223 resultados para decomposição térmica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The climate is one of the main elements of the natural environment that governs the life of man. Specific conditions of temperature, humidity, light, wind and precipitation have direct influence on physiological conditions that man needs to survive and more than that, besides the influence on human and animal physiology, the climatic elements are also responsible for a significant portion of economic activities such as industry, agriculture, commerce, transportation, and others. Therefore, any change in weather patterns has great impact on daily activities, and even more in urban sites, where the most of population is concentrated nowadays. Based on this discussion and concerned in understand the atmospheric structure, this monograph intends to analyze the pattern of atmospheric and temperature element in seven cities of small and medium size located in the state of São Paulo countryside... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper was prepared a polymorphic from of curcumin a natural bioactive compound widely used in Indian medicine in the treatment of a range of illnesses. The preparation was the polymorphic crystallization process and solvent mixtures of organic solvents in order to change the dielectric constant of the solution to obtain crystals. The crystal of curcumin has been studied and characterized by absorption spectroscopic in the infrared, X-ray diffraction powder method and by thermo analytical techniques: thermogravimetry and differential therma analysis (TG-DTA) and differential scanning calorimetry (DSC). The DSC of the pure compound (MP=180,19ºC) showed some differences compared the compound crystallized (MP=176.63ºC) in a mixture of solvents thus indicating the phenomenon of polymorphism, and TG-DTA curve of the compound crystallized showed that this was not a solvatomorphic. Finnally the techniques of X-ray diffraction technique FTIR and powder showed a structural change in the compound crystallized, profile-based graphics when compared to the pure compound, which proves that the compound crystallized it is a polymorph

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-state compounds of general formula LnL3.nH2O, in wich Ln represents lanthanum, lanthanides and yttrium, L is ketoprofen, and n = 0,5 (Pr, Sm, Tb), 1 (La, Eu, Dy, Ho, Er, Tm, Lu) e 1,5 (Ce, Nd, Gd, Yb, Y) were synthesized. Simultaneous thermogravimetry-differential analysis (TG-DTA), differential scanning calorimetry (DSC), X-ray powder diffractometry, infrared spectroscopy and EDTA complexometry were employed to characterize these compounds. The TG-DTA and DSC curves provided information concerning the thermal behaviour and thermal decomposition of synthesized compounds. The experimental and theoretical infrared spectroscopic data suggested that ketoprofen acts as a bidentate ligand towards trivalent lanthanides and yttrium (III)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to verify and compare the efficiency of heat exchangers used in the thermal systems laboratory at Faculdade de Engenharia do Campus de Guaratinguetá - UNESP. Basically, it has been studied two types of heat exchangers: plate type, operating in parallel flow and counter-flow, shell and tube type and also operating in parallel flow and counter flow. Initially it has been presented the didactic equipment and procedures for use of these heat exchangers in the proposed experiments. With the results obtained from the experiments, comparisons were made in order to define the behavior of the heat exchangers regarding some variables. In the study, one comes to the conclusion that the results from shell and tube type of heat exchanger, used in the thermal systems lab, are superior in all conditions analyzed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazil faces a complex problem in respect to municipal solid waste, having been in recent years an increase of its generation without the country there be adequate for proper disposal thereof. In many states , the percentage of waste destined improperly , ie , in dumps , landfills, send- outs , among others , is greater than that disposed in landfills , which would be the most correct way to be made. It can be argued that this discrepancy is due to the high cost of implementation and operation of the landfill, and the same need large areas with physical characteristics that suit their operations . When there is a provision in properly constructed landfills , municipal solid waste grounded generate gases with high potential energy through biochemical reactions during the anaerobic decomposition of organic material stored . Such gases can be used for power generation within the landfill or other economic means . To estimate the gas generation will be sufficient for such economic compensation , there are mathematical models that make estimating the amount of gas produced . These models calculate the energy capacity and generation , using parameters obtained based on the characteristics of solid waste , climate of the region where they are grounded and grounding time . Such models have been raised and studied so that it was possible to perform simulations that demonstrate the behavior of biogas generation related to the external conditions of the landfill that interfere with biological reactions within. The results show differences between the values obtained , it shows that the preparation of the models found and used in the simulations were allocated amounts for different parameters that determine this difference in the estimate . Therefore, to rule, the models have difficulty understanding this because there is no clarity in the formulation of the equations , and the definition of variables and parameters would require a detailed study to...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypothermia is a common phenomenon in the perioperative period, and it affects 60 to 90% of patients submitted to anesthetic-surgical procedures. In order to minimize its incidence, warming methods are used. Such methods can be passive, such as orthopedic cotton, sheets and blankets, or active, such as warm-air blankets and thermal mattresses. In this scenario, the present study aimed at comparing two warming methods used in the intraoperative period. Patients submitted to abdominal surgery in the specialties of gynecology and gastric surgery from August to September 2010 were included in the study. After randomization, they were divided into two groups: one using a thermal blanket (group I) and one using orthopedic cotton (group II). At last, 9 patients were included. The variables for each question were considered according to occurrence frequency. Comparison between groups was performed by Student’s t test. With the purpose to analyze whether there was an association, the chi-square test or Fisher’s Exact test was used. Whenever it was applicable for multiple comparisons, Tukey’s test was utilized; p values < 0.05 were considered to be statistically significant for analysis. The sample comprised 6 males and 3 females submitted to gynecological and gastric surgeries. Their mean age was 48 years for group I and 46.2 years for group II. A predominance of general anesthesia was observed. The time of permanence in the operating room ranged from 80 to 360 minutes. With regard to warming parenteral solutions, the procedure was performed on 5 patients, and infusion of warm solution into the abdominal cavity was performed on 50% of the sample. Concerning the warming method used, 5 patients used a thermal blanket. In view of the results presented, it was not possible to conclude which warming method should be used due to sample size

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the physical content of the following models: Maxwell, Proca, Self-Dual and Maxwell-Chern-Simons. One method we have used is the decomposition in the so called helicity variables, which can be done in the Lagrangian formalism. It leads to the correct counting of degrees of freedom without choosing a gauge condition. The method separates the propagating modes from the non-propagating ones. The Hamiltonian of the MCS and the AD is calculated. The second method used here is the analysis of the sign of the imaginary part of the residues of the two-point amplitude of the theory, showing that the models analyzed are free of ghosts. We also carry the dimensional reduction of the Maxwell-Chern-Simons and Self-Dual models from D = 2+1 to D = 1 + 1 dimensions. Next, we show that the dimensional reduction of those equivalent models also leads to equivalent models in D=1+1. Even more interesting is the fact, demonstrated here, that those reduced models can also be connected via gauge embedding. So the gauge embedding of the Self-Dual model into the Maxwell-Chern-Simons theory is preserved by the dimensional reduction

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG