228 resultados para sagittal suture
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Obesity has been considered the key in metabolic syndrome (MetS) development, and fat accumulation may be responsible for the occurrence of metabolic abnormalities in hemodialysis patients. The use of gold-standard methods to evaluate obesity is limited, and anthropometric measures may be the simplest methods. However, no study has investigated the association between anthropometric indexes and MetS in these patients. Therefore, the aim was to determine which anthropometric indexes had the best association and prediction for MetS in patients undergoing hemodialysis. Cross-sectional study that included patients older than 18 years, undergoing hemodialysis for at least 3 months. Patients with liver disease and cancer or those receiving corticosteroids or antiretroviral therapy were excluded. Diagnostic criteria from Harmonizing Metabolic Syndrome were used for the diagnosis of MetS. Anthropometric indexes evaluated were body mass index (BMI); percent standard of triceps skinfold thickness and of middle arm muscle circumference; waist circumference (WC); sagittal abdominal diameter; neck circumference; waist-to-hip, waist-to-thigh, and waist-to-height ratios; sagittal index; conicity index; and body fat percentage. Ninety-eight patients were included, 54.1% male, and mean age was 57.8 ± 12.9 years. The prevalence of MetS was 74.5%. Individuals with MetS had increased accumulation of abdominal fat and general obesity. Waist-to-height ratio was the variable independently associated with MetS diagnosis (odds ratio, 1.21; 95% confidence interval, 1.09-1.34; P < .01) and that better predicts MetS, followed by WC and BMI (area under the curve of 0.840, 0.836, and 0.798, respectively, P < .01). Waist-to-height ratio was the best anthropometric predictor of MetS in maintenance hemodialysis patients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
The Temporomandibular Joint is a noble structure of the complex mandibular, a lot of research was conducted on the to signs and symptoms of the alterations that attack those structures. ln spite of the high incidence of the DTM in children, there's little knowledge about it, wich makes difficult the treatment Desorders Craniomandibulares (DCM) or Desorders Temporomandibulars (DTM). The Temporomandibular Joint is composed basically by three elements: bones, muscles and disk, in relation to bony part, we have the fossae mandibular that is part of the temporary bone and wich houses the condyle mandibular, accomplishing the articulation among the cranium and the jaw (it leaves piece of furniture of the articulation). Our intention in that work was of verifying a possible asymmetry of the fossae mandibular on the left side and of the right side in relation to two straight line: a straight line that coincided with the plane medium sagittal and another perpendicular straight line to the plan medium sagittal. Analyzing, the fossae mandibular in 91 dry craniums of children, with age varying between four months of life intrauterina and five years, in x-rays in that the incidence was cranium-flow, we could end that: in spite of we find statistical significance in relation to that asymmetry, clinic cannot affirm that interferences on occlusion exists for that asymmetry
Resumo:
Many incisions have been described for approaches to zygomatic fractures. Precise repositioning of zygomatic complex fractures is difficult. The traditional approach is through an eyebrow incision, but it can produce a scar that causes aesthetic and psychological problems for the patient. We describe the supratarsal fold approach to expose the frontozygomatic suture and to reduce small displacements of frontal sinus anterior wall; it gives good access and excellent aesthetic results.
Resumo:
Facial injuries vary in their clinical characteristics and complexity, deserves an appropriate approach for each case, considering that the failures may result in aesthetic and functional changes that can be harmful both functionally and psychologically. Aspects such as exposure time of the injury, anesthesia, suture materials and tetanus prophylaxis are important factors. The objective is to present a case of extensive facial injuries in an automobile accident patient.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.
Resumo:
Objective: To compare two forms of scheduling clinical dental care for the oral health teams (OHT) included in the strategy of family health, regarding productive aspects of assistance. Methods: Two OHT worked concurrently, using two methods of clinical care: the parameter recommended by the Ministry of Health Ordinance No. 1101, 2002, which establishes 03 dental visits per hour (c/h) per team, and a Testing model, with 02 c/h, being each method applied for a period of 615 hours. The quantitative data was collected in OHTs’ daily production spreadsheets, covering the following items: the number of dental visits (initial, for maintenance and for emergency procedures), procedures performed, consumption of material and sterilization cycles. Data was compared and statistically analyzed through the BioStat 5.0 by applying the paired t-test (p <0.05). Results: Under the Ministerial method and the Testing model, were performed, respectively, 288 and 365 first dental visits, 921 and 686 return dental visits, 167 and 172 emergency dental attendances, with 469 and 110 fouls, 212 and 327 treatments were finished and 2501 and 3046 dental procedures were realized. Among eleven analyzed consumables, five were consumed in smaller quantities in the Testing model: gloves (9%), anesthesia (38%), anesthetic needle (34%), suture material (24%) and aspirators (11%), while the six remaining items presented similar consumption rates between the two models. Conclusions: The testing model revealed to be more productive and economical.
Resumo:
Calvaria grafts provide good bone quantity for the reconstruction of the atrophic maxilla, and have lower morbidity and resorption rates when compared to iliac crest. The aim of this paper is to present the technique for obtaining a graft of the skull. Initially, the depth of the osteotomy is determined by a manually conducted bur, which establishes the limits of the structures of the skull (outer table, diploe and inner table), making the removal of bone blocks easier and safer. Thus, osteotomies of the blocks are made with greater security, avoiding the complications inherent to surgical technique. The case that will be presented it is from a male patient of 65 years who refused to submit to the iliac crest graft, opting for the calvaria, despite being bald, that is a contraindication for this treatment modality. A delicate suture associated with placement of titanium mesh to maintain the conformation of the patient's skull in the region of the bone defect, created after removal of the graft, provided a good cosmetic result at the donor site. The use of titanium mesh for re-anatomization of bone defects created in the grafts is well indicated for bald patients.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Psicologia - FCLAS