrou-se versátil, obtendo resultados aceitáveis em condições de umidade e excelente interação na ausência de contaminação. Conclusão: os autores afirmam que a melhor condição do esmalte dentário para a aplicação de primers é com a ausência de umidade.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT