571 resultados para removable denture
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Statement of problem. Removable partial dentures are affected by fatigue because of the cyclic mechanism of the masticatory system ansi frequent insertion and removal. Titanium and its alloys have been used in the manufacture of denture frameworks; however, preventive agents with fluorides are thought to attack titanium alloy surfaces.Purpose. This study evaluated, compared, analyzed the corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different storage environments.Material and methods. For each metal, 33 dumbbell rods, 2.3 mm in diameter at the central segment, were cast in the Rematitan system. Corrosion-fatigue strength test was carried out through a universal testing machine with a load 30% lon er than the 0.2% offset yield strength and a combined influence of different: environments: in air at room temperature, with synthetic saliva, and with fluoride synthetic saliva. After failure, the number of cycles were recorded, and fracture surfaces were examined with on SEM.Results. ANOVA and Tukey's multiple comparison rest indicated that Ti-6Al-4V alloy achieved 21,269 cycles (SD = 8,355) against 19,157 cycles (SD = 3,624) for the commercially purr Ti. There were no significant differences between either metal in the corrosion-fatigue life for dry specimens, but when the solutions were present, the fatigue life was significantly reduced, probably because of the product-ion of corrosion pits caused by superficial reactions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.
Resumo:
The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The primary teeth are essential for bone development and establishment of the arches on occlusion. Thus, the congenitally absence of teeth may trigger a shift in the balance of the occlusion, promoting disharmony in the structures of the maxilla-mandibular system. However, some interventions are possible to be performed in these cases even in pediatric patients, to redirect growth, preventing growth deviations and reestablishing the aesthetic. The aim of this paper is to report the treatment of a 4-year-old child presenting congenitally absence of mandibular central and lateral incisors and maxilla lateral incisors, which consequently compromises aesthetics, occlusal function, and the development and the functional growth of the bones. The oral rehabilitation was performed with an adhesive partial denture, which was able to restore the aesthetic and the occlusal function, therefore being a viable alternative in the treatment of this patient of little age.
Resumo:
Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.
Resumo:
The information about the knowledge and usage of denture adhesives is still limited, particularly in Brazilian populations. Objective: The purpose of this study was to investigate the aspects related to the use or nonuse of denture adhesives by complete denture wearers. Material and method: Questionnaires were applied to 100 bimaxillary complete denture wearers concerning their usage of denture adhesives. The survey was carried out according to three categories: those who had never tried adhesive, those who had tried adhesive at least once but no longer used it, and those who currently used it. Result: Of the 100 participants, 80% had never tried adhesives, 16% had tried at least once but no longer used it and 4% had used on a regular basis. Conclusion: Within the limitations of this study, the results of this subjective assessment suggest that within the participants that had never tried adhesives, 77.5% inform that the adhesive is not needed, and all participants who regularly use it inform its efficiency.
Resumo:
The objective of this study was to present a systematized review of different methods used to evaluate the masticatory efficiency in conventional complete denture wearers. A survey was conducted in the databases PubMed, Scopus, and Cochrane, seeking scientific articles according to the previously selected terms: "Masticatory performance", "Masticatory efficiency" and "Chewing ability complete denture". Moreover, complementary studies have been carried out with library manual search/databases, which included studies related to different ways to assess masticatory efficiency, specifically as it related to conventional complete denture wearers. Forty three papers were selected to be used in the present review. Despite the wide variety of methodologies in the literature, the sieves method is currently considered the gold standard method to evaluation of conventional complete denture wearers masticatory efficiency, since it is the simplest, does not depend on specific devices (beyond the set of sieves), allows for a rational assessment, and it has been widely reproduced in various types of oral rehabilitation. More, the almond, as natural test food, and the optocal (made from the molding material Optosil), as artificial test food, are the most constantly employed test foods to evaluate masticatory efficiency.
Resumo:
Introduction: the oral rehabilitation in edentulous patients using removable complete dentures is a classic treatment, easily accessible, and presenting satisfactory results. However, to succeed in this type of treatment, stability is an extremely important factor. The neutral zone technique for the production of complete dentures determines the oral cavity space for the positioning of teeth and denture base that provide a neutralization of the forces delivered by lips, cheeks, and tongue, providing better stability and retention of prostheses, which is indicated in cases with history of difficulties in adapting the conventional mandibular denture. Objective and case report: this paper aimed to describe a clinical case report of the oral rehabilitation of a patient with paraprosthetic muscles hypertonicity through removable complete dentures produced by the neutral zone technique, using condensation silicone. Final considerations: the use of condensation silicone for the development of the neutral zone technique showed to be a good alternative for the development of this clinical case, providing satisfactory stability and retention of the complete mandibular denture.
Resumo:
Introduction: Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. Objective: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. Literature review and conclusion: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.
Resumo:
Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments.
Resumo:
Epidemiological researches are important to understand the distribution and etiology of oral diseases. The actual researches that show the relationship between patient ages, denture status and denture stomatitis are scarce. So, the aim of this study was to identify of Candida spp. in patients with Denture Stomatitis (DS) and to correlate with gender, age, time of denture use and Newton’s classification. 204 complete denture patients (46 males and 158 females) were selected. DS was classified according to Newton’s classification and it was related to gender, age and time of denture use. Samples from the palatal mucosa and the surface of the upper denture of patients with DS were evaluated using PCR test for identification of Candida species. T-test, chisquare and Fisher’s exact tests were used for statistical analysis. DS was evidenced in 54.4% of the sample. According to gender 41.3% of the males and 58.3% females had the disease and the differences were statistically significant (p = 0.032). The type of DS was directly influenced by the time of denture use (p<0.001), but it was not significantly related to the age of the participants (p>0.05). C. albicans, C. tropicalis, C. glabrata, C. krusei and C. dubliniensis were identified by PCR test. DS is more prevalent in women and the prevalence of DS was influenced by the time of denture use (years). C. albicans was identified as the most frequent specie in patients with DS.
Resumo:
Aim: The role of saliva on Candida adhesion to biomaterials has not been clearly defined. The present study investigates whether different periods of preconditioning with saliva would influence the adhesion of Candida albicans to a denture base resin. Methods: Ninety samples of acrylic resin with smooth surfaces were made and then divided into five groups: one control without saliva, and four experimental groups conditioned in saliva for periods of 30 min, 1, 3, or 12 h. Candida adhesion was evaluated by crystal violet staining and 2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-5-([phenylamino] carbonyl)-2H-tetrazolium-hydroxide assay. Results: The one-way analysis of variance revealed that there were no significant differences among the mean number of adherent cells or among the mean absorbance for all groups. No significant correlation was found between the two methods used for assessing Candida albicans adhesion. Conclusion: The different periods of preconditioning with saliva had no significant influence on the adhesion of Candida albicans to the denture base acrylic resin.