237 resultados para Procedimentos cirúrgicos operatórios


Relevância:

20.00% 20.00%

Publicador:

Resumo:

On heat cured acrylic resins by microwaves energy the action of electromagnetic waves on methylmethacrylate promote the polymerization process. However, part of this energy is absorbed by the gypsum present in the flask and the function of this gypsum is to maintain the characteristics of specimen, nevertheless is unknown in the literature as the amount of water present in this gypsum affects the characteristics of acrylic resin. The proposal of this study was verified if dried gypsum influenced in some properties of the acrylic resins thermally activated by microwaves: presence of porosity, microhardness, roughness, flexural strength and dimensional change. Two different types of acrylic resin for complete denture were utilized: Lucitone 550 e Vipi-Wave and groups were formed: Lucitone 550, polymerization by microwave energy without gypsum treatment; Lucitone 550, polymerization by microwave energy with pretreatment gypsum; Vipi-Wave by microwave energy without gypsum treatment; Vipi Wave, polymerization by microwave energy with pretreatment gypsum; Lucitone 550 control group polymerization in hot water bath. For both situations were performed analysis of microhardness and porosity three different metallic shaped specimens were formed with followed dimensions: 2,0x2,0x2,0cm (8cm3); 2,0x2,0x1,0 (4cm3) e 2,0x2,0x0,5 (2cm3). Standardized wax specimens was used to prepare groups (n=9) and included in glass fiber flasks. The gypsum dry was made by microwave oven cycle (10min and 600W) and then the flasks were maintained in dry oven during two hours. Polymerizations of specimens were made and then polished. Wax patterns #7 obtained from the metal were embedded in plastic flask and following the processes of pressing and polymerization of the resin according to established groups. To evaluate the flexural strength, specimens 65mm x 10mm x 3.0mm from metallic patterns in bar format were made. ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundamentation: The correction of maxillary transverse deficiencies involves orthodontic and surgical procedures that can be performed before or after skeletal maturity. The surgically assisted rapid maxillary expansion (SAR ME) is performed by osteotomies through the lateral walls of the maxilla, zygomatic and canines buttresses, palatal and pterygomaxillary sutures, causing the maxillary disjunction. Followed by activation of the expander to the desired over-expansion in order to correct intercuspal later. Objective: The purpose of this study was to discuss the issues involved in the diagnosis of maxillary atresia, SAR ME indications, as well as surgical technique, through a case study. Methods: The male patient, 19 years old, had severe transverse maxillary deficiency with facial pattern III , Class III , with great lip incompetence. The patient underwent general anesthesia in a hospital environment, the osteotomies was done according to the technique described by Epker and Wolford (1980). Postoperatively, the patient underwent activations daily for 15 days and after 6 months, the orthodontist installed fixed orthodontic appliance to prepare the patient to orthognathic surgery later. Conclusion: The diagnosis by clinical evaluation and models study is essential for the indication of SAR ME and this procedure provides good predictability in the correction of transverse deficiency, with minimal morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The choice of surgical approach to diseases that affect the pre-auricular region has been subject of much discussion in the literature. Access pre-hearing, have been used with high compliance rate of success, and during the history of surgery, several modifications were made in this approach with the goal of reducing the irreversible consequences especially regarding common in condylar fractures as paralysis and facial scars. The views range from the indication of surgical treatment for all fractures, until the conviction that no fracture of the bone segment should be surgically treated. Therefore, this study is of relevance, since offers surgeons warn about the care on the anatomical structures involved in these surgical approaches and describe, seeking a comparison between them, the advantages of them by means of a literature review covering from the extensive bouts of Bellinger (1940) and Al-Kayat (1979) that provide a broad view of the surgical field to access modified and increasingly smaller as the endaural (2001) which not only allows a satisfactory field of aesthetics as maintenance the patient without any signs of scarring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To treat periodontal disease is essential to establish a control in all etiological factors that cause destructive activity in periodontal tissues. Basic periodontal therapy may be applied to eliminate or/and to control all etiologic factors involved in disease development. In this paper, some aspects to stabilize advanced periodontal disease using basic periodontal therapy are analyzed and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of his study was to review the current scientific literature in order to discuss the surgical, prosthetics and psychological/psychosocial aspects during the treatment planning of edentulous patients, when a total fixed prosthesis or overdenture is indicated. To identify studies to take part in this review, a search was conducted for the following databases: PubMed, Dentistry and Oral Sciences Source, Journals@Ovid, SpringerLink, Wiley Online Library, Nature (NPG), Oxford Journals. It was used as descriptors: total fixed prostheses and overdentures. Inclusion criteria were: clinical articles, clinical case reports, case series, literature reviews and systematic reviews that addressed the study and comparison of total fixed prostheses and overdentures for a surgical- prosthetic planning. Exclusion criteria were: laboratory and in vitro studies and those whose first language was not English or Portuguese. Of a total of 454 articles, after an analysis according to inclusion and exclusion criteria, 76 articles were selected. During an implantsupported prosthesis rehabilitation with dental in edentulous patients, the use of alternative procedures appear to be effective when compared to more invasive surgical techniques, and thus, the amount of dental implants possible to install associated with prosthetic issues such as lip support, smile line, quantity and quality of mucosa, phonetics, etc., will allow an appropriate treatment planning to each clinical case

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focus to apply, to discuss and to propose the Maximum Harvesting Method improvement, regarding the method application, for household rainwater harvesting systems. For this purpose, the rainwater was considered to supply the flush toilet demand in a household for 3, 4, and 5 inhabitants. The 80, 120 and 200m2 catchments areas and the 0, 1, 2 and 4mm first flushes discharges were also considered. Further, the improvement suggestions for cistern volume calculus and volume/level dynamics variation in a period were presented and the results were compared applying the Simulation Analyses Method. The results indicate that the Maximum Harvesting Method could be applied and that the improvement proposal can be used to determinate the cistern volume as well to analyze the dynamic behavior of volume/level, constituting by itself a single tool to assist rainwater harvesting systems designers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Educação Escolar - FCLAR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conjugal problems may damage parents and children relationships favoring the appearance of behavior problems, as well as causing psychological problems. Given the lack of studies which value several interrelated behavioral repertoires, the present paper aims at presenting assessment results employing multiple instruments in regards to the three couples that sought clinical services at a University clinic. Results indicated that participants were presenting communication deficits, problem solving difficulties, and problems in expressing affection confirming literature findings. Problems in other areas were also reported, which influenced the marital relationship. It stands out that the children were presenting indications of behavior problems. The relevance of data collection applying different instruments is discussed, and it is necessary that intervention programs consider individual difficulties, besides setting up singular objectives for each person searching for service.