185 resultados para laser microwelding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have revisited the assignments of the far-infrared laser lines emitted by (CH3OH)-C-13 by comparing the laser systems to a high resolution Fourier transform absorption spectrum of (CH3OH)-C-13. The absorption spectrum was analyzed by means of the ''Ritz'' program, which calculates the energy level values directly from the Rydberg-Ritz combination principle. We report new assignments for 11 FIR laser transitions, 17 frequency predictions for new possible laser lines, and we confirm 11 previous assignments. (C) 1996 Academic Press, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated the high-resolution Fourier transform spectrum of the C-O stretching fundamental band of CD3OH in order to assign far-infrared (FIR) laser transitions. The absorption spectrum was analyzed by means of the ''Ritz'' program, which calculates the energy level values directly from the Rydberg-Ritz combination principle. We have also used the ''LaseRitz'' program to facilitate the assignment of the FIR laser lines. As a consequence we could determine 12 new assignments, confirming 4 previously proposed ones and predicting new FIR laser emissions. (C) 1997 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study compares wound healing efficiency on a rat's skin when the incision was closed with a conventional suture versus vaporized with a CO2 laser. Materials and Methods: In this study, 24 rats were used, and two longitudinal incisions were made with a conventional scalpel in the dorsum of each rat. The left incision was sutured with nylon thread, and the right incision was closed by vaporization with a defocused CO2 laser in continuous mode with an 8-watt power density. Clinical photographs were taken immediately after the procedure, 24 h later, and after 3, 7, 14, and 21 days, documenting the healing of the incision. Results: the results showed that there was an initial delay in wound repair in the vaporized incision as compared to the scalpel incision, but after 21 days, both incisions showed the same clinical characteristics. However, the vaporized incision showed no trauma of the tissue, as opposed to the sutured incision, and no hemorrhagic complications. Conclusion: These results suggest that the CO2 laser can eventually replace the use of sutures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we analyzed possible damages that vaporization from laser radiation could cause to implant material. Fifteen standard titanium implants, measuring 3.75 mm in diameter by 7 mm in length, were placed into the upper and lower jaws of three dogs according to Branemark's system. After osseointegration, all implants were exposed. In group I (control) conventional exposure with a punch was used; in group II, a CO2 laser with 2 W (power density: 256 W/cm(2); fluency: 0.077 J/cm(2), and a pulse mode of 0.30 ms) was used, and in group III 4 W (power density: 512 W/cm(2), fluency: 0.154 J/cm(2), and a pulse mode of 0.30 ms) was used. After vaporization, the cover screws were removed and sent for metallographic examination. The results showed that cover screws irradiated with 2 and 4 W power caused no superficial or microstructural alteration. The results also showed that the prescribed power densities, fluencies, and the use of the pulse mode were suitable for exposing implants without damage to tissue or implant material. (C) 2002 Laser Institute of America.