236 resultados para DISINFECTION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. OBJECTIVE: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. MATERIAL AND METHODS: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey's test. The level of significance was set at P < 0.05. RESULTS: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. CONCLUSION: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. Objective: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. Material and methods: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey’s test. The level of significance was set at P < 0.05. Results: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. Conclusion: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development and maintenance of periapical lesion occurs as a result of bacterial infection of the root canal system. Faced with the failure of endodontic treatment, retreatment is the first option with great potential for success, when performed with proper disinfection of the root canal system. Case report: Patient aged 39 years needing dental care show at clinical examination moderate gingival bleeding in the region of tooth 22 and the presence of radiographic periapical bone rarefaction due to unsatisfactory endodontic treatment. It was indicated the endodontic retreatment. We performed procedures to remove the filling material, root canal preparation using manual and mechanical techniques and completion with the use of root canal medication based on calcium hydroxide. After root canal filling, clinical and radiographic success were demonstrated for the case. Conclusion: We conclude that the non-surgical retreatment with disinfection and proper use of medication to the base of calcium hydroxide promoted success after outcome monitoring for 2 years and 8 months (AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection; Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the ability of low time microwaveexposureto inactivate and damage cell membrane integrity of C. albicans. Materials and Methods: Two 200ml C. albicans suspensions were obtained. Sterile dentures were placed in a beaker containing Experimental (ES) or Control suspensions (CS). ES was microwaved at 650 W for 1, 2, 3, 4 or 5 min. Suspensions were optically counted using Methylene blue dye as indicative of membrane-damaged cells; spread on Agar Sabouraud dextrose (ASD) for viability assay; or spectrophotometrically measured at 550nm. Cell-free solutions were submitted to content analyses of protein (Bradford and Pyrogallol red methods); Ca++ (Cresolphthalein Complexone method); DNA (spectrophotometer measurements at 260nm) and K+ (selective electrode technique). Data were analyzed by Student-t test and linear regression (α=0.05). In addition, flowcytometry analysis of Candida cells in suspensionwas performed using propidium iodide. Results: All ES cells demonstrated cell membrane damage at 3, 4 and 5 min,viable cells were nonexistent at 3, 4 and 5 min ES ASD plates and optical density of ES and CS was not significantly differentfor all exposition times. ES cells released highcontents of protein, K+ , Ca++ and DNA after 2 min exposition when compared to that of the CSs. Similar results were observed with flow cytometry analysiswith regard to the periodsof microwave exposure. Conclusions: Microwave irradiation inactivated C. albicansafter 3min and damaged cell membrane integrity after 2 min exposition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water disinfection usually requires expensive chemicals or equipment. Chlorination is a common disinfection method, although it is not able to inactivate all pathogens. High concentrations of residual chlorine also cause an unpleasant taste and smell in drinking water. As an alternative, photocatalysis and photoelectrochemical treatment has a high disinfection potential in drinking water by using solid catalysts, such as titanium dioxide. Highly reactive hydroxyl radical generated during the process serves as the main oxidant, capable of inactivating a wide range of microorganisms. In this study, we proposed a novel comparison between Gram-positive and gram-negative microorganisms. An immobilized TiO2 film promoted higher efficiency in water disinfection processes. The treatment effectively inactivated Escherichia coli and Staphylococcus aureus bacterial microorganisms in a shorter period than other alternative methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Antibiotic-containing polymer-based nanofibers (hereafter referred to as scaffolds) have demonstrated great potential for their use in regenerative endodontics from both an antimicrobial and cytocompatibility perspective. This study sought to evaluate in vitro the effects of ciprofloxacin (CIP)-containing polymer scaffolds against Enterococcus faecalis biofilms. Methods: Human mandibular incisors were longitudinally sectioned to prepare radicular dentin specimens. Sterile dentin specimens were distributed in 24-well plates and inoculated with E. faecalisfor biofilm formation. Infected dentin specimens were exposed to 3 groups of scaffolds, namely polydioxanone (PDS) (control), PDS + 5 wt% CIP, and PDS + 25 wt% CIP for 2 days. Colony-forming units (CFU/mL) (n = 10) and scanning electron microscopy (SEM) (n -= 2) were performed to quantitatively and qualitatively assess the antimicrobial effectiveness, respectively. Results: PDS scaffold containing CIP at 25 wt% showed maximum bacteria elimination with no microbial growth, differing statistically (P < .05) from the control (PDS) and from PDS scaffold containing CIP at 5 wt%. Statistical differences (P < .05) were also seen for the CFU/mL data between pure PDS (5.92-6.02 log CFU/mL) and the PDS scaffold containing CIP at 5 wt% (5.39 5.87 log CFU/mL). SEM images revealed a greater concentration of bacteria on the middle third of the dentin specimen. after 5 days of biofilm formation. On scaffold exposures, SEM images showed similar results when compared with the CFU/mL data. Dentin specimens exposed to PDS + 25 wt% CIP scaffolds displayed a practically bacteria-free surface. Conclusions: On the basis of the data presented, newly developed antibiotic-containing electrospun scaffolds hold promise as an intracanal medicament to eliminate biofilm/infection before regenerative procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to avoid that contaminated frog farms animals escaping in the environment and become potential vector of emergent diseases, studies with disinfection protocol are strictly necessary. The formaldehyde is one of the compounds tested in fungal disinfection protocols and also used in aquaculture. This study aimed to determine the median lethal concentration (LC50-96h) of formaldehyde in bullfrog tadpoles and to evaluate the possible genotoxic effects in acute exposition. Accordingly, the animals were exposed to formaldehyde in the concentrations of 6, 9, 12, 15, and 18 mg L(-1), and after 96 h blood samples were drawn for the micronucleus (MN) test. The LC50-96h was 10.53 mg L(-1), and the MN frequency increased in proportion to the formaldehyde concentrations, with an estimated frequency in the negative control being 1.35 MN/individual. We concluded that formaldehyde is genotoxic to tadpoles of bullfrogs in the tested concentrations, and the choice of this chemical should be contemplated before its use in animals in captivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT