455 resultados para Electric Power Transmission
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Hybrid system micro-generation integration of PV-wind power is presented by a form of energy in which problems resulting from variability in the intensity of wind and solar intensity are possible mitigation either by complementation between one source to another or the largest stability configured by the generate the system. Based on this context, this work aims to assessing the performance of a hybrid system PV-wind power energy small of a rural property for their electrification. The study has been developed at the Rural Laboratory Powering from Engineering Department of UNESP. In order to present this research, a hybrid system has been installed PV-wind power, composed of one 400Wp windmill and a 300 Wp PV-system. The results obtained allowed us to evaluate the solar and wind energy supplied ranked among 285 and 360 kWh electric power generated by the PV-wind power hybrid system stood between 25,5 and 31 kWh. At is to say achieving yield of approximately than 10% during one year observation period, i.e., it was concluded that the performance of the hybrid system depended essentially the energy received and generated by the PV-system and that there was complementation between generating wind power and PV-systems with regard to time of day and the annual seasons by confirming the technical feasibility of this kind system of micro-generation in small rural properties.
Resumo:
This paper presents a mixed-integer convex-optimization-based approach for optimum investment reactive power sources in transmission systems. Unlike some convex-optimization techniques for the reactive power planning solution, in the proposed approach the taps settings of under-load tap-changing of transformers are modeled as a mixed-integer linear set equations. Are also considered the continuous and discrete variables for the existing and new capacitive and reactive power sources. The problem is solved for three significant demand scenarios (low demand, average demand and peak demand). Numerical results are presented for the CIGRE-32 electric power system.
Resumo:
The theory presented in this paper was primarily developed to give a physical interpretation for the instantaneous power flow on a three-phase induction machine, without a neutral conductor, on any operational state and may be extended to any three-phase load. It is a vectorial interpretation of the instantaneous reactive power theory presented by Akagi et al. Which, believe the authors, isn't enough developed and its physical meaning not yet completely understood. This vectorial interpretation is based on the instantaneous complex power concept defined by Torrens for single-phase, ac, steady-state circuits, and leads to a better understanding of the power phenomenon, particularly of the distortion power. This concept has been extended by the authors to three-phase systems, through the utilization of the instantaneous space vectors. The results of measurements of instantaneous complex power on a self-excited induction generator's terminals, during an over-load application transient, are presented for illustration. The compensation of reactive power proposed by Akagi is discussed and a new horizon for the theory application is opened.
Resumo:
This paper presents a novel single-phase high power factor PWM boost rectifier, featuring soft commutation of the active switches at zero-current (ZCS). It incorporates the most desirable properties of the conventional PWM and the soft-switching resonant techniques. The input current shaping is achieved with average current mode control, and continuous inductor current mode. This new PWM converter provides ZCS turn-on and turn-off of the active switches, and it is suitable for high power applications employing IGBTs. Principle of operation, theoretical analysis, a design example, and experimental results from a laboratory prototype rated at 1600 W with 400 Vdc output voltage are presented. The measured efficiency and power factor were 96.2% and 0.99 respectively, with an input current THD equal to 3.94%, for an input voltage THD equal to 3.8%, at rated load.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O presente trabalho teve por objetivo avaliar a quantidade de calda de pulverização depositada nas folhas de Brachiaria plantaginea, em aplicações de pós-emergência precoce, em que se variou o volume de calda de pulverização, a densidade de plantas m-2 e o ângulo de posicionamento da ponta de pulverização na barra de aplicação. Para isso, foram conduzidos três experimentos em condições de laboratório. Nestes estudos, o volume de calda de pulverização foi obtido por meio da variação da velocidade de deslocamento de um veículo composto por plataforma e quatro rolamentos tracionados por um motor elétrico. Foi utilizada a ponta de pulverização XR Teejet 8001 EVS, na pressão de 241,4 kPa. O delineamento experimental utilizado foi o inteiramente casualizado, com cinco repetições. No primeiro experimento, os volumes utilizados foram de 1147,57; 860,68; 573,78; 459,02; 344,27; 229,51; 114,75; e 57,37 L ha-1 de calda de pulverização, com densidade de 600 plantas m-2. No segundo experimento foram estudadas as densidades de 300, 600, 900 e 1.200 plantas m-2; neste caso, utilizou-se o volume de 229,51 L ha-1 de calda de pulverização. No terceiro experimento avaliou-se o posicionamento do ângulo da ponta de pulverização na barra de aplicação e utilizou-se a densidade de 600 plantas m-2. Estudaram-se os ângulos de -30º, -15º, 90º, +15º e +30º e os volumes de calda de pulverização de 198,76; 221,69; 229,51; 221,69; e 198,76 L ha-1, respectivamente. Foram adotados sinais negativos para o sentido de deslocamento do veículo e sinais positivos para o sentido contrário ao deslocamento. As avaliações do depósito de calda de pulverização, na planta e no solo, foram feitas utilizando-se condutividade elétrica. A porcentagem de depósito de calda de pulverização nas plantas de B. plantaginea foi incrementada com a redução do volume de calda pulverizada por hectare. O depósito de calda por planta foi maior nas densidades maiores de plantas. O ângulo de posicionamento da ponta de pulverização na barra de aplicação incrementou o depósito de calda nas plantas de B. plantaginea, quando comparado com o ângulo de 90º.