195 resultados para eletrocardiografia convencional


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to evaluate the electrocardiography effects (ECG), sedation time and quality of recovery due to buprenorphine (G1) and butorphanol (G2) administration in dogs pretreated with acepromazine. Seven adult dogs were submitted to both protocols, with a thirty days interval between groups. G1 animals were premedicated with acepromazine (0.1 mg/kg) followed 10 minutes later with buprenorphine (0.005 mg/kg), both applied intravenously. The same procedure was performed for G2 employing butorphanol (0.3 mg/kg) instead of buprenorphine. The measurements of the variables heart rate (HR), duration and amplitude of P wave, P-R intervals (PR), QRS complex duration, R wave amplitude, Q-T intervals (QT) and R-R intervals (RR) were taken immediately before application of acepromazine (M0), 10 minute after administration of acepromazine (M10) and 10 minutes after opioids administration (M20). Serial measurements were carried out in 10 minute intervals after the administration of butorphanol or buprenorphine up to 60 minutes. Numeric data were submitted to Tukey Analysis (p < 0.05). The amplitude of P wave decreased 30 minutes after the administration of the butorphanol. Sedation time was longer in G1 (78 minutes) than G2 (72 minutes) and recovery was good in both groups. These results indicate that butorphanol or buprenorphine produced discreet alterations on ECG, which don´t contraindicate its clinical use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of several methods for solving aesthetics in a clinical case can be a complicating factor. The diagnosis and planning of the event held in conjunction with the dental technician expand the possibilities of success. The present case illustrates the aesthetic resolution through the association of implant- and tooth-supported prostheses using metal free ceramic systems. A 38-year old male patient presented with a complex smile. After diagnosis and treatment planning, two ceramic crowns were made, one on tooth 11 and one on the implant region 21, along with a laminated porcelain veneer on the region of 12. Aesthetic needs of the patient are predictable only with a sound diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study, clinical, prospective, randomized study was conducted from August 2004 to February 2008 in a convenience sample of 60 women who underwent breast surgery with axillary dissection, divided into two groups (n = 30). The GI (Guidance Kit with different textures, to perform at home) and GII (control). The objective was to analyze the effect of home orientation in patients after surgery for breast cancer complaining of numbness, evaluation, and the conventional esthesiometer. The surface sensitivity was assessed by monofilament Semmes-Weinstein and evaluation using conventional two test tubes with hot water (38 to 43o C) and cold (16 to 27o C), paintbrush, needle. The GI was subjected to 10 sessions and assessments in both 3 times. The M1 (pre intervention), the M2 (post-intervention) after 10 sessions of physical therapy intervention and M3 (washout) after 3 months the second time for assessment. The region targeted for evaluation and intervention was the sensory nerve dermatome intercostobrachial. In the test of Goodman (conventional assessment) there was improvement in both groups, the P1, during the thermal evaluation. The t-test of student (esthesiometer) there was improvement in P2 only in GI (p = 0.003) between points 1 and 2 while the time 3 (p = 0.121 and p = 0.733 respectively). It was concluded that there were divergent and opposite results after examining the effect of home orientation in the nerve dermatome intercostobrachial, evaluation, and the conventional esthesiometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryopreservation of sperm is important to preserve the germplasm from animals of genetic value, which can die unexpectedly. This study compares conventional and automated methods of cryopreservation of spermatozoa obtained from the epididymis of bulls post-mortem. Twenty-two epididymides were obtained from a commercial slaughterhouse. Spermatozoa were collected from the tail of the epididymis using the retrograde flow technique. Thus, the samples, which were diluted in 10 ml of extender without glycerol (Botubov® I, Botupharma, Botucatu, SP, Brazil), were evaluated on motility, sperm vigor, structural and functional (swelling hypoosmotic test) membrane integrity, mitochondrial activity, sperm viability and ADN fragmentation. The samples were divided into two aliquots and diluted in extender with glycerol (Botubov® II, Botupharma, Botucatu, SP, Brazil) at a concentration of 50x106 motile sperm/0.5 French straws. One sample was frozen by the conventional method (4 hours at 5°C, in a refrigerator and 20 min in nitrogen vapor) and the other by the automated method (Cryogen® Dualflex, Neovet, Uberaba, MG, Brazil). The parameters were higher in all the tests of fresh sperm samples, with the exception of the swelling hypoosmotic test, which showed no significant difference when the results were compared with sperm frozen by the conventional method. The average motility of fresh spermatozoa was 74%, and conventional and automated averages were 29 and 25%, respectively. Therefore, although cryopreservation techniques reduce sperm quality parameters, the viability of the sperm is maintained, and these methods can be used to preserve sperm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to dimension the economic risks and returns on adopters of genetically modified (GM) maize in one of the major corn producing regions of São Paulo state. We performed analysis of variation of the quantities and prices of insecticides used, productivity gains, and variation in the price differentials between GM maize and conventional hybrids seeds, according to account to the maize prices oscillation during the period studied. The net benefits methodology was used, in other words, the economic gains minus the costs of GM technology under risk conditions were calculated. The net benefits was calculated as a function of four critical variables: 1) GM maize productivity; 2) costs of pest control; 3) maize price; 4) GM seeds cost. The probability distribution functions of these critical variables were estimated and included in the net benefit equation. Using the Monte Carlo simulation methodology, the following indicator sets were estimated: central tendency measurements, variability in net benefits (total benefits minus total costs), sensitivity analysis of the net benefits in relation to the critical variables, and finally, a map of the risk to GM technology adopters. These indicators allow one to design economic scenarios associated with their probability of occurring. The results showed probability of 85% to positive gains to the farmers who adopted the transgenic maize seed cultivation. The variable with the greatest impact on the farmers' income was the reduction in productivity loss, that means, as higher is the maize productivity, higher will be the net income. The average gain was US$ 137,41 (R$ 2.45/US$)per hectare with the adoption of transgenic maize seed when compared to conventional maize seed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to compare the planimetric survey data of an area equivalent to a small rural property, through values of longitudes e latitudes obtained by a GPS navigation with a conventional survey data. The value of the area obtained with the navigation receiver showed a small difference when compared with the conventional system. Points located under large vegetal cover had impaired reading of coordinates. The navigation receiver can be used to get measurements inside the property for planning purposes and also for measuring he land perimeter, but not for legal purposes. The Google planimeter result in the same area as the one from the conventional survey data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)