347 resultados para Implantes de Medicamento


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: a ausência ou alterações da estrutura dentária, principalmente em áreas estéticas, compromete a aparência, as relações sociais, a autoestima e, consequentemente, a qualidade de vida do indivíduo. Atualmente, avanços tecnológicos e científicos na Odontologia têm possibilitado várias opções de tratamentos reabilitadores e restauradores que oferecem resultados cada vez mais seguros e confiáveis. Objetivo: relatar, por meio de um caso clínico, a recuperação da harmonia dos dentes anteriores com a utilização de laminados de cerâmica e prótese sobre implante associada a recursos para recuperar a estética gengival. Conclusão: o planejamento adequado, associado aos conhecimentos de uma Odontologia integrada, possibilita resultados extremamente satisfatórios, resgatando a função e a estética, tanto dentária quanto gengival, proporcionando um sorriso harmonioso e o bem-estar social do paciente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery. Methods: Thirty Wistar white rats received subcutaneous implants ande the revestiment of silicone gel Silimed, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11 mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Results: Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Conclusion: In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A remodelação óssea é um processo contínuo, que possibilita a substituição de osso envelhecido e danificado por tecido novo. A reparação ao redor de implantes osseointegráveis e enxertos ósseos em situações desfavoráveis depende do estabelecimento de um adequado contato entre tecido ósseo e implante por meio da estabilidade primária. Tendo em vista a importância da estabilidade primária do implante na biomecânica e conseqüente osseointegração, a associação de biomateriais reabsorvíveis ao sítio de instalação dos implantes se torna relevante. Destes biomateriais, destaca-se o copolímero de ácido polilático/ poliglicólico (PLA/PGA), que poderia contribuir com a estabilidade temporária dos implantes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report shows how the prognosis of severe mandibular atrophy can be improved with the use of short dental implants. A Caucasian 54 years-old male patient received four dental implants in the anterior mandibular region. Four months later, the definitive prosthesis was delivered. At the 8-year follow-up period, no complaints or loss of integration were reported. Short dental implants with complete, fixed definitive prosthesis can be a successful treatment in the mandibular arch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the search for treatments faster and aesthetic improvement of materials and surgical techniques, immediate implants have become a clinical reality increasingly practiced. Thus, based on literature the specific purpose of this study was to address critically the concepts of immediate implants, discussing issues related to dental extraction, milling technique, care of the periodontal tissues support and protection, prosthetic replacement, benefits, indications and contraindications. To this end, from Pubmed electronic crawler Medline, 54 articles published between 1990 and 2009, over 4 items classics, all in English were selected. The Studies have shown success rates for this technique Conventional techniques like two-stage surgery, many different techniques and planning are present among these techniques, and implants more immediate subject to failures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: to evaluate implant survival immediately placed after tooth extraction considering different sites, prosthodontic modalities, and the need for biomaterials. Material and methods: dental records of 500 patients treated with dental implants between 2004 and 2011 were screened. Results: only 200 records (20%) corresponded to immediate implants. Reasons for tooth extraction included extensive caries, bone loss, and root fractures. From the 197 immediate dental implants, 86 were placed in the maxilla with a survival rate of 93.9% and 111 in the mandible (survival rate of 99.1%). The overall survival rate was 97.46%. Prosthodontic modalities identified were: Brånemark classic complete denture screwed prostheses (36%), overdentures (5.6%), fixed partial denture (31%), and single-tooth prostheses (27.4%). Also, it was observed that in 33% of cases there was a need for the use of grafts and/or biomaterials. Conclusion: it can be concluded that, when correctly indicated, immediate implants are an excellent choice. The anterior mandibular region, screwed and overdenture-type prostheses presented higher success rates when associated to immediate implant placement. The need for bone graft/biomaterial does not affect the clinical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maxillary sinus lifting surgery is considered an excellent option for patient rehabilitation in cases of maxillary sinus pneumatization. This longitudinal study was performed in 41 patients to evaluate 51 maxillary sinus lifting procedures concomitant to autogenous bone grafted from mandibular ramus. Of the 107 implants installed, 28 were immediate fixations. Success index achieved regarding to bone graft was of 98.04%. The implants installed immediately or after bone grafting resulted in success rates of 92.86% and 94.59% respectively, with no statistically significant differences between them. Surgeries for bone grafting and immediate installation are considered a reliable treatment alternative provided that both anatomical structures and tissue physiology are kept in good conditions, with appropriate indication and techniques for good implant stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface treatments have been used to modify the surface of titanium alloys. The purpose of this study is to evaluate the surface of Ti-30Ta alloy after biomimetic approach associated to antibiotic incorporation. The ingots were obtained in arc melting furnace, treated and cold-worked by swaging. The surface treatment was performed in two steps: biomimetic treatment and antibiotic incorporation. For biomimetic treatment, first an alkaline treatment (NaOH 1M at 60ºC) was performed, followed by heat treatment and immersion in SBFx5 (Simulated Body Fluid) for a period of 24 hours. In order to incorporate the antibiotic, samples were immersed in a solution formed by drugs plus SBFx5 for 48 hours. The sample surfaces were analyzed by scanning electron microscopy (SEM), X-Ray diffraction (XRD), atomic force microscopy (AFM) and contact angle measurements. The release of antibiotic from coated implants was measured in phosphate buffer saline at pH 7.4 by using UV/VIS spectrometry. Results have shown changes on the surface after incorporating the drug, which is gradually co-precipitated with the Ca-P crystals, forming a uniform and rough layer on the metal surface

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi o de estudar a resistência à corrosão em placas de aço inoxidável 316L, com diferentes tipos de acabamento e tratamento superficial, e a possível interferência dessa reação corrosiva na consolidação óssea. Utilizaram-se placas semi-acabadas, polidas, tratadas com jatos de microesferas de vidro e passivadas, as quais foram aplicadas na epífise distal do rádio de cães. Foram utilizados 12 animais, divididos em dois grupos, nos quais, após osteotomia bilateral do rádio e ulna, foram realizadas osteossínteses do rádio, totalizando 24 procedimentos. Avaliou-se a evolução clínica e radiográfica das regiões que receberam os implantes aos 30, 60, 90, 180, 240 e 360 dias. Os animais do grupo 1 (GI) foram sacrificados aos 180 dias e os do GII aos 360 dias para estudo histológico e de microscopia eletrônica de varredura do local da osteotomia sob a região dos implantes metálicos e para estudo da resistência à corrosão no organismo, pelos implantes metálicos, por meio de análises química e metalográfica (microscopia óptica e eletrônica de varredura e espectroscopia de espalhamento de energia por raios X). Os animais recuperaram a função dos membros operados 24 horas após a cirurgia. Radiograficamente, verificou-se a consolidação óssea em todos os animais. Macro e microscopicamente não foram observados sinais de corrosão nos implantes metálicos, exceto em uma placa passivada, aplicada no rádio esquerdo de um animal, na qual a corrosão foi detectada pela microscopia óptica e eletrônica de varredura. Este estudo permite concluir que as placas de aço inoxidável 316L, independente do acabamento superficial a que foram submetidas, não sofreram corrosão ou reações adversas e foram efetivas no tratamento das fraturas experimentais do rádio e ulna de cães.