307 resultados para Esthetic.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This clinical report describes an adult patient referred for orthodontic treatment with mini-implants as anchorage to correct the root angulation of maxillary lateral incisors. The purpose of this report was to demonstrate the versatility of mini-implants placed in a vertical direction in esthetic areas. During orthodontic treatment, some aspects must be observed to preserve the interim restoration against the occlusal loads to avoid screw fracture. A fixed appliance was placed to correct the position of the maxillary anterior teeth and to complete the treatment. Acceptable esthetics and function were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novos compósitos têm surgido no mercado especificamente destinados à confecção de restaurações estéticas posteriores. Entretanto, embora tais materiais apresentem resultados iniciais animadores, há a necessidade de comprovações adicionais para que possam ser utilizados com segurança. Resinas compostas posteriores são submetidas a estresses complexos de compressão e abrasão durante a mastigação e a aplicação de selantes superficiais tem sido relatada como forma de aumentar a resistência ao desgaste destes materiais. O presente trabalho teve como propósito avaliar a dureza e a resistência à compressão das resinas compostas Alert (Jeneric/Pentron), Ariston (Vivadent), Definite (Degussa), P60 (3M), Solitarie (Kulzer), Surefil (Dentsply) e Z100 (3M) após 90 dias de imersão em água destilada, recobertas com selante Protect It (Jeneric/Pentron) e submetidas à ciclagem mecânica (10.000 ciclos, 600N, 5Hz). Os ensaios de dureza (n=8) foram realizados em aparelho Wolpert, com diamante Vickers e peso de 50gf aplicado por 30 segundos, antes e após períodos de imersão de 30, 60 e 90 dias. Os ensaios de resistência à compressão (n=8) foram realizados somente após 90 dias, em corpos-de-prova cilíndricos medindo 8mm de altura por 4mm de diâmetro. Apenas os espécimes destinados à compressão foram ciclados mecanicamente. Os ensaios foram realizados em máquina MTS 810, equipada com célula de carga de 10kN (ciclagem) e 100kN (compressão) e velocidade de 0,5mm/min. Após análise de variância (p<0,05), os resultados mostraram, previamente à imersão, maiores valores de dureza para os materiais Z100 (74,253VHN) e Ariston (71,308VHN). A seguir, com valor semelhante à resina Ariston, mas inferior à resina Z100, apresentou-se o material Surefil (69,969VHN)...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recentemente, foram lançados no mercado odontológico novos materiais estéticos para restaurações diretas em dentes posteriores, aos quais são atribuídas propriedades mais adequadas para essa indicação. Entretanto, as informações disponíveis são ainda muito escassas, gerando dúvidas quanto à sua real eficácia, sobre quais as diferenças de suas composições e propriedades físicas e mecânicas em relação aos materiais até então disponíveis e se, de fato, apresentam melhor performance clínica. Em vista do exposto, nos propusemos a estudar contração de polimerização, resistência à flexão e concentração de partículas inorgânicas, por massa e volume, de sete resinas compostas (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 e Tetric Ceram). A contração de polimerização foi medida nos materiais inseridos em um anel plástico, e o registro das alterações, durante a polimerização, foi feito por meio de instrumento eletrônico de medida linear, que registra as alterações dimensionais, com sensibilidade de 1 mm. A resistência à flexão foi medida na máquina de ensaios mecânicos MTS 810 e a confecção dos corpos-de-prova e dos dispositivos para o ensaio foi orientada pela norma ISO no 4049:1988. A determinação do conteúdo de partículas inorgânicas por massa foi feita através da pesagem de uma porção de resina composta polimerizada antes e após a eliminação da fase orgânica em forno, à temperatura de 700oC. O porcentual volumétrico de partículas inorgânicas foi calculado com base no Princípio de Arquimedes. Foi determinado o volume da resina composta polimerizada, antes e após a eliminação da fase orgânica, pela diferença da massa do material pesado ao ar e imerso em água. Os dados de conteúdo de partículas inorgânicas por massa e por volume, de contração de polimerização e resistência à flexão foram submetidos...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The general aim of this article is to describe the state-of-the-art of biocompatibility testing for dental materials, and present new strategies for improving operative dentistry techniques and the biocompatibility of dental materials as they relate to their interaction with the dentin-pulp complex.Methods. The literature was reviewed focusing on articles related to biocompatibilty testing, the dentin-pulp complex and new strategies and materials for operative dentistry. For this purpose, the PubMed database as well as 118 articles published in English from 1939 to 2014 were searched. Data concerning types of biological tests and standardization of in vitro and in vivo protocols employed to evaluate the cytotoxicity and biocompatibility of dental materials were also searched from the US Food and Drug Administration (FDA), International Standards Organization (ISO) and American National Standards Institute (ANSI).Results. While there is an ongoing search for feasible strategies in the molecular approach to direct the repair or regeneration of structures that form the oral tissues, it is necessary for professionals to master the clinical therapies available at present. In turn, these techniques must be applied based on knowledge of the morphological and physiological characteristics of the tissues involved, as well as the physical, mechanical and biologic properties of the biomaterials recommended for each specific situation. Thus, particularly within modern esthetic restorative dentistry, the use of minimally invasive operative techniques associated with the use of dental materials with excellent properties and scientifically proved by means of clinical and laboratory studies must be a routine for dentists. This professional and responsible attitude will certainly result in greater possibility of achieving clinical success, benefiting patients and dentists themselves.Signcance. This article provides a general and critical view of the relations that permeate the interaction between dental materials and the dentin-pulp complex, and establish real possibilities and strategies that favor biocompatibility of the present and new products used in Dentistry, which will certainly benefit clinicians and their patients. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of the functional and esthetic requirements of patients, different techniques have been proposed to reduce the time between dental implant placement and interim restoration fabrication. This article describes a modified indexing technique by using a surgical template for open-tray impression and definitive cast development during immediate loading procedures. This technique does not use a complete impression of the oral cavity and, therefore, is more comfortable, less time consuming, and less expensive. It also allows the fabrication of interim restorations with the optimal shape for developing an adequate emergence profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The correction of diastemas in the anterior region with composite resin is considered to be practical and conservative. Harmony between the restorative material and the periodontium is necessary to achieve satisfactory functional and esthetic results. Whenever excessive gingiva occurs in the interproximal region, removal is necessary to avoid excessively contoured restorations. A predictable technique is described to conservatively remove interproximal tissue in situations in which crown lengthening is required to treat bilateral diastemas. A surgical template based on the diagnostically waxed cast was produced to serve as a reference during periodontal surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study aimed to investigate the influence of ceramic thickness and shade on the Knoop hardness and dynamic elastic modulus of a dual-cured resin cement.Materials and Methods: Six ceramic shades (Bleaching, A1, A2, A3, A3.5, B3) and two ceramic thicknesses (1 mm, 3 mm) were evaluated. Disk specimens (diameter: 7 mm; thickness: 2 mm) of the resin cement were light cured under a ceramic block. Light-cured specimens without the ceramic block at distances of 1 and 3mm were also produced. The Knoop hardness number (KHN), density, and dynamic Young's moduli were determined. Statistical analysis was conducted using ANOVA and a Tukey B rank order test (p = 0.05).Results: The bleaching 1-mm-thick group exhibited significantly higher dynamic Young's modulus. Lower dynamic Young's moduli were observed for the 3-mm-thick ceramic groups compared to bleaching 3-mm-thick group, and no difference was found among the other 3-mm groups. For the KHN, when A3.5 3-mm-thick was used, the KHN was significantly lower than bleaching and A1 1-mm-thick ceramic; however, no difference was exhibited between the thicknesses of the same shade.Conclusions: The dual-cured resin cement studied irradiated through the 1-mm-thick ceramic with the lightest shade (bleaching ceramic) exhibited a better elastic modulus, and there was no effect in KHN of the resin cement when light cured under different ceramic shades and thicknesses (1 and 3 mm), except when the A3.5 3-mm-thick ceramic was used.Clinical Significance: Variolink II irradiated through ceramic with the lowest chroma exhibited the highest elastic modulus; therefore, the light activation method might not be the same for all clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autogenous bone grafting is the gold-standard technique for bone augmentation procedures prior to implant placement. If the amount of available intraoral donor bone is insufficient, it is necessary to harvest bone graft from extraoral sites, such as calvaria. Although this technique is well established, only a few case reports show the histological analysis of the grafted bone at the moment of implant placement. This article reports the case of a 48-year-old female patient with a critical atrophic maxillary ridge reconstructed using autogenous calvarial bone graft prior to implant placement, with clinical and histological evaluation. Bone was collected under general anesthesia from the parietal bone. The outer cortical originated the bone blocks, and the medullar bone layer between was collected to be used in the sinus augmentation procedure, together with 5 of the bone blocks triturated. Six months after bone augmentation, 8 implants were placed in the grafted area and 2 biopsies were retrieved (anterior and the posterior regions), allowing the visualization of the bone-remodeling process in the grafted areas. The patient had a stable recovery. Our results showed that although necrotic bone could still be seen in the outer layer of the grafted area, the interface between this necrotic bone and the already remodeled bone was consistent with biocompatibility. Two-year radiographic evaluation showed success of the grafts and the implants in supporting an esthetic and functionally stable prosthesis. Summarizing, calvarial bone grafts are a viable alternative for the attainment of adequate bone volume prior to implant placement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crescent increasing demand of the electric power in Brazil has stimulated the implantation of Small Central Hydroelectric Power (SCHP) in several regions of the country. However, the silting up of the reservoirs is one of the main problems faced by hydroelectric power plants and SCHP. In this context, this research aimed evaluate the phenomenology and propose the enforcement of appropriate bioengineering techniques to control the intense erosive process of the hydrographical basin of the “Alto Rio Sucuriú,” that cause silting up of the reservoirs of the SCHP Costa Rica, located in the municipal district of Costa Rica (MS). In order to identify the phenomenology of the main falling in of this basin, a diagnosis of the conditions of the physical environment of the region (climate, geology, pedology, hydrology, and use of the ground) was realized. A surveying was also realized to specify the geometric feature of the falling in using the Total Station of the Ruide brand, series RTS 860R and the geodetic GPS of the Ashtech brand and the data obtained was used on the preparation of the Digital Elevation Model (DEM) of the falling in. Based on this diagnosis an official register of the falling in was done with identification of the different types of present erosion. Due to the advanced erosive stage of the falling in researched, the use of bioengineering techniques could be the best solution considering that the traditional engineering techniques make use of heavy material like concrete, iron and large machines that besides causing higher impact to the natural and esthetic aspects of the environment also require a higher investment of capital. This research establish a great cooperation to the knowledge of the erosive process and of the rehabilitation of the degraded areas with application of bioengineering techniques not only hydrographical basin of “Alto Rio Sucuriú” but also to other basins that show similar situation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photodynamic Therapy (PDT) is a technique used to treat several types of lesions, such as cancer, microbial control, and esthetic dentistry cases. The performance of PDT involves the use of a photosensitizer (PS), which mainly will be located in cancer cells and is irradiated with visible light. This process, when it occurs in the presence of oxygen triggers the formation of reactive oxygen species that are cytotoxic to cells. These species cause cell death and subsequent tumor necrosis. The use of white light as a light source for multispectral Photodynamic Therapy and its consequences to the photodynamic effect is not yet completely established, and therefore there is interest in studying the parameters involved for analyzing the best conditions for applying treatment. The wavelength is crucial to improve the therapeutic effect, since both the optical properties of the biological tissue as the PS depend on these parameters. For FS studied in this work (Photogem®) are most often used wavelengths in the red region, due to their larger penetration depth in biological tissue. Thus, the light source becomes a fundamental aspect, their choice depends on the specific application and is based on the tumor location, light dose to be delivered and FS chosen. Despite all the advantages presented by lasers, the fact of having an emission spectrum essentially monochrome makes only one possible transition possible for the absorption of FS is used. Therefore, more extensive light sources such as light emitting diodes (LED), could be better used in some cases the laser, with the additional advantage of a reduced cost. Therefore, the choice of the white LED comes from an emission spectrum that still wider LED colors defined by allowing greater use of the several absorption bands and with varying depths of operation, according to the wavelength... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The automobile industry is increasingly interested in reducing vehicle weight for greater speed, lower fuel consumption and emissions, through innovation of materials and processes. One way to do this is to seek the replacement of conventional processes by the use of structural adhesives. Structural adhesives are highly resistant materials, which can replace rivets, bolts and welds allowing the substrate / adhesive assemble is stronger than the substrate itself. One of the major advantages of gluing with respect to welding is its esthetic appearance, since it does not leave marks. For this reason, parts to be soldered require a minimum thickness so that the marks do not appear, since the pieces from gluing have no restriction as to the thickness. By replacing the vibration welding process for gluing process of the instrument panel parts of an automobile, one obtains a reduction of the thickness of the parts and therefore it decreases the weight of the car. This work aims to study the various structural adhesives that already exist on the market to be applied on the instrument panel. The mechanical test performed to measure the maximum adhesive strength was the Lap Shear Test at 23°C (room temperature), -35°C and 85°C. The types of adhesives used were the hot-melt and the bi-component. By the results obtained, it is in favor using the bi-component for application to the union of instrument panel parts