244 resultados para Method Evaluation
Resumo:
This study aimed to evaluate the sensitiveness of the information obtained for the residual lignin from Eucalyptus grandis kraft pulps analyzed through the nitrobenzene oxidation, copper oxide (CuO) reduction and acidolysis techniques. The chips were cooked, resulting pulps of kappa number 14,5 and 16,9, respectively. Both lignins' pulps were evaluated through three methods (nitrobenzene oxidation, copper oxide oxidation and acidolysis). Then, they were subjected to an oxygen delignification stage. The 16,9 kappa number pulp resulted in higher levels of non-condensed lignin structures by the acidolysis method, higher syringyl/vanillin ratios (S/V) by the nitrobenzene and copper oxide methods and better performance in the oxygen delignification stage. The different methods allowed to differ the residual lignin pulps with kappa number 14,5 and 16,9, and the nitrobenzene oxidation method showed the highest sensitiveness in this study results.
Resumo:
Renal abscesses are rare in dogs and, although its pathogenesis is uncertain, may occur in diabetic patients with pyelonephritis, nephrolithiasis, kidney injuries or after abdominal surgery or kidney biopsy. Because of nonspecific clinical signs, laboratory tests associated with ultrasonography are important to confirm the diagnosis and treatment. Generally, kidney abscesses have sonographic aspects with different degrees of echogenicity such as hypo or hyperechoic, homogeneous or heterogeneous, and may or may not have thickened and hyperechoic walls, depending on its chronicity. Our objective was to report the use of ultrasound as a complementary method in the evaluation of disorders of the urinary tract, focusing on a case of renal abscess in a dog.
Resumo:
OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city. METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288) of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics. RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively. CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The surface of dental implants is an important factor for osseointegration process and different methods of surface treatment have been described. Objective: To investigate the bone apposition in implant surface treated with sandblasting and acid-etching. Material and methods: Ten rabbits were selected and received one implant treated with method I in the left tibia and one implant treated with method II in the right tibia. Then, twenty implants were divided in two groups, according to methods of sandblasting and acid-etching (method I and method II). After 7, 14, 30, 45 and 60 days, tibias were retrieved and submitted to histotechnical procedures. The percentages of bone–implant contact (BIC) and bone area between threads (BABT) were determined throughout histomorphometric analysis and bone apposition was detected in implants of both groups. Results: In BABT measurements, an increase was observed after 45 and 60 days in the method II, compared to method I and no differences were found after 7, 14 and 30 days. In BIC measurements, an increase was detected with method II at 45 days when compared to method I. No differences between groups in BIC values were observed after 7, 14, 30 and 60 days. Conclusion: Our data demonstrated that implants treated with the method II presented increase in the contact between bone and implant after 45 days compared to method I. Moreover, with concern to bone area between threads, it was observed an increased in the method II after 45 and 60 days. However, both groups can be successfully used as a therapeutic strategy to rehabilitation of edentulous patients. Then, further experiments are needed to evaluate, in depth, the putative differential role of each surface treatment.
Resumo:
The objective of this study was to present a systematized review of different methods used to evaluate the masticatory efficiency in conventional complete denture wearers. A survey was conducted in the databases PubMed, Scopus, and Cochrane, seeking scientific articles according to the previously selected terms: "Masticatory performance", "Masticatory efficiency" and "Chewing ability complete denture". Moreover, complementary studies have been carried out with library manual search/databases, which included studies related to different ways to assess masticatory efficiency, specifically as it related to conventional complete denture wearers. Forty three papers were selected to be used in the present review. Despite the wide variety of methodologies in the literature, the sieves method is currently considered the gold standard method to evaluation of conventional complete denture wearers masticatory efficiency, since it is the simplest, does not depend on specific devices (beyond the set of sieves), allows for a rational assessment, and it has been widely reproduced in various types of oral rehabilitation. More, the almond, as natural test food, and the optocal (made from the molding material Optosil), as artificial test food, are the most constantly employed test foods to evaluate masticatory efficiency.
Resumo:
Introduction: Alkalinization potential is a fundamental property of endodontic epoxy-based cements containing calcium hydroxide. Studies have shown discrepant pH results for same materials at different evaluation periods. A possible reason accounting for these differences may be the assessment procedures. Objective: To evaluate the pH value of an epoxy-based cement (Sealer 26) in different periods of analysis, using two assessment methods. Material and methods: Sealer 26 was manipulated and immediately placed into polyethylene tubes (n=10, each group) and immersed in distilled water. In G1, the tubes were kept in the same water during all experiment; and in G2, the tubes were removed and placed into another flask with an equal amount of water after the pH evaluation. The pH of these solutions was measured at 24 hours, 7, 14 and 28 days. Analysis were made within the same group according to the experimental periods and between groups in each experimental period. Data were submitted to ANOVA (α = 5%) and t test, respectively. Results: For G1 and G2, all periods showed different pH values (p < 0.05), except between 14 and 28 days (p > 0.05) and between 7 and 14 days (p > 0.05), respectively. In each period, no significant differences were observed between the groups. Conclusion: The method to obtain the pH values in different experimental periods no interfered in the final results. However, difference was observed when the results were analyzed at same group.
Resumo:
The aim of this study was to compare the efficacy of a direct clinical evaluation method with an indirect digital photographic method in assessing the quality of dental restorations. Seven parameters (color, occlusal marginal adaptation, anatomy form, roughness, occlusal marginal stain, luster, and secondary caries) were assessed in 89 Class I and Class II restorations from 36 adults using the modified US Public Health Service/Ryge criteria. Standardized photographs of the same restorations were digitally processed by Adobe Photoshop software, separated into the following four groups and assessed by two calibrated examiners: Group A: The original photograph displayed at 100%, without modifications (IMG100); Group B: Formed by images enlarged at 150% (IMG150); Group C: Formed by digital photographs displayed at 100% (mIMG100), with digital modifications (levels adjustment, shadow and highlight correction, color balance, unsharp Mask); and Group D: Formed by enlarged photographs displayed at 150% with modifications (mIMG150), with the same adjustments made to Group C. Photographs were assessed on a calibrated screen (Macbook) by two calibrated clinicians, and the results were statistically analyzed using Wilcoxon tests (SSPS 11.5) at 95% CI. Results: The photographic method produced higher reliability levels than the direct clinical method in all parameters. The evaluation of digital images is more consistent with clinical assessment when restorations present some moderate defect (Bravo) and less consistent when restorations are clinically classified as either satisfactory (Alpha) or in cases of severe defects (Charlie). Conclusion: The digital photographic method is a useful tool for assessing the quality of dental restorations, providing information that goes unnoticed with the visual-tactile clinical examination method. Additionally, when analyzing restorations using the Ryge modified criteria, the digital photographic method reveals a significant increase of defects compared to those clinically observed with the naked eye. Photography by itself, without the need for enlargement or correction, provides more information than clinical examination and can lead to unnecessary overtreatment.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Cell-dyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510) and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson's correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semi-automated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.
Resumo:
The information presented in this paper demonstrates the author's experience in previews cross-sectional studies conducted in Brazil, in comparison with the current literature. Over the last 10 years, auditory evoked potential (AEP) has been used in children with learning disabilities. This method is critical to analyze the quality of the processing in time and indicates the specific neural demands and circuits of the sensorial and cognitive process in this clinical population. Some studies with children with dyslexia and learning disabilities were shown here to illustrate the use of AEP in this population.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)