212 resultados para correlation interferometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity detection in interferometric sensors, as it can provide an output signal that is immune to interferometric drift. With the advent of cost-effective, high-speed real-time signal-processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In synthetic heterodyne, to obtain the actual dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a method is described for determining the former and setting the Bessel function argument to a set value, which ensures maximum sensitivity. Conventional synthetic-heterodyne demodulation requires the use of two in-phase local oscillators; however, the relative phase of these oscillators relative to the interferometric signal is unknown. It is shown that, by using two additional quadrature local oscillators, a demodulated signal can be obtained that is independent of this phase difference. The experimental interferometer is aMichelson configuration using a visible single-mode laser, whose current is sinusoidally modulated at a frequency of 20 kHz. The detected interferometer output is acquired using a 250 kHz analog-to-digital converter and processed in real time. The system is used to measure the displacement sensitivity frequency response and linearity of a piezoelectric mirror shifter over a range of 500 Hz to 10 kHz. The experimental results show good agreement with two data-obtained independent techniques: the signal coincidence and denominated n-commuted Pernick method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multidimensional and one-dimensional quantum-statistical (Bose-Einstein) correlations are measured in proton proton collisions at 0.9, 2.76 and 7 TeV, in proton lead collisions at 5.02 TeV/nucleon pair and peripheral lead lead collisions at 2.76 TeV/nucleon pair center-of-mass energy with the CMS detector at the LHC. The correlation functions are extracted in terms of different components of the relative momentum of the pair, in order to investigate the extension of the emission source in different directions. The results are presented for different intervals of transverse pair momentum, k(T), and charged particle multiplicity of the collision, N-tracks, as well as for their integrated values. Besides inclusive charged particles, charged pions and kaons, identified via their energy loss in the silicon tracker detector, can also be correlated. The extracted source radii increase with increasing multiplicity, and decrease with increasing k(T). The results open the possibility to study scaling and factorization properties of these radii as a function of multiplicity, k(T), colliding system size and center-of-mass energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study was conducted in two different locations in South Brazil, in tillage in the 2009/2010 season on eight sunflower hybrids, aiming to determine the path correlations and coefficients between primary and secondary characters on the main variable of achene productivity. The correlations were similar between environments. The characters of the head diameter and mass of a thousand achenes had a significant influence on sunflower productivity. Based on the magnitude of the direct and indirect effects, we highlighted all primary components on the main variable, beside the good determination coefficient and low residual effect. The secondary component, the number of achenes, despite the significant direct effect on productivity, was indirectly influenced by the primary components, making it an undesirable character for selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal decomposition of pyrrolidinedithiocarbamate and piperidinedithiocarbamate complexes of CoII, NiII, CuII and HgII have been studied by thermogravimetry and differential scanning calorimetry. The decomposition intermediates and final products were identified by their X-ray diffraction patterns. The i.r. spectra are discussed in terms of the thermal decomposition pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time differential measurements of the 133-482 keV γ-γ angular correlation of 181Ta have been performed in solid hafnium complexes of the type [Hf(glycol)4] (glycol = p-chloromandelate, p-bromomandelate, b-naphthylglycolate and mandelate). The quadrupolar frequencies (ωQ) were found to increase within the series. This behaviour was explained by supposing a dissipation of electronic density at the metal level, caused by an increase in intermolecular hydrogen bonding in the complexes throughout the series studied. These results seem to agree with complementary data from IR spectroscopic studies. © 1988.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piezoelectric transducers are widely used in high-resolution positioning systems. This paper reports the experimental analysis of a novel piezoelectric flextensional actuator (PFA), which is designed by using the topology-optimization method through a low-cost homodyne Michelson interferometer. By applying the J(1) - J(4) method for signal demodulation, which provides a linear and direct measurement of dynamic optical phase shift independent of fading, the nanometric displacements of the PFA were determined. Linearity and frequency response of the PFA were evaluated up to 50 kHz. PFA calibration factor and amplification rate were determined for the PFA operating in the quasi-static regime. To confirm the observed frequencies of resonance, an impedance analyzer is also utilized to measure the magnitude and phase of the PFA admittance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peak flow rate data (Qmax) are important for diagnosis of lower urinary tract obstruction. However, the lack of uroflowmetry studies in children, makes their interpretation difficult. With this aim, we studied 167 boys classified in four groups according to their age (G1: n = 48, 6-7 years; G2: n = 43, 8-9 years; G3: n = 37, 10-11 years; G4: n = 39, 12-14 years). We studied in all children, weight, height, body surface area, peak flow rate (Qmax) and the correspondant urinary volume (Vol). Means and standard deviations of Qmax (ml/sec) were: 15 +/- 5 (G1), 15 +/- 5 (G2), 17 +/- 5 (G3) and 22 +/- 7 (G4) respectively. Corresponding urinary volumes (Vol) (mean standard deviation-in ml) were: G1 = 123 +/- 75; G2 = 122 +/- 79; G3 = 158 +/- 96 and G4 = 162 +/- 101. We found a significant correlation (p < 0,01) between Qmax and Vol in groups G2, G3 and G4; and between Qmax and height in groups G1 and G4. The authors demonstrated a positive correlation between maximum flow and voided volume, and an increase of Qmax with age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This clinical study was conducted to correlate the levels of endotoxins and bacterial counts found in primary endodontic infection with the volume of periapical bone destruction determined by cone-beam computed tomography (CBCT) analysis. Moreover, the levels of bacteria and endotoxins were correlated with the development of clinical features. Twenty-four root canals with primary endodontic disease and apical periodontitis were selected. Clinical features such as pain on palpation, pain on percussion, and previous episode of pain were recorded. The volume (cubic millimeters) of periapical bone destruction was determined by CBCT analysis. Endotoxins and bacterial samplings were collected by using sterile/apyrogenic paper points. Endotoxins were quantified by using limulus amebocyte lysate assay (KQCL test), and bacterial count (colony-forming units [CFU]/mL) was determined by using anaerobic culture techniques. Data were analyzed by Pearson correlation and multiple logistic regression (P < .05). Endotoxins and bacteria were detected in 100% of the root canal samples (24 of 24), with median values of 10.92 endotoxin units (EU)/mL (1.75-128 EU/mL) and 7.5 × 10(5) CFU/mL (3.20 × 10(5)-8.16 × 10(6) CFU/mL), respectively. The median volume of bone destruction determined by CBCT analysis was 100 mm(3) (10-450 mm(3)). The multiple regression analysis revealed a positive correlation between higher levels of endotoxins present in root canal infection and larger volume of bone destruction (P < .05). Moreover, higher levels of endotoxins were also correlated with the presence of previous pain (P < .05). Our findings revealed that the levels of endotoxins found in root canal infection are related to the volume of periapical bone destruction determined by CBCT analysis. Moreover, the levels of endotoxin are related to the presence of previous pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of the study was to investigate a possible association between the distance covered in the Hoff test with parameters of maximal oxygen uptake (V_O2MAX), anaerobic threshold, anaerobic fitness, and body composition of professional adult soccer players. Methods Twenty-five professional soccer players (20 ± 3 years) participated in the study. On different days the athletes performed: a graded incremental exercise test in a laboratory to measure V_O2MAX; a specific soccer field test called the Hoff test; a running anaerobic sprint test (RAST); an incremental test on an oval circuit to determine the velocity relative to anaerobic threshold (VAnT) and an estimation of body composition. Results The average V_O2MAX corresponded to 4.1 ± 0.1 L min-1 (54.1 ± 1.2 mL kg-1 min-1 ). The average distance covered during the Hoff test was 1,442.4 ± 30.0 m. The distance covered during the Hoff test showed significant correlations with absolute and expressed in an appropriated scale V_O2MAX (r = 0.44, p = 0.02; r = 0.42, p = 0.02, respectively) while no significant differences were found with body composition, VAnT and RAST variables. Conclusions The present study demonstrated that the distance covered during the Hoff test has weak correlation with V_O2MAX determined in treadmill running, and no correlation with VAnT, body composition and RAST outcomes, probably due to the non-specificity of the proposed tests when associated with the Hoff test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)