559 resultados para Soldagem por Resistência Elétrica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 1988 to 1992, a study about susceptibility to antimicrobial drugs of bacterias isolated from hospitalized patients was performed. The compared susceptibility to important drugs (ampicilin, cephalothin, cefoxitin, ceftazidime, ceftriaxone, aztreonam, gentamicin, amikacin, peftoxacin, ciprofloxacin, imipenem, oxacillin and vancomicin) was investigated in 1200 strains (300 of each specie) of the prevalent bacterias: E. coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and S. aureus. Minimal inhibitory concentration (MIC) was determined by agar dilution method, using from 0,05 to 256 mcg of each drug per ml of culture medium (Mueller-Hinton). Ranges of MIC, MIC 50%, MIC 90% and the proportion of resistant strains were determined and permited to know the 4 drugs that were found to be more active against bacterias; the CIM 90% values are: E. coli - aztreonam (0,1 mcg/ml), pefloxacin (0,1), ceftazidime (0,25) and ceftriaxone (0,05); K. pneumoniae - aztreonam (0,25), ceftriaxone (0,25), ceftazidime (0,5) and pefloxacin (2,0); P. aeruginosa - imipenem (4,0), aztreonam (16), ceftazidime (16) and ciprofloxacin (16); S. aureus - vancomicina (1,0), ciprofloxacin (8,0), arnicacina (128) and cephalothin (128 mg/ml). The better in vitro antibacterial activity observed was related to: aztreonam (77-100% of the sensitive strains), ceftazidime (50-99,7%), pefloxacin (73-99,7%), ciprofloxacin(80%), imipenem (93%) and vancomicin (100%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cotton genotypes resistance to Alabama argillacea (Huebner, 1818) due to antibiosis has been evaluated in laboratory trials (at 27 ± 2°C, 70 ± 10% relative humidity and 14 hours photoperiod). Six different genetic materials (T 1122-13-1, STO 285 N, JPM 157, T 953-13-4-2, CNPA 9211-21, and CNPA 9211-31) have been tested in a completely randomized experimental design, with ten replications, each one with ten larvae/genotype. Larvae have been supplied with leaves daily. The following variables have been scored: time length of several insect stages (from larvae to adult), average mass of larvae and pupae as well as average larval, pre-pupal and pupal mortality rates. All genotypes have revealed longer overall average time length of stage duration from larvae to adult, as compared to STO 285 N; however, CNPA 9211-31 and CNPA 9211-21 have shown the smallest average mass of pupae along with high frequencies of pre-pupae and larvae to adult mortalities. The results strongly suggest that antibiosis is one of the resistance mechanisms to A. argillacea in that two cotton genotypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the Benders decomposition technique and Branch and Bound algorithm used in the reactive power planning in electric energy systems. The Benders decomposition separates the planning problem into two subproblems: an investment subproblem (master) and the operation subproblem (slave), which are solved alternately. The operation subproblem is solved using a successive linear programming (SLP) algorithm while the investment subproblem, which is an integer linear programming (ILP) problem with discrete variables, is resolved using a Branch and Bound algorithm especially developed to resolve this type of problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A site investigation program was carried out to detect salt-water intrusions in a shallow sedimentary aquifer based on electrical resistivity measurements. The site is located close to Paranaguá harbor, in the Paraná State, Brasil. At this site, high chloride concentration contaminated shallow water wells used to supply water for local industries. The site investigation program included a fieldwork, dipole-dipole electrical profiling, resistivity piezocone tests, physical-chemical analysis of sampled water and interpretation of borehole logs. The resistivity piezocone tests provided two simultaneous information; the soil stratigraphy at a very detailed level and a quasi-continuous resistivity profile. Both information adequately complemented dipole-dipole electrical profiling test data. The integration of all test data allowed identifying the contaminated areas as well as guided the location of new water wells to be installed in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quite common problem in the recovery of degraded areas in the mineral exploration understands the compaction of the soil due to the intense traffic of machines and earth movement. The most common problem of the compaction of a degraded surface is: increase of the mechanical resistance to the penetration of the rooats, reduction of the aeration, alteration of the water flow and heat. Thus the present work had the basic objective of diagnosing the compaction of a degraded area by mining in a space way, through the mechanical resistance the way penetration to guide a future subsoiling in the place seeking recovery. Through the studies it was concluded that the kriging method in agreement with the space variation allows the division of the area studies in sub areas facilitating a future work to reduce cost and unnecessary interference to the atmosphere. The method was shown quite appropriate and it can be used in diagnosis of the compaction in a degraded area by mining, foreseeing subsoiling need.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three pig genetics lineages A, B and C marketed in Brazil, were stunning with the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 - 1.5 A) and the collective gaseous system (COMBI-BUTINA 90% CO 2). The electric stunning provided higher blood splashed levels in the areas of the inside round (0.477 and 0.26, p ≤ 0.01), shoulder/cranial (0.154 and 0.039, p ≤ 0.005), shoulder/central (0.261 e 0.052, p ≤ 0.001), shoulder/caudal (0.180 and 0.030, p ≤ 0.01), loin/central (0.185 and 0.065, p ≤ 0.01), loin/caudal (0.06 and 0.207, p ≤ 0.01) and loin/lateral external (0.061 and 0.013, p ≤ 0.05), as well as more diffuse blood splashed in the areas of the inside round (0.461 and 0.279, p ≤ 0.05), shoulder/cranial (0.154 and 0.039, p ≤ 0.001), shoulder/central (0.231 and 0.039, p ≤ 0.001) and shoulder/caudal (0.185 and 0.026, p ≤ 0.001). The electric stunning also provided higher skin damage levels in the areas of the shoulder (1.098 and 0.795, p ≤ 0.001), body (1.04 and 0.948, p ≤ 0.05) and ham (0.84 and 0.68, p ≤ 0.001), as well as higher eyelid reflex levels (11.57%) comparatively to the gaseous system (2.86%) of a total of 426 pigs. Small indexes of bone fractures and muscle bruises were found in both systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pigs of three genetics lineages A, B and C marketed in Brazil, with alive weight from 100 to 120 kg were submitted to the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 -1.5 A) and to the collective gaseous system (COMBI-BUTINA 90% CO 2). Blood samples, for levels determination of creatine phosphokinase (CPK), lactate and cortisol, as well as samples of the semimembranosus muscle (10 g) for the determination of the gene halothane, were collected. Being compared the electric and gaseous stunning systems, the electric stunning did demonstrate to be more stressful providing larger plasmatic concentrations of cortisol (p ≤ 0.001) and lactate (p ≤ 0.001) for the genetic lineages A and C, in the studied conditions. However it didn't observe significant differences beween the sanguine indicators and stunning systems in subject when the lineage B was considered. Significant differences among the genetic lineages A, B and C were obtained being compared the plasmatic values of creatine phosphokinase (p ≤ 0.001), lactate (p ≤ 0.001) and cortisol (p ≤ 0.001) when stunned with the gaseous system, however when the electric system was used only the cortisol values presented significant differences (p ≤ 0.001). The presence of the gene halothane (Nn) was only observed in the lineage B.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Research and Teaching Farm of the State University of São Paulo (UNESP) - Campus of Ilha Solteira, located in Selviria, in Mato Grosso do Sul State, a study was conducted with the objective of investigating the resistance to penetration of a highly degraded soil due to construction of a Hydroelectric Power Plant. The experimental design was a completely randomized, with five treatments and five replications. The treatments were constituted of the following uses and managements: area in advanced state of degradation; area under regeneration cultivated 13 years with Pinus; area under regeneration cultivated 11 years with green manure and pasture; degraded area with natural regeneration; and area with natural vegetation (savanna). The system where the area was under regeneration with Pinus cultivation and the niches with natural regeneration were the closest to natural condition (savanna). Except for the natural area (savanna), all others presented a higher resistance to penetration in the layer of 0.20-0.40 m, which represents serious limitations for growth of plant roots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The soil mechanical resistance to penetration (PR) has great influence on vegetative development as the root growth and the crop productivity change in inverse proportion. Thus, the objective of this research was to study correlation between the bean grain productivity and the PR in an Oxisol cultivated for four years in no-tillage system at FEIS/UNESP. The attributes PR and yield were determined in a regular grid with 119 sample points. The PR was determined in the layers of 0-0.05, 0.05-0.10, 0.10-0.15, 0.15-0.20 and 0.25-0.30 m. The results were submitted to procedures of descriptive statistics, linear correlation and geostatistic analysis. The linear correlation between the yield and PR was practically null, as in all soil layers investigated it showed determination coefficients (R2) smaller than 0.03 and not significant. The geostatistic analysis showed moderate structure of spatial dependency for PR in the layers of 0.05-0.10 and 0.10-0.15 m, and strong for yield; however, the conjugate spatial analysis of such attributes showed no correlation, therefore, the spatial variability of PR did not influence the yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of salt concentration levels in electrical conductivity (EC) were evaluated in chrysanthemum root, cultivated in substrate using two sampling methods, under greenhouse conditions. The experiment was carried out in Paranapanema, São Paulo using the experimental design in randomized blocks and four replications. The treatments consisted of eight sampling periods of substrate solutions in pots: 7, 14, 21, 28, 35, 42, 49 and 56 days after strike root and five salt concentration levels of applied saline solution: 1.42; 1.65; 1.89; 2.13 and 2.36 dS m -1 in the vegetative period and during the reproduction period of flower budding: 1.71; 1.97; 2.28; 2.57 and 2.85 dS m -1. The substrate solution EC monitoring was done using two methods: solution extractors and 1:2 water diluted solution. The use of solution extractors and 1:2 water diluted solution allowed substrate solution EC monitoring along the culture cycle; the amount of salt concentration applied in the substrate caused the substrate salinity increase; the method using solution extractors presented higher EC values in the substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil management measures that increase the efficiency of organic matter cycling and maintain favorable soil structure are needed for improving soil quality. On the other hand, soil structure degradation due to inadequate soil management systems is widespread. Among the indicators of soil physical quality, saturated hydraulic conductivity and penetration resistance are thought to be sensitive to soil management system. The aim of this work was to study the influence of soil tillage system and organic fertilization on selected soil physical properties after the first year of treatment. The field work was conducted in Selviria, MS, Brazil on an Oxisol. The experimental design was randomized complete blocks with split-plots, with 12 treatments and 4 repetitions. Tillage treatments included conventional ploughing (CT) and direct drilling (DD). Fertilizer treatments were: 1) manure, 2) manure plus mineral, 3) traditional mineral 4) plant residues of Crotalaria juncea, 5) plant residues of Pennisetum americanum and 6) control plot. The plots were cropped to bean in winter and to cotton in summer, and both cultures were irrigated. After one year no significant differences between treatments in mechanical resistance and porosity were found. However, saturated hydraulic conductivity and infiltration were higher in the conventional tillage treatment at the 0.00-0.10 m depth. Moreover, an improvement in soil physical condition by organic fertilizers was shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research studies the influence of the pozzolanic activity of the calcareous and basalt in the resistence behavior of the compressive strength of high performance self-compacting concrete (HPSCC). The selected aditives are the calcareous filler and basalt filler, for they are industrial residues helping that way the sustainable development. The paste of this concrete type is constituted of cement, silica fume, calcareous filler or basalt filler, water and superplasticizer additive. In this research the relationships water/cement are fixed in 0,40 kg/kg, silica fume/cement of 0,10 kg/kg and the relationships filler/cement and superplasticizer/cement are determined through of Marsh́s cone and mini-slump tests. The granular skeleton is gotten from a composition between quartzous sand and brita of basalt that presents the lesser index of emptinesses. The results show that the HPSCC with the addition of calcareous filler has greater compressive strength than what the HPSCC with addition of basalt filler in the ages of 7, 28 and 63 days. It is explained by the fact that the calcareous filler presents greater index of pozzolanic activity than the basalt filler. Besides that the relation water/fine for the HPSCC with calcareous filler is 0,27 l/kg whereas the HPSCC with basalt filler is of 0,29 l/kg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical electrical soundings using eletroresistivity method were carried out in the public waste landfill in Macapá - AP, having as a goal to investigate the geoelectrical and hidrogeologic characteristics of the ground. The results of geophysics interpretation allowed obtaining a model of five geoelectrical layers until the depth of 14,6 m. This model is correlated to a sedimentary sequence of clay-silt-sandy with laterite. The main flow of the water table, also determined, is concordant to the topographical gradient.