213 resultados para anaerobic threshold soccer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power-counting arguments are used to organize the interactions contributing to the NN-->d pi,pn pi reactions near threshold. We estimate the contributions from the three formally leading mechanisms: the Weinberg-Tomozawa (WT) term, the impulse term, and the Delta-excitation mechanism. Subleading but potentially large mechanisms, including S-wave pion rescattering, the Galilean correction to the WT term, and short-ranged contributions are also examined. The WT term is shown to be numerically the largest, and the other contributions are found to approximately cancel. Similarly to the reaction pp-->pp pi(0), the computed cross sections are considerably smaller than the data. We discuss possible origins of this discrepancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 10(5) and 10(9) MPN (100 mL)(-1), while helminth eggs ranged from 0.86 to 9.27 eggs g(-1) TS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antibiotics sulfamethoxazole (SMTX) and ciprofloxacin (CIP) are commonly used in human and veterinary medicine, which explains their occurrence in wastewater. Anaerobic reactors are low-cost, simple and suitable technology to wastewater treatment, but there is a lack of studies related to the removal efficiency of antibiotics. To overcome this knowledge gap, the objective of this study was to evaluate the removal kinetics of SMTX and CIP using a horizontal-flow anaerobic immobilized biomass reactor. Two different concentrations were evaluated, for SMTX 20 and 40 μg L(-1); for CIP 2.0 and 5.0 μg L(-1). The affluent and effluent analysis was carried out in liquid chromatography/tandem mass spectrometry (LC-MS/MS) with the sample preparation procedure using an off-line solid-phase extraction. This method was developed, validated and successfully applied for monitoring the affluent and effluent samples. The removal efficiency found for both antibiotics at the two concentrations studied was 97%. Chemical oxygen demand (COD) exhibited kinetic constants that were different from that observed for the antibiotics, indicating the absence of co-metabolism. Also, though the antibiotic concentration was increased, there was no inhibitory effect in the removal of COD and antibiotics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim is to evaluate the influence of oral contraceptive intake and menstrual cycle on the electrical activity and pressure pain threshold from anterior temporal and masseter muscles. Twenty-eight women on reproductive age were selected, 13 OC users and 15 nonusers. They were weekly submitted to electromyography and algometry of the anterior temporal and masseter muscles during three consecutive menstrual cycles. Electrical activities at rest position and PPTs of temporal and masseter muscles were not affected by menstrual cycle or by OCs uses. Comparison between groups demonstrated that working side electrical activity was increased in OC users in both muscles, except during lutheal phase for the anterior temporal. However, comparison within weeks did not demonstrate statistical difference. It was suggested that, in healthy women, oral contraceptive use may influence electrical activity, but different phases of the cycle may not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine changes on anaerobic power after competitive period in professional soccer players. Twenty five male was evaluated before (PRE) and after (POS) competitive period. To assess anaerobic power was used running based on anaerobic sprint test (RAST), which were determined the maximum power (MAXP), medium power (MEDP), minimum power (MINP) and fatigue index (FI). The test was performed in the first (PRE) and the last (POS) training session of competitive period, wich lasted 20 weeks. There were no significant difference (p>0,05) in POS condition compared to PRE condition on MAXP (10,70 ± 0,95 vs 10,83 ± 0,87), MINP (8,48 ± 0,92 vs 8,28 ± 0,76), MEDP (9,52 ± 0,83 vs 9,41 ± 0,61) and FI (22,73 ± 7,48 vs 25,53 ± 8,79). There was no significant change on anaerobic power after a competitive period wich lasted 20 weeks in professional soccer players.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the speed and the agility between Brazilian soccer players and non-players, regarding maturity status in adolescents 11-15 years old. Forty and two soccer players (age – 159.30±17.28 months old; weight – 48.45±9.96 kg; height – 1.53±0.10 m) and 45 non-players (age – 162.62±24.92 months old; weight – 48.30±8.35 kg; height – 1.54±0.12 m) participated of this study. Participants were classified by maturity status. On 2 different days with 1 week of differences between the assessments the participants were evaluated the agility, by Shuttle Run test, and the speed, by 30 m maximum speed test. The results showed that the maturity status was an influential factor in the performance with better results for individuals in a more advanced stage. The soccer practice does not seem to interfere in the performance of the physical capacity components analyzed, only effective when different maturity levels are involved in the analysis. It is also possible that late maturing boys selectively drop-out of soccer as age and sport specialization increase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is little information on Caribbean soccer players. Thus, the aim this study was to descriptive and to compare the anthropometric, motor and aerobic fitness profile between Trinidad and Tobago team professional and junior soccer players. Twenty six soccer players were evaluated (14 professional and 12 junior): anthropometric (height, body mass, BMI, body fat percent), flexibility (sit and reach), velocity (30 m), explosive strength (horizontal and vertical jump), anaerobic power (maximum, mean and minimum power, index of fatigue) and maximum aerobic power. Student Test-t to independent sample was used in statistical analyzes, considering 5% of significance (p<0,05). Results of professional and junior players were, respectively: height (180,6 ± 8,1; 175,0 ± 6,9 cm), body mass (77,1 ± 7,5; 70,6 ± 8,7 kg); BMI (23,6 ± 1,5 / 23,0 ± 1,6 kgm 2 ); body fat (11,9 ± 1,7; 11,6 ± 1,2 %); sitting and reaching (24,9 ± 10,3; 24,9 ± 7,7 cm); velocity (30 m) (4,61 ± 0,14; 4,66 ± 0,15 s); horizontal jump (263,4 ± 14,9; 239,7 ± 12,1 cm); vertical jump (58,7 ± 4,3; 54,6 ± 6,6 cm); maximum power (7,9 ± 0,9; 6,6 ± 0,8 w∙kg-1 ); mean power (6,5 ± 0,7; 5,4 ± 0,9 w∙kg-1 ); minimum power (5,3 ± 0,7; 4,3 ± 1,1 w∙kg-1 ); index of fatigue (33,0 ± 7,9; 34,8 ± 12,8 %); aerobic power (55,0 ± 3,2; 57,2 ± 4,8 ml∙kg-1 ∙min-1 ). Professional players presented higher horizontal jump and maximum, mean and minimum anaerobic power in comparing to the junior players. The highest values of power tests for the lower limbs may be relationship to the longer time of practice in the modality of professional players, which can also indicate a higher level of specialization, which gives priority to the training of power (force and velocity).