215 resultados para screw
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10,12.5, 15 mm crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-Dmodels. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metalceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200 N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises'criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maxiinum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio = 30.1% and C/I 1:1 to 1 :1.5 ratio = 46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio = 30% and C/I 1:1 to 1:1.5 ratio = 51.5%). (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Reconstrução imediata de fenestração peri-implantar com enxerto autógeno em bloco de ramo mandibular
Resumo:
Alveolar wall fenestrations are common during implant placement. The aim of this paper is to report a case where a peri-implant bone fenestration was reconstructed immediately after implant placement by an autogenous mandibular bone block. A male patient was referred to the Department of Surgical and Integrated Clinics to substitute his Kennedy´s Class IV removable partial denture for an implantsupported fixed prosthesis. A peri-implant bone fenestration at the buccal wall was seen at the region of 12, being reconstructed by a mandibular bone block secured by a bicortical screw. Six months later the surgical procedures, an implant-supported complete fixed partial prosthesis was developed. The autogenous bone block harvested from the mandibular ramus was a safe alternative to reconstruct the peri-implant bone defect such as fenestration types.
Resumo:
The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.
Resumo:
Purpose: The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. Materials and Methods: Computer-aided design software was used to create 32 finite element models of an atrophic posterior partially edentulous mandible with a single external-hexagon implant (5 mm wide × 7 mm long) in the first molar region. Finite element analysis software with a convergence analysis of 5% to mesh refinement was used to evaluate the effects of C/I ratio (1:1; 1.5:1; 2:1, or 2.5:1), prosthetic retention system (cemented or screwed), and restorative material (metal-ceramic or all ceramic). The crowns were loaded with simulated normal or traumatic occlusal forces. The maximum principal stress (σmax) for cortical and cancellous bone and von Mises stress (σvM) for the implant and abutment screw were computed and analyzed. The percent contribution of each variable to the stress concentration was calculated from the sum of squares analysis. Results: Traumatic occlusion and a high C/I ratio increased stress concentrations. The C/I ratio was responsible for 11.45% of the total stress in the cortical bone, whereas occlusal loading contributed 70.92% to the total stress in the implant. The retention system contributed 0.91% of the total stress in the cortical bone. The restorative material was responsible for only 0.09% of the total stress in the cancellous bone. Conclusion: Occlusal loading was the most important stress concentration factor in the finite element model of a single posterior crown supported by a short implant.
Resumo:
The aim of this study was to evaluate the influence of implant angulation and abutment type (UCLA and Estheticone) on stress distribution in screw-retained implant-supported prostheses through photoelasticity. Three models were fabricated with photoelastic resin PL-2 (Vishay, Micro-Measurements Group, Inc Raleigh, N.C., USA) containing one external hexagon implant with 3.75x10mm (Master screw, Conexão Sistemas de Prótese Ltda., Arujá, São Paulo) with 0°, 17° and 30° degrees and a screw-retained prostheses with UCLA and Estheticone abutments. The assembly was positioned in a circular polariscope; axial and oblique (45° degrees) loads of 100N were applied in fixed points on the occlusal crown surfaces by a universal testing machine. The stress generated was photographed and analyzed qualitatively with appropriate software (Adobe Photoshop®). The results demonstrated the same number of fringes for both abutment types for each angulation, with fringes increasing in the same way. A higher number of fringes were closer in the oblique loading mode. It was concluded that there was no significant difference in stress distribution in prostheses with UCLA and Estheticone abutments. Higher stress concentrations were observed with increased implant angulation. Stress concentration and intensity were higher in the oblique load than in axial load application.
Resumo:
In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.
Resumo:
Background Dentoalveolar trauma, especially when involving front teeth, negatively affect the patient’s life; in particular, tooth avulsion is a complex injury that affects multiple tissues, and no treatment option offers stable long-term outcomes. The aim of this study was to report a case of reconstruction of atrophic anterior alveolar ridge after tooth loss, performed with autograft harvested from the chin, and subsequent prosthetic rehabilitation with the use of an osseointegrated implant. Case report A 23-years-old Caucasian girl, presented an atrophic alveolar bone in the area of tooth 11, as a result of tooth resorption 10 years after a tooth reimplantation procedure. Reconstruction was performed with autogenous bone harvested from the chin. After 6-months healing period to allow autograft incorporation, a dental implant was inserted. After further 6- months, a screw-retained implant supported metal-ceramic prosthesis was fabricated. Results The prosthetic rehabilitation was successful, and after a follow-up period of 5 years, the achieved result was stable.Conclusion It can be concluded that the autogenous bone graft harvested from the chin, is a safe and effective option for alveolar ridge defects reconstruction, allowing a subsequent placement of a dental implant supporting a prosthetic restoration.
Resumo:
Dentoalveolar traumatisms, particularly those that affect the anterior teeth, interfere adversely in the patient s life.Among them, tooth avulsion is pointed out because it is characterized as a complex injury that affects multiple tissues, andbecause there is no effective treatment available for its resolution with a stable long-term outcome.Aim/Hypothesis: The aim of the present study was to relate a clinical case of complete reconstruction of atrophy of the alveolarbone corresponding to tooth 11, lost by tooth resorption 10 years after the tooth reimplantation procedure.Material and methods: Reconstruction was performed with autogenous bone harvested from the mentum donor site. Surgicalaccess began in the receptor area with a Newman mucoperiosteal incision using a scalpel blade 15 mounted in a scalpel handlefor detachment and exposure of the receptor site. Extensive bone resorption was observed in the vestibular-palatine direction,proved by the thinness of the receptor bed. Decorticalization of the vestibular bone plate was performed. After preparing thereceptor bed, and incision was made in the mucosa in the depth of the anterior vestibular fornix, then a perpendicular muscleperiostealincision to detach and exposure the donor area. The bone graft necessary for reconstruction of the donor area wasdelimited, followed by monocortical osteotomy and the monocortical graft was removed. The next stage was to perform shapingfor passive graft accommodation and fixation by means of two bicortical screws. After fixation of the graft the sharp angles wererounded off in order to avoid possible exposure and/or fenestrations of the reconstructed area, then the receptor and donor areawere sutured. After the 6-month period to allow incorporation of the autogenous graft, an osseointegrated dental implant wasinserted. At the end of the 6-month period of waiting for osseointegration to occur, the process of fabricating the screw-retainedmetal ceramic
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)