206 resultados para water treatment plant


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The persistence of MCs in aquatic environments and their difficult removal in the conventional water treatment is a challenge to companies of sanitation. However, the MCs are susceptible to degradation by bacteria present in water, sediment and sewage effluents. In this study, we investigated the biodegradation of MCs by microorganism present in carbon filters with biological activity (BAC) and their phylogenetic identification by sequencing gene 16S RNA. A study of water containing MCs was used, with different compositions, plus a filters BAC effluent. The results showed that of MCs were biodegraded by microorganism present in the biofilm. This study provides the ability to complete biodegradation of MCs by bacteria present in BAC filters and the possible use of these microorganisms as alternative of the removal of MCs in the treatment of drinking water

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The process of environmental impact assessment (EIA), in the extent of previous environmental studies, has as one of its functions to provide subsidies to the actions of environmental managment of enterprises. However, the proper estructuring of programs that allows to support this managment does not often occurs. This research sought as one of its objectives to evaluate in which extent the process of EIA can be a subsidie for the EMS, providing basic elements of this system. In addition, more specifically, the research had as one of its objetives the development of subsidies for the implantation of an Environmental Managment System (EMS), based on the model of ISO 14001 (2004), for a sewage treatment plant yet to be constructed in the city of President Venceslau / SP. In order to achieve theses objetives, a discussion was held based on the evaluation of environmental studies available in the library of Cetesb / SMA. Still, for the elaboration of subsidies for the EMS of the treatment plant, the research was focused on the structuring of environmental management program, based on the information contained in its Preliminary Environmental Report (PER). The research had as one of its products, the development of subsidies for the planning and control of the environmental aspects and impacts and for the environmental program of the enterprise, based on the use of environmental indicators. It was concluded, based on the results that, in general, the previous environmental studies analyzed showed little emphasis on the phase of development of structured environmental programs that offer guidelines to achieve the desired results for the environmental performance of the company.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We conducted a study of the quality of water distributed by Artesian Well in relation to water supply served by the public for purposes of human consumption of UNESP Campus Guaratinguetá. Two sections of the network were randomly chosen and monitored for 105 days: the stretch of the pipeline started off the Water Treatment Station of the Autonomous Service of Water, Sewage and waste in the Municipality of Guaratinguetá and ended in a point consumption of the Child Family Center, while the section B began at the output of an artesian well and finished in a point of consumption of the Department of Civil Engineering. It is the deterioration of water quality in parts A and B, through comparative analysis of Bicarbonates, Total Hardness, Total Iron, free residual chlorine, pH, Total Residual, Turbidity, Conductivity, Color, Fecal Coliforms and Total Coliforms. Among the observations that can be highlighted: the Total Hardness was found in highest concentration in the extract; for Total Iron significant variations were obtained for both parts, and reduction of this parameter in two points of consumption analyzed, not the expected increase concentration, because the contact of water along the pipe, the CRL showed significant depletion to section A, which can be related to impurities in the water, the presence of biofilm on the walls of pipes, or because this is the stretch of greater extent to be covered by water for pH, this indicated that the water is alkaline and slightly acidic stretch in section B; Turbidity was found for the higher concentration to the passage, and a considerable reduction of this parameter at point consumption due to deposition of particulate matter along the stretch, the conductivity also showed a higher concentration in the extract, as well as an increase in this parameter at the point of consumption. Upon leaving ... (Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper aimed to study the treatability of rainwater collected in Rio Claro, SP, using natural coagulant tannin based. The tannin was compared with other too primary coagulants, namely ferric chloride and corn starch. Assays were performed in laboratory scale using equipment known as Jarteste and aimed to study the conditions most suitable dosage and coagulation pH. First tests were conducted to compare the coagulating and determination of the conditions to be used in the following tests, taking as a criterion the greatest efficiency for water treatment. Also performed were performed tests to construct the tannin coagulation diagram, using the optimal concentration found in the previous phase, by varying the dosage of coagulant and the pH of clotting in order to determine the isoefficiency regions for apparent color and turbidity. Finally, tests were performed cyclically filtration with filter paper. Preliminary tests indicated that the vegetable tannin concentration 3% (m/m) from the commercial solution was presented the best set of results (84.3% removal of apparent color and 82.51% removal of turbidity) compared to ferric chloride (66.25% removal efficiency and apparent color of turbidity 67.82%) and starch (73.68% removal efficiency apparent color and turbidity to 67.19%). The coagulation diagrams indicate that the best region to work with vegetable tannin 3% is where the coagulant dosage ranges from 15 mg/L to about 37.5 mg/L and coagulation pH ranging from about 6.5 to 7.5. The cyclic filtration showed to be not efficient for the best dosage of coagulant, due to the process of clogging of the filter paper, but proved to be efficient for other dosages. Thus, for the waters studied, the results indicate that the natural coagulant based tannin is an alternative to conventional coagulants, possessing benefits of technical and environmental

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Educação - FFC

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The progressive growth of the population and the increase of sewage generated has demanded of society and public policies that, besides the collection network deployment is carried out the treatment and proper disposal of treated sewage in all brazilian municipalities. The aim of this study was to monitor and evaluate the work of implementation of a Sewage Treatment Plant (STP) in Guaratinguetá city of São Paulo state, to identify the compliance with legal requirements and the NBR 12,209/2011. The construction of this ETE met all the requirements of NBR 12209/2011 and benefited a large portion of population with the sewage treatment. Based on the results of this assessment it was concluded that the construction of a STP is relatively simple, differing only on the legal requirements related to the location, area for the construction and materials used in the work. The knowledge generated in this study will assist the public policies in the implementation of STPs in municipalities that do not yet have this basic sanitation

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA