239 resultados para Teste tuberculínico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was conducted to determine the optimal time for collecting the breath examination urea breath marked with the stable isotope 13C. We selected patients before undergoing the examination of endoscopy at the Endoscopy Section of the University Hospital of Botucatu - SP. A screening was performed to determine which patients wanted and could participate. Before performing endoscopy basal sample was collected from the patient and then the labeled urea ingested. The blows were collected in double every 2.5 minutes until an interval of 30.0 minutes after were collected every 5.0 minutes until the time of 45.0 minutes . The samples were analyzed in a mass spectrometer for isotope ratio, located in the center of Stable Isotopes, Institute of Biosciences, UNESP - Botucatu campus. The data were studied and arranged in the form of graphics to better interpretation of results. Based on the obtained results it was determined that a standby time of 15.0 minutes to collect the wind is sufficient for accurate diagnosis and effective

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article aims to describe the proposed development of an emulator application for digital TV that operates on a local computer network, to have it as a testing environment for students and researchers. The emulator application is presented as a useful tool to reduce validation costs of applications developed for digital TV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correct distinguishment of microorganisms involved in the periodontal disease pathogen, it is important in the understanding of its progression and adequate treatment planning. Considering this fact, some molecular methods of identification and quantification were developed and are extremely sensitive and precise in the characterization of different bacteria species. The present study aimed to realize a literature review, including studies that realized a comparative analysis between bacterial culture and real time PCR methods in the identification of pathogens. The bacterial culture method can possibly identify new microorganisms and realize antibiotics sensitivity tests. The real time PCR is a microbiologic test that identifies and quantifies bacterial species, through gene amplification of predetermined DNA fragments, with high sensitivity and specificity, and need a shorter operation time of the operator when compared to the bacterial culture method. In this way, to determine a specific diagnostic test, should be considered not only its precision in the identification of microorganisms, but the cost-benefit relationship as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to estimate the reliability of the alcohol use disorders identification test (AUDIT) applied to adolescents. Evaluations were performed with 141 students of ages ranging from 14 to 17 years (14.93±0.62). The internal consistency of the instrument was estimated by Cronbach’s alpha coefficient and its reproducibility by weighted Kappa statistics by score and by a reliability interval of 95%. The AUDIT presented excellent internal consistency (α=0.80, rinter-item=0.29). Most questions present reproducibility ranked as “good”. It is concluded that the AUDIT is a reliable instrument to survey information about alcohol use in adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the standardization of the R-2 Non Verbal Intelligence Test for Children conducted at the city of Assis – SP, Brazil, and compares it with the São Paulo city standardization. The sample was composed by 559 children, between 5 and 11 years old, half of each sex, students from Assis city, randomly selected according to their proportion in private and public schools. Results indicate differences between ages and school types, but not between sexes. Percentile norms were established for the total sample at each age. The comparison of Assis and São Paulo city children reveals significant differences and Assis' results slightly higher. The conclusion is that R-2 Test is appropriate to cognitive assessment of Assis children, suggesting the use of new norms for this region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Estudos Linguísticos - IBILCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Um dos benefícios promovidos pelo exercício físico parece ser a melhora da modulação do sistema nervoso autônomo sobre o coração. No entanto, o papel da atividade física como um fator determinante da variabilidade da frequência cardíaca (VFC) não está bem estabelecido. Desta forma, o objetivo do estudo foi verificar se há correlação entre a frequência cardíaca de repouso e a carga máxima atingida no teste de esforço físico com os índices de VFC em homens idosos. MÉTODOS: Foram estudados 18 homens idosos com idades entre 60 e 70 anos. Foram feitas as seguintes avaliações: a) teste de esforço máximo em cicloergômetro utilizando-se o protocolo de Balke para avaliação da capacidade aeróbia; b) registro da frequência cardíaca (FC) e dos intervalos R-R durante 15 minutos na condição de repouso em decúbito dorsal. Após a coleta, os dados foram analisados no domínio do tempo, calculando-se o índice RMSSD, e no domínio da frequência, calculando-se os índices de baixa frequência (BF), alta frequência (AF) e razão BF/AF. Para verificar se existe associação entre a carga máxima atingida no teste de esforço e os índices de VFC foi aplicado o teste de correlação de Pearson (p < 0,05). RESULTADOS: Características demográficas, antropométricas, fisiológicas e carga máxima atingida no teste ergométrico: idade = 63 ± 3,0 anos; IMC = 24 ± 2kg/m²; FC = 63 ± 9bpm; PAS = 123 ± 19mmHg; PAD = 83 ± 8mmHg; carga máxima = 152 ± 29 watts. Não houve correlação entre os índices de VFC com os valores de FC de repouso e carga máxima atingida no teste ergométrico (p > 0,05). CONCLUSÃO: Os índices de variabilidade da frequência cardíaca temporal e espectrais estudados não são indicadores do nível de capacidade aeróbia de homens idosos avaliados em cicloergômetro.