235 resultados para EQUAÇÕES DIFERENCIAIS PARCIAIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Matemática em Rede Nacional - IBILCE
Resumo:
Pós-graduação em Física - IFT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Um bloco de poliuretano recebeu três implantes de hexagono externo, no posicionamento compensado. Para cada implante foi conectado o pilar protético microunit. Foram realizados cinco enceramentos com três coifas plásticas cada um, que foram fundidos em monobloco numa liga de cobalto-cromo. Foram colados quatro extensomêtros tangenciando cada implante, sendo dois extensomêtros para o implante central. Após o acabamento, as estruturas foram fixadas nos respectivos locais com o parafuso de retenção com torque de 10 Ncm, obtidos com um torquímetro. Para aplicação de carga sobre os corpos-de-prova foram selecionados cinco pontos de aplicação de carga. O dispositivo de aplicação de carga–DAC foi utilizado 30 kg de cargas verticais estáticas, empregando uma ponta esférica de 2 mm de diamêtro, durante 10 segundos em cada um dos pontos estabelecidos, sendo, neste instante registradas as micro deformações de cada extensômetro. Foi utilizado o teste de análise de variância T Student e o nível de significância foi o valor convencional de 5%. Para cada implante foi analisada a microdeformação ocorrida. Os resultados obtidos mostraram que houve uma diferença estatisticamente significativa entre os pontos não-axiais D e E (t = 5,21 df = 4, p = 0,006 < 0,05) e não foi estatisticamente significativa para os dados axial entre os pontos B e C (t = 6, 57, df = 4, p = 0,003 < 0,05 / 3). Conclui-se que,a aplicação de carga ao redor de três implantes de hexágono externo no posicionamento compensado,mostra que os pontos não-axiais sofrem maior micro deformação do que os pontos axiais
Resumo:
This paper presents a study of the applicability of adsorption isotherms, known as Langmuir and Freundlich isotherm, between the biosorptive interaction of yeast lyophilized Saccharomyces cerevisiae and textile dyes. To that end, we prepared stock solutions of the textile dyes Direct Red 23 and Direct Red 75 in the concentration of 1.000μg/mL and a yeast suspension at 2,5%. We did experiments for two cases, firstly for the case that we have a fix concentration of yeast at 0,500mg/mL and an variable concentration of dye range from40, 50, 60, 80 and 100μg/mL, then for the case that we fixed the concentration of dye at 100μg/mL and the yeast concentration was variable range from 0,250, 0,500, 0,750, 1,000, 1,250mg/mL. For the dye Direct Red 23 we did analysis in the pH 2,5, 4,5 and 6,5; for the Direct Red 75, we just did for the pH 2,5. We leave the dye solution in contact with the yeast for 2 hours at a constant temperature of 30°C and then centrifuged and analyzed the sample in a spectrophotometer and finally made and analysis of parameters for the removal and study of the isotherms. After the biosorption, was observed that for the Direct Red 23 in the pH 2,5 was needed 1,407mg/mL of yeast for total removal, while for the pH 4,5 was needed 8,806mg/mL and in pH 6,5 was 9,286mg/mL; for the Direct Red 75 in pH 2,5 was needed 1,337mg/mL. This difference can be explain by the adsorption isotherms, was observed that in the case when the yeast was fix when we had in a acid pH the behavior of the system was compatible with the Langmuir isotherm, and thus, an monolayer pattern. And that when we decrease the acidity of the medium the system became more compatible with a Freundlich isotherm, and thus, a multilayer pattern; for the case that the yeast was variable this is not much evident, however for the pH 2,5 she became compatible with a Langmuir isotherm... (Complete abstract click electronic access below)
Resumo:
In this work concepts of flammability limits of anhydrous and hydrated ethanol to pressures below atmospheric, using the Dalton model for gaseous mixtures. Theoretical and experimental methods for determining the boundaries and the influence of parameters such as concentration, temperature and pressure were introduced. Analyzes from partial pressures of fuel vapor and correlations with temperature and total pressure were made. Finally presents an overview of aviation fuels, their requisites and trends in the use of biofuels in commercial aviation industry
Resumo:
In this work, it is presented a novel method for calculating some intrinsic parameters such as capture mean time, thermic emission mean time, capture probability and noise gain on quantum well infrared photodetectors. Such devices are built by depositing layers of semiconductors of different energy gap, forming quantum wells. The present method uses rate equations to describe the occupation of discrete states of the quantum wells, that together with noise gain equations given in literature, are solved self consistently. The input data of the method is experimental measurement of dark current (current measured with no relevant incident photon) versus applied bias. In order to validate this approach, the values obtained were compared with results from literature
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)