218 resultados para human teeth


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental recognition is very important for forensic human identification, mainly regarding the mass disasters, which have frequently happened due to tsunamis, airplanes crashes, etc. Algorithms for automatic, precise, and robust teeth segmentation from radiograph images are crucial for dental recognition. In this work we propose the use of a graph-based algorithm to extract the teeth contours from panoramic dental radiographs that are used as dental features. In order to assess our proposal, we have carried out experiments using a database of 1126 tooth images, obtained from 40 panoramic dental radiograph images from 20 individuals. The results of the graph-based algorithm was qualitatively assessed by a human expert who reported excellent scores. For dental recognition we propose the use of the teeth shapes as biometric features, by the means of BAS (Bean Angle Statistics) and Shape Context descriptors. The BAS descriptors showed, on the same database, a better performance (EER 14%) than the Shape Context (EER 20%). © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is becoming more common for patients to look for cosmetic procedures in dental offices. The search for lost or desired esthetics by patients is increasingly frequent and the professional must be able to meet this demand. To do this, dentists not only need to return the tooth back to its normal functioning state but also promote esthetic excellence. In this context, the association of cosmetic procedures, such as teeth whitening and restorative procedures, such as direct adhesive restorations is very common. The composite resins employed nowadays allow the reproduction of various optical properties of natural teeth. With these composite resins, it is possible to reproduce features such as translucency, opacity and specific features of the dental element, to bring back the esthetic harmony of the smile. This article reports a clinical case demonstrating the placement, in a stratified manner, of composite resins in bleached teeth, as well as the reproduction of optical and natural aspects of the teeth. In order to achieve esthetic and functional success of the restored procedure, it is important to be familiar with the new techniques and new materials in the marketand above all, we must know when and where to use them.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D 1 threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D 2 threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D 3 threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility. © 2012 Springer-Verlag London Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To comparatively and prospectively compare in a randomized clinical trial, dentin hypersensitivity after treatment with three in-office bleaching systems, based on hydrogen peroxide at different concentrations, with and without light source activation. Methods: 88 individuals were included according to inclusion and exclusion criteria. Subjects were randomly divided into the following three treatment groups: Group 1 was treated with three 15-minute applications of hydrogen peroxide at 15% with titanium dioxide (Lase Peroxide Lite) that was light-activated (Light Plus Whitening Lase) with five cycles of 1 minute and 30 seconds each cycle, giving a total treatment time of 45 minutes; Group 2 was treated with three 10-minute applications of hydrogen peroxide at 35% (Lase Peroxide Sensy), activated by light (LPWL) same activation cycles than Group 1, with a total treatment time of 30 minutes; Group 3 was treated with only one application for 45 minutes of hydrogen peroxide at 35% (Whitegold Office) without light activation. Each subject underwent one session of bleaching on the anterior teeth according to the manufacturers' instructions. Dentin sensitivity was recorded with a visual analogue scale (VAS) at baseline, immediately after, and at 7 and 30 days after treatment using a stimulus of an evaporative blowing triple syringe for 3 seconds on the upper central incisors from a distance of 1 cm. A Kruskal-Wallis test followed by Mann-Whitney test was performed for statistical analysis. Results: All groups showed increased sensitivity immediately after treatment. Group 1 displayed less changes relative to baseline with no significant differences (P= 0.104). At 7 and 30 days after treatment, a comparison of VAS values indicated no significant differences between all groups (P= 0.598 and 0.489, respectively).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM:To evaluate the clinical and radiographic success of endodontic treatment in human primary teeth with necrotic pulp with and without radiographically visible furcal/periapical lesion treated with a calcium hydroxide (CH) and chlorhexidine (CHX) intracanal dressing. The tested hypothesis was that there is no difference in the clinical and radiographic success in primary teeth medicated with CH pastes prepared with polyethylene glycol (PEG) or CHX.METHODS:Thirty-two teeth with necrotic pulp were used in this randomized clinical study: 12 without and 20 with lesion. Canals were prepared and medicated with CH pastes with polyethylene glycol (CH/PEG) (n=16) or 2% CHX gel (CH/CHX) (n=16). Definitive filling was done after 30 days. The teeth were clinically and radiographically examined during 12 months to determine the success of the endodontic therapy. Data from clinical and radiographic examination of the initial condition and 12 months after treatment were compared using the Z test (α = 0.05).RESULTS:There was no significant difference (p>0.05) in the success rate of teeth with and without lesion medicated with CH/PEG or CH/CHX. No significant difference (p>0.05) was found between the pastes regardless of the presence of lesion.CONCLUSIONS:Combination of CHX and CH was not more effective than the CH/PEG paste, as similar clinical and radiographic success rate was observed in teeth medicated with either type of intracanal dressing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the short-term response of human pulps to ethanol-wet bonding technique. Methods Deep class V cavities were prepared on 17 sound premolars and divided into three groups. After acid-etching, the cavities from groups 1 (G1) and 2 (G2) were filled with 100% ethanol or distilled water, respectively, for 60 s before the application of Single Bond 2. In group 3 (G3, control), the cavity floor was lined with calcium hydroxide before etching and bonding. All cavities were restored with resin composite. Two teeth were used as intact control. The teeth were extracted 48 h after the clinical procedures. From each tooth serial sections were obtained and stained with haematoxylin and eosin (H/E) and Masson's trichrome. Bacteria microleakage was assessed using Brown & Brenn. All sections were blindly evaluated for five histological features. Results Mean remaining dentine thickness was 463 ± 65 μm (G1); 425 ± 184 μm (G2); and 348 ± 194 μm (G3). Similar pulp reactions followed ethanol- or water-wet bonding techniques. Slight inflammatory responses and disruption of the odontoblast layer related to the cavity floor were seen in all groups. Stained bacteria were not detected in any cavities. Normal pulp tissue was observed in G3 except for one case. Conclusions After 48 h, ethanol-wet bonding does not increase pulpal damage compared to water-wet bonding technique. Clinical significance Ethanol-wet bonding may increase resin-dentine bond durability. This study reported the in vivo response of human pulp tissue when 100% ethanol was applied previously to an etch-and-rinse simplified adhesive system.