231 resultados para GROUP-4


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: This study evaluated the durability of bond strength to enamel using total-etch (Single Bond/SB) and self-etch (Clearfil SE Bond/CSEB) adhesives associated with neody-mium: yttrium-aluminu- garnet (Nd:YAG) laser irradiation through the uncured adhesives.Methods: Bovine incisors were worn to expose an area of enamel and were divided into four groups: group 1 (control) SB + polymerization; group 2 (control) CSEB + polymerization; group 3 (laser) - B + Nd:YAG laser (174.16 J/cm(2)) + polymerization; and group 4 (laser) CSEB + Nd:YAG (174.16 J/cm(2)) + polymerization. Blocks of composite were fabricated and stored for 24 hours or 12 months, sectioned into beams, and submitted to microtensile tests. Results were analyzed by three-way analysis of variance (ANOVA) (adhesive, technique, and storage time) and Tukey tests.Results: ANOVA revealed significant differences for adhesive 3 technique and technique 3 storage time (p<0.05). The mean values (MPa) for interaction adhesive x technique (standard deviation) were as follows: SB/control = 35.78 (6.04)a; SB/laser = 26.40 (7.25)b, CSEB/control = 26.32 (5.71)b, CSEB/laser = 23.90 (7.49)b. For interaction technique x storage time the mean values were as follows: control/24 hours = 32.58 (6.49)a; control/12 months = 29.52 (8.38)a; laser/24 hours = 29.37 (5.71)a; laser/12 months = 20.92 (6.5)b. Groups with the same letters showed no statistically significant differences.Conclusion: Scanning electron microscope analysis showed evident areas of micromorphological alterations in lased samples after 12 months of water storage. Nd: YAG laser irradiation of enamel through unpolymerized totaletch adhesive significantly reduced bond strength compared with the control. Bond strength decreased when enamel samples irradiated with Nd: YAG laser through unpolymerized adhesives were stored in water for 12 months.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: This study investigated the repairs of resin composite restorations after using different surface treatments.Design: Eighty four truncated cones of Filtek Z350 were prepared and thermo-cycled (20,000 cycles). Surfaces were roughened with diamond bur and etched with 37% phosphoric acid. Those cones were divided into 7 groups (N=12): 1) Prime&Bond 2.1; 2) aluminum oxide sandblasting+Prime&Bond 2.1; 3) Er:YAG laser treatment+Prime&Bond 2.1; 4) 9.6% hydrofluoric acid for 2 min-Fsilane coupling agent.; 5) silane coupling agent; 6) auto-polymerized acrylic monomer+Prime&Bond 2.1; 7) Adper Scothbond SE. Teflon device was used to fabricate inverted truncated cones of repair composite over the surface-treated. The bonded specimens were stressed to failure under tension. The data were analyzed with oneway ANOVA and Tukey tests.Results: Mean repair strengths (SD, in MPa) were, Group-2: 18.8a; Group-1: 18.7a; Group-6: 13.4ab; Group-7: 9.5bc; Group-3: 7.5bcd; Group-4: 5.2cd; Group-5: 2.6d.Conclusions: The use of diamond bur and a conventional adhesive and the use of aluminum oxide sandblasting prior to adhesive provided a simple and cost-effective solutions to composite repair. Er:YAG laser, silane alone, 9.6% hydrofluoric acid plus silane or a self-etching adhesive results in inferior composite repair strengths. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: skeletal muscles are dynamic tissue that can change their phenotypic characteristics providing a better functional adaptation to different stimuli. L-thyroxine is a hormone produced by the thyroid gland and has been used as an experimental model for stimulation of oxidative stress in skeletal muscle. Coenzyme Q10 (CoQ10) is a fat-soluble provitamin endogenously synthesized and found naturally in foods such red meat, fish, cereals, broccoli and spinach. It has antioxidant properties and potential in the treatment of degenerative and neuromuscular diseases. Objective: to evaluate the protective effect of CoQ10 in the soleus muscle of rats against the oxidative damage caused by L-thyroxine. Methods: the rats were divided in four groups of six animals each: Group 1 (control); Group 2 (coenzyme Q10); Group 3 (L-thyroxine), and Group 4 coenzyme Q10 and L-thyroxine). After euthanasia, blood was collected and serum activity of the enzymes creatine kinase (CK) and aspartate aminotransferase (AST) was analyzed. In the soleus muscle homogenates the factors related to oxidative stress were assessed. Results: CoQ10 protected the soleus muscle against the damage caused by L-thyroxine and favored the maintenance of the antioxidant enzymes glutathione reductase and glutathione peroxidase, the concentration of decreased and oxidized glutathione, and prevented lipid peroxidation. Conclusion: the results indicate that CoQ10 protects rat soleus muscle from oxidative damage caused by L-thyroxine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Twenty-four bitches which had been in labour for less than 12 hours were randomly divided into four groups of six. They all received 0(.)5 mg/kg of chlorpromazine intravenously as premedication, followed 15 minutes later by either 8 mg/kg of thiopentone intravenously (group 1), 2 mg/kg of ketamine and 0-5 mg/kg of midazolam intravenously (group 2), 5 mg/kg of propofol intravenously (group 3), or 2(.)5 mg/kg of 2 per cent lidocaine with adrenaline and 0(.)625 mg/kg of 0(.)5 per cent bupivacaine with adrenaline epidurally (group 4). Except for group 4, the bitches were intubated and anaesthesia was maintained with enflurane. The puppies' heart and respiratory rates and their pain, sucking, anogenital, magnum and flexion reflexes were measured as they were removed from the uterus. The puppies' respiratory rate was higher after epidural anaesthesia. in general the puppies' neurological reflexes were most depressed after midazolam/ketamine, followed by thiopentone, propofol and epidural anaesthesia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electromanometric measures of the gastroesophageal junction were performed in 20 adult, male and female, anesthetised opossums. The electromanometric examinations were performed according the intermitent pull through technique. The research was divided in four groups, according to the drug to be analysed: group 1 (20 animals) IM injection of physiological solution (control group); group 2 (20 animals) IM injection of metoclopramide; group 3 (20 animals) IM injection of ranitidine; group 4 (20 animals) IM injection of droperidol. Electromanometry was done 15 minutes before the drug injection, just after the injection and 15, 30, 45 and 60 minutes after the injection. In each one of the moments the pressure of the lower esophageal sphincter (LES-mmHg) was analysed. Considering LES pressure the results observed were: in group 1 it was not observed any significative alteration after IM injection of physiologic solution; in group 2 it was observed significative pressure increase, 15 minutes after metoclopramide IM injection; in group 3 it was observed pressure increase, being significative at 15 and 30 minutes after IM injection; in group 4 it was observed significative increase in LES pressure in every moment, 15 minutes after droperidol IM injection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of Er:YAG and Nd:YAG lasers on the shear bond strength of composite resin to dentin. The coronal portion of 56 human molars was divided into three parts, and the dentin thickness was standardized at 2 mm. A 3-mm hole was marked in the center of each tooth with sealing tape paper. The specimens (n = 14) were then divided into four groups: (1) acid etching + Single Bond (SB) (control), (2) acid etching + SB + Nd:YAG laser irradiation (before adhesive curing), (3) thermal etching with the Er:YAG laser + SB, and (4) thermal etching with the Er:YAG laser + SB + Nd:YAG laser irradiation (before adhesive curing). A composite resin cylinder was built into the delimited area for conducting the shear bond strength test on the universal testing machine. The means ± standard deviations were: group 1, 17.05 ± 4.15 MPa; group 2, 16.90 ± 3.36 MPa; group 3, 12.12 ± 3.85 MPa; and group 4, 12.92 ± 2.73 MPa. Groups 1 and 2 presented significantly higher values than groups 3 and 4. It was concluded that conventional etching with 37% phosphoric acid yielded significantly higher bond strength values compared to thermal etching with the Er:YAG laser. The Nd:YAG laser did not significantly influence the bond strength.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

New strategies to fulfill craniofacial bone defects have gained attention in recent years due to the morbidity of autologous bone graft harvesting. We aimed to evaluate the in vivo efficacy of bone tissue engineering strategy using mesenchymal stem cells associated with two matrices (bovine bone mineral and α-tricalcium phosphate), compared to an autologous bone transfer. A total of 28 adult, male, non-immunosuppressed Wistar rats underwent a critical-sized osseous defect of 5 mm diameter in the alveolar region. Animals were divided into five groups. Group 1 (n = 7) defects were repaired with autogenous bone grafts; Group 2 (n = 5) defects were repaired with bovine bone mineral free of cells; Group 3 (n = 5) defects were repaired with bovine bone mineral loaded with mesenchymal stem cells; Group 4 (n = 5) defects were repaired with α-tricalcium phosphate free of cells; and Group 5 (n = 6) defects were repaired with α-tricalcium phosphate loaded with mesenchymal stem cells. Groups 2-5 were compared to Group 1, the reference group. Healing response was evaluated by histomorphometry and computerized tomography. Histomorphometrically, Group 1 showed 60.27% ± 16.13% of bone in the defect. Groups 2 and 3 showed 23.02% ± 8.6% (p = 0.01) and 38.35% ± 19.59% (p = 0.06) of bone in the defect, respectively. Groups 4 and 5 showed 51.48% ± 11.7% (p = 0.30) and 61.80% ± 2.14% (p = 0.88) of bone in the defect, respectively. Animals whose bone defects were repaired with α-tricalcium phosphate and mesenchymal stem cells presented the highest bone volume filling the defects; both were not statistically different from autogenous bone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate the use of ropivacaine combined or not with different opioids, for epidural anesthesia in bitches submitted to elective ovariosalpingohisterectomy (OSH). Thirty two mixed-breed female dogs, adults were used with medium weigh of 10.5kg. The animals were premedicated with acepromazine (0.05mg.kg-1, IM) and midazolam (0.2mg.kg-1, IM) and allocated in four experimental groups: group 1(n=8): ropivacaine: 0.3 mL.kg-1; group 2(n=8): ropivacaine + morphine (0.1 mg.kg-1); group 3(n=8): ropivacaine + butorphanol (0.1 mg.kg-1); and group 4(n=8): ropivacaine + tramadol (0.5 mg.kg-1) administered epidurally. Heart and respiratory rate; systolic arterial pressure; rectal temperature; arterial blood gas partial pressures; blood pH; sedation and muscular relaxation degree were evaluated at different experimental moments. The data were submitted to ANOVA and compared by Kruskal Wallis, Friedman, Dunn, Tukey and Chi-square test (p≤0.05). Minimum cardiorespiratory alterations were observed and the group of the ropivacaíne combined with the butorphanol (G3) presented a more cranial blockage, what allowed the accomplishment of OSH without induction in six animals (75%) whereas most of the others needed anesthetic rescue. The results allow us to conclude that the use of ropivacaine sole or combinated with morphine, butorphanol or tramadol, for epidural anesthesia, didn't promote significant cardiorrespiratory depression and the ropivacaine associated to the butorphanol allowed the accomplishment of OSH in bitches.