209 resultados para Transyugular intrahepatic postosystemic shunt (TIPS)
Resumo:
Study the semi-quantitative and quantitative technique in the diagnosis of catheter-related infections in newborns and to determine oxacillin resistance in Staphylococcus isolated. It was analyzed 353 catheter tips from 273 newborns in the Neonatal Unit of Hospital FMB. To confirm the diagnosis of infection, were analyzed the clinical data of newborns, the presence of at least one positive blood culture and growth of ≥ 1000 CFU/mL on quantitative culture and/or ³15 UFC on semiquantitative culture, with the same microorganism isolation (species and drug sensitivity) in blood culture and no other focus of infection except the catheter. The disk diffusion technique was used to check similarity of strains and resistance to oxacillin. Of the 353 tips analyzed, 39 were included in this study as the inclusion criteria. The semiquantitative culture was positive in 26 (66.7%) catheters and quantitative culture was positive in 24 (61.5%). Of 273 patients, 19 (6.9%) had a diagnosis of catheter-related bloodstream Infection (CR-BSI). Of the 19 episodes of CR-BSI, S. epidermidis was the predominant etiological agent (84.2%). The resistance to the antibiotic methicillin was found in 14 (73.7%) strains of Staphylococcus. The semiquantitative method was more sensitive (79%) compared with the quantitative method (63%). The use of antibiotics may have influenced the sensitivity of the quantitative method as the microorganisms present in the lumen are exposed to higher concentrations of antibiotics administered via the catheter
Resumo:
Many studies inform that with aging process there’s a drop, not only in the cognitive functions, but also in the functional fitness. This drop can damage the old people’s daily activities, making them lose their independence. These declines can be softened with the practice of physical exercises. So, the aim of this study is to develop a systematic review in the literature which is the quantity of lectures done using the Square Stepping Exercise, we use a follow keyword “Square Stepping Exercise”. We performed a search in the following databases: PUBMED, Portal de Periódicos CAPES, Google Acadêmico e Catálogo Athena (acervo da Biblioteca de todos os campus da UNESP). Those procedures were complemented for manual searches in the references of the found lectures, like the access to the curriculum vitae, plataforma Lattes. There were analyzed articles, in Portuguese and English. Language were selected 11 studies (2 monografies, 1 masters lecture, 1 experience relatorie, 1 book chapter and 6 articles). The references found had improvement in motor and cognitive aspects. With this review, it was concluded that the SSE showed itself as a useful method to get better and/or maintain the analyzed aspects. It’s also necessary new studies with different populations, tips of analyse, periods of time and other aspects
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Molar-Incisor Hypomineralization (MIH) is a qualitative developmental enamel defect that affects one to four permanent first molars, with or without involvement of permanent incisors. Enamel defects may produce many symptoms that have physical, social and psychological effects and influence day-to-day living or quality of life. The available treatment modalities for teeth with MIH are extensive, ranging from prevention, restoration, to extraction. Factors such as age, patient expectations, severity of the lesion and materials should be considered in the treatment of the patient with MIH. Restoration with composite resin is an alternative choice for posterior and anterior MIH defective teeth and its use has been show acceptable results. This article describes two clinical cases involving pediatric patients with MIH whose procedure of cavity preparation was based on the use of CVD ultrasound diamond tips and restored using composite resin obtaining favorable esthetics results after a 1 year follow-up.
Resumo:
To evaluate the influence of different toothpaste abrasives on the bristle wear and bristle tip morphology of toothbrushes with different degrees of hardness. Material and methods Ninety samples of bovine incisor teeth were used in this study. The samples were randomly divided into three groups according to the bristle hardness of the toothbrush used: soft bristles (S); extra-soft bristles (ES); hard bristles (H). The toothbrushes of each group were randomly divided into six subgroups with five toothbrushes each, according to the abrasive of the toothpaste used in the simulation: Negative control (distilled water); toothpaste 1 (silica); toothpaste 2 (hydrated silica); toothpaste 3 (calcium carbonate, calcium bicarbonate and silica); toothpaste 4 (tetrapotassium pyrophosphate, silica and titanium dioxide); toothpaste 5 (calcium carbonate). The samples were placed in a toothbrushing simulating machine that simulating three months of brushing. The toothbrush bristles were evaluated by the bristle wear index, and the bristle tips morphology was evaluated by the bristle tip morphology index. Results The ES brush presented the highest bristle wear among the toothbrushes. Additionally, the S brushes showed better morphology of the bristles followed by ES and H brushes. The type of abrasive only influenced the bristle tip morphology of the ES brushes. The toothpaste 3 induced the worse bristle tip morphology than all the other toothpastes. Conclusions Different abrasives have influence only on the bristle tip morphology of the ES brushes.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
This study assessed the surface microhardness of compound resins cured by different light sources. Methods Three micro hybrid (Vit-l-escence, Amelogen Plus, Opallis) and one nanoparticle (Filtek Z350, 3M ESPETM Dental Products, St. Paul, USA) compound resins were selected. The resins were polymerized by a halogen light unit (Ultralux, Dabi Atlante, Ribeirão Preto, Brasil) with two tips, one semi-guided made of glass and another of painted acrylic and a LED-based source (UltraLume 2, Ultradent®, South Jordan, USA). Specimens constructed from a circular aluminum matrix were photopolymerized for 40 second after they received the compound resin and stored dry for 24 hours. After this period, a Vickers surface microhardness assay was performed, measuring the top (hardness 1) and base (hardness 2) surfaces four times each. Variance analyses were complemented by Newman-Keuls method, with significance set at 5%. Results The Opallis (FGM, Santa Catarina, Brasil) resin subjected to UltraLume 2 (Ultradent®, South Jordan, USA) obtained the lowest mean hardness values for the top surface. The Vit-l-escence (Ultradent®, South Jordan, USA) compound cured by Led UltraLume 2 (Ultradent®, South Jordan, USA) and by Ultralux PCP (Dabi Atlante, Ribeirão Preto, Brasil) halogen light obtained the highest mean hardness, followed by the Filtek Z350 (3M ESPETM Dental Products, St. Paul, USA) resin subjected to UltraLume 2 (Ultradent® South Jordan, USA). The Opallis (FGM, Santa Catarina, Brasil) resin cured by LED UltraLume 2 (Ultradent®, South Jordan, USA) also obtained the lowest mean hardness for the base surface and the Vit-L-Escence (Ultradent®, South Jordan, USA) resin obtained the highest value, followed by Amelogen Plus, when cured by Ultralux (Dabi Atlante, Ribeirão Preto, Brasil) using the semi-guided tip. Conclusion The polymerization and, consequently, the microhardness achieved by the LED unit was equivalent to those achieved by conventional halogen units for three of the four composites tested.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
ObjectivesTo evaluate the influence of different toothpaste abrasives on the bristle wear and bristle tip morphology of toothbrushes with different degrees of hardness.Material and methodsNinety samples of bovine incisor teeth were used in this study. The samples were randomly divided into three groups according to the bristle hardness of the toothbrush used: soft bristles (S); extra-soft bristles (ES); hard bristles (H). The toothbrushes of each group were randomly divided into six subgroups with five toothbrushes each, according to the abrasive of the toothpaste used in the simulation: Negative control (distilled water); toothpaste 1 (silica); toothpaste 2 (hydrated silica); toothpaste 3 (calcium carbonate, calcium bicarbonate and silica); toothpaste 4 (tetrapotassium pyrophosphate, silica and titanium dioxide); toothpaste 5 (calcium carbonate). The samples were placed in a toothbrushing simulating machine that simulating three months of brushing. The toothbrush bristles were evaluated by the bristle wear index, and the bristle tips morphology was evaluated by the bristle tip morphology index.ResultsThe ES brush presented the highest bristle wear among the toothbrushes. Additionally, the S brushes showed better morphology of the bristles followed by ES and H brushes. The type of abrasive only influenced the bristle tip morphology of the ES brushes. The toothpaste 3 induced the worse bristle tip morphology than all the other toothpastes.ConclusionsDifferent abrasives have influence only on the bristle tip morphology of the ES brushes.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.