260 resultados para abutment screws
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.
Resumo:
Nowadays, the correction of skeletal vertical dysplasia is considered a great challenge in Orthodontics. The skeletal open bite treatment presents limitations related to vertical growth pattern, the extension of open bite and especially the stability, which is very questioned. The treatment of skeletal open bite is mostly realized by the inhibition of vertical alveolar posterior development (relative intrusion) or absolute intrusion of posterior teeth, through vertical forces, generated by the action of masticatory muscles. The purpose of this article is to present a new appliance for the treatment of skeletal open bite, the VABB (Vertically Activated Bite Block) or modified Bite Block, whose action mechanism is to limit the vertical development of the molars, by the action of facial muscles and two bilateral expansion screws that provide a counterclockwise rotation of the mandible. It will also be presented a clinical case and the technical steps for the construction of this appliance.
Resumo:
Osteodistraction is a clinical reality, available in the last decades for the resolution of large bone deficiencies, in cases that there are pre-existing, but misplaced implants and teeth. The aims of thearticle is to present a case report in which a new possibility for bone distraction, based on tooth-implant bone distractors, made from standard orthodontic expansion-screws, was used in an area where there was an extensive need of alveolar bone and aesthetical recovery, allied to teeth and dental implant misplacement. This technique presented good clinical results, associated to effective simplicity and low cost, becoming viable clinical solution for bone tissue augmentation and aesthetical optimization. In resume, it is possible to say that the suggested technique achieved its objectives, improving the hard and soft tissue profile, whilst allowing completion of oral rehabilitation.
Resumo:
The purpose of the study was to use scanning electron microscopy and energy dispersive x-ray spectrometry to assess possible morphologic and chemical changes after performing double-insertion and pullout tests of implants of different shapes and surface treatments. Four different types of implants were used—cylindrical machined-surface implants, cylindrical double-surface–treated porous implants, cylindrical surface-treated porous implants, and tapered surface-treated porous implants—representing a total of 32 screws. The implants were inserted into synthetic bone femurs, totaling 8 samples, before performing each insertion with standardized torque. After each pullout the implants were analyzed by scanning electron microscopy and energy dispersive x-ray spectrometry using a universal testing machine and magnified 35 times. No structural changes were detected on morphological surface characterization, only substrate accumulation. As for composition, there were concentration differences in the titanium, oxygen, and carbon elements. Implants with surface acid treatment undergo greater superficial changes in chemical composition than machined implants, that is, the greater the contact area of the implant with the substrate, the greater the oxide layer change. In addition, prior manipulation can alter the chemical composition of implants, typically to a greater degree in surface-treated implants.
Resumo:
Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: Trying to provide more anatomical data to the oral and maxillofacial surgeons regarding to orthognathic surgery, specifically about sagittal split osteotomy, the authors accomplished an anatomical study in dry human jaws, measuring the thickness in four previously established points of the body and mandibular ramus, at the usual spots used for the internal fixation by screws. Material and Methods: The authors also use the data collected to evaluate if there are significant differences between the group I (human dry mandibles with teeth) and group II (edentulous human dry mandibles). Results: For the group I the authors found the following results: x1 = 14,48, x2 = 14,94, x3=12,82 and x4 = 9,41, being the x2 the thickest point, and the least thick the x4. However in the group II, the found medium values were: x1 = 13,38, x2 = 13,08, x3 = 11,63 and x4 = 12,18, being the thickest point in that group the x1 and the least thick x3. The coefficient of simple correlation between the variables (group I and II) revealed a value of 0,6194, being this difference no significant at the meaning level of 95%.
Resumo:
The aim of this study was to evaluate in vitro the sealing ability of the root canal using different techniques: cold lateral compaction, modified Hybrid Tagger, Thermafil and System B. Material and methods. Were used 116 human single-roots, included in resin blocks, sectioned longitudinally, attached to a device with screws and divided into four groups (n=29). After instrumentation using a bur, depression was made in each third of the root canal in each of the halves. Teeth were filled upon the different techniques. For evaluation of the quality, pictures were taken with a 1.5X magnification, photos and radiographs were utilized. After statistical analysis, were performed both macroscopic and radiographic evaluation, by Chi-square test (χ2). Results. The Thermafil technique showed better results in terms of sealing capacity, failures and homogeneity followed by modified Hybrid Tagger, the System B and cold lateral compaction. Conclusions. Thermafil was the technique that shown to be macroscopic, radiographic and homogeneously best over the other techniques evaluated in regard to the filling of the depressions made (AU)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.