216 resultados para Silicone elastomers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This conclusion thesis has the objective of produce substrates of Silicon Carbide from the powder of SiC for aerospace use. The powder of SiC was pressed in cylindrical form by the process called “wet way”. For the inicial pressing process was used a uniaxial squeezer and after that was used a isostatic squeezer, after that the samples were synthesized. The next step was the machining and polishing to improve the features of the surface of the sample. Then the roughness was measured, as also the Arquimedes method and optical microscopy and scanning eletron microscopy. Some innovations were done, in one of the lots little vacancys were done with organic material or silicon to reduce the weight of the sample; and the other innovation were the use of a slip film of SiC on the surface of the sample, that were after synthesized with LASER to reduce the roughness, in this samples the roughness were reduce in 50 % if compared with the other samples

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O acetato de dexametasona (DXM) é um glicocorticoide com eficácia antiinflamatória e imunossupressora, sendo utilizado nas doenças autoimunes. Sua ação antiinflamatória advém da inibição do acúmulo de células (macrófagos, linfócitos e neutrófilos) na área da inflamação, inibindo também a liberação de mediadores da inflamação como interferon-γ e TNF-α. Já a atividade imunossupressora é alcançada com a redução do concentrado de linfócitos e inibição da síntese e/ou liberação de interleucinas. Porém o uso contínuo do DXM ocasiona uma série de efeitos colaterais sistêmicos, sendo interessante sua aplicação tópica para viabilizar a promoção do aumento da liberação e a estabilização dos níveis plasmáticos do fármaco. Sistemas nanoestruturados como microemulsões (ME) e os cristais líquidos (CL) vêm sendo estudados como novos sistemas de liberação, pois além de se comportarem como reservatórios de fármacos também possibilitam o aumento da estabilidade e da solubilidade dos princípios ativos. Os objetivos deste trabalho foram desenvolver e caracterizar sistemas micro e nanoestruturados, com intuito de incorporar DXM e avaliar sua permeação cutânea in vitro. Foram desenvolvidos sistemas utilizando água, silicone (DC® 193C fluido) e polioxietileno-20-oleil éter (Brij® 98). Os 36 pontos do diagrama de fases foram avaliados, sendo elaboradas formulações com diferentes proporções de água, óleo e tensoativo, sendo possível delimitar regiões como: sistemas transparentes de alta viscosidade (STAV), sistemas transparentes de baixa viscosidade (STBV), sistemas líquido-transparentes (SLT), emulsão viscosa (EV) e emulsão líquida (EL). Três formulações foram selecionadas para os ensaios de caracterização, fixando-se a concentração de tensoativo (T) em 40% e variando-se as concentrações de água e de silicone, denominadas A, B e C. As análises de microscopia de luz polarizada ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A psoríase é uma doença inflamatória de pele e das articulações, e por acometer um órgão visível como a pele, resulta em transtornos psicológicos relacionados à auto-estima do paciente. Dentre os fármacos empregados no tratamento, destaca-se o metotrexato para uso sistêmico que, embora eficiente, possui a desvantagem de causar efeitos colaterais tóxicos como a hepatotoxicidade e a mielotoxicidade. Para minimizar tais efeitos e aumentar a eficácia do fármaco, o trabalho teve por objetivo desenvolver e caracterizar sistemas nanoestruturados para administração cutânea do metotrexato. Para realizar esse estudo, inicialmente foram preparadas diferentes formulações constituídas por silicone fluido de copolímero glicol (DC® 193), poliéter funcional siloxano (DC® 5329) e água destilada. O metotrexato foi incorporado numa concentração de 1,25% (p/v), com auxílio de solução de hidróxido de sódio 1M, sendo ajustado o pH final da formulação para 7,0 com ácido clorídrico 0,1M. Foram selecionadas algumas regiões do diagrama para serem submetidas a testes de estabilidade, empregando o teste de centrifugação, determinação do pH, condutividade iônica, índice de refração e avaliação das características organolépticas. Foi realizada a análise reológica empregando reômetro, modelo RS-1 (HaakeRheostress). As estruturas das formulações foram analisadas por microscopia de luz polarizada. As amostras com maior concentração de tensoativo apresentaram aspecto transparente, sendo submetidas à análise com microscópio de luz polarizada, onde evidenciou-se estruturas conhecidas como “cruzes de malta”, indicativas de fase lamelar. Foram selecionadas 3 formulações com concentração de 40% de tensoativo, variando-se as proporções de água e óleo, nas quais foram incorporadas o metotrexato... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to obtain plasma thin film composites with hydrophobic/hydrophilic alternated regions, which are useful for the production of miniaturized mixers. These regions were acquired by two different strategies: either the codeposition of TEOS and HFE plasma thin films or the exposition of TEOS plasma films to ultraviolet radiation (UVA and UVC). These films were characterized by several chemical and physical techniques. The refractive indexes vary from 1.4 to 1.7; infrared and photoelectron spectroscopy detect Si-O-Si and CHn species. Silicone-like structures with high or low number of amorphous carbon microparticles and with fluorinated organic clusters were produced. Cluster dimensions were in the 1-5 mm range and they are made of graphite or COF (carbon/oxygen/fluorine) compounds. Scanning electron and optical microscopy showed rough surfaces. Water contact angles were 90º; however, for TEOS films that value changed after 6 hr of UVC exposure. Moreover, after UV exposure, organic polar compounds could be adsorbed in those films and water was not. The passive mixer performance was simulated using the FemLab 3.2® program and was tested with 20 nm thick films on a silicon wafer, showing the capacity of these films to be used in such devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The synthetic intermaxillary elastic emerged as an alternative for clinical use in patients with latex sensitivity. However, there are disagreements about this elastic protocol use according to the force degradation. The aim of this study was to evaluate, in vitro, the forces generated by latex and synthetic elastics over time. Material and methods: Sample size of 840 elastics were used (420 latex and 420 synthetic), delivering medium strength (Dental Morelli®) with internal diameter of 1/8", 3/16", 1/4" and 5/16". The elastics were randomly divided into 7 groups according to the time of the force measuring and immersed into distilled water at 37°C. To measure the force in each group, the elastics were stretched in six progressive increases of 100% of its internal diameter with the aid of a testing machine Emic and measured up to 72 hours. Data were analyzed with SPSS 16.0, using one-way analysis of variance (ANOVA). Results: Immediate force level of synthetic elastics was statistically higher than latex elastics in all strains, for the same size. However, the latex elastics mean forceslightly decreased over time, while the synthetic elastics presented an abrupt decrease. Conclusion: In view of these findings, Sudanese homemade alcoholic beverages cause oral epithelial atypical changes, which lead to oral precancerous and cancerous lesions. OEFC is a useful procedure for detection and assessment of oral ET.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction and Objective: The synthetic intermaxillary elastic emerged as an alternative for clinical use in patients with latex sensitivity. However, there are disagreements about this elastic protocol use according to the force degradation. The aim of this study was to evaluate, in vitro, the forces generated by latex and synthetic elastics over time. Material and methods: Sample size of 840 elastics were used (420 latex and 420 synthetic), delivering medium strength (Dental Morelli®) with internal diameter of 1/8”, 3/16”, 1/4” and 5/16”. The elastics were randomly divided into 7 groups according to the time of the force measuring and immersed into distilled water at 37°C. To measure the force in each group, the elastics were stretched in six progressive increases of 100% of its internal diameter with the aid of a testing machine Emic and measured up to 72 hours. Data were analyzed with SPSS 16.0, using one-way analysis of variance (ANOVA). Results: Immediate force level of synthetic elastics was statistically higher than latex elastics in all strains, for the same size. However, the latex elastics mean force slightly decreased over time, while the synthetic elastics presented an abrupt decrease. Conclusion: The synthetic elastic presented severe force degradation, jeopardizing the cost-benefit ratio, which indicates a higher replacement frequency. The latex elastic showed better mechanical performance in comparison to synthetic ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the force degradation of synthetic elastics over time using dynamic biomechanical tests in order to find clinical parameters of what size of elastic and frequency of exchange should be used in orthodontic therapy. It was used 240 elastics of Dental Morelli, sizes 1/8", 3/16", 1/4 "and 5/16", medium force, divided in four groups. In each group was measured forces at different times, from immediate to 72 hours after immersion in water at 37°C and incubated stretched to 600% of its initial inner diameter. Tensile tests were performed on a universal testing machine EMIC DL2000 submerged in distilled water maintained at 37°C. Data were analyzed using SPSS version 16.0, by the Analysis of Variance (One-Way) with Tukey´s post test. There was a greater increase in pattern of force decay of immediate measurement until 24 hours in all sizes of synthetic elastics, from which it was observed a decrease in force progressively smaller, with the exception of 5/16´´ elastic with a maximum force decay occurred at 12h. It was concluded that: the elastic synthetic Dental Morelli suffered significant force degradation over time, with reduction of approximately 70% of the initial force during 24 hours of stretching, followed by a progressively smaller decrease; the amount of stretch for a ideal force in intermaxillary therapies depends on the distance between the points of attachment of elastic, being necessary to consult the tables to choose the size, force and frequency of replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: the oral rehabilitation in edentulous patients using removable complete dentures is a classic treatment, easily accessible, and presenting satisfactory results. However, to succeed in this type of treatment, stability is an extremely important factor. The neutral zone technique for the production of complete dentures determines the oral cavity space for the positioning of teeth and denture base that provide a neutralization of the forces delivered by lips, cheeks, and tongue, providing better stability and retention of prostheses, which is indicated in cases with history of difficulties in adapting the conventional mandibular denture. Objective and case report: this paper aimed to describe a clinical case report of the oral rehabilitation of a patient with paraprosthetic muscles hypertonicity through removable complete dentures produced by the neutral zone technique, using condensation silicone. Final considerations: the use of condensation silicone for the development of the neutral zone technique showed to be a good alternative for the development of this clinical case, providing satisfactory stability and retention of the complete mandibular denture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The retromolar triangle is a triangular area located in the mandible, posteriorly to the last molar. This region, due its thickness and bone density, is widely used for the installation of devices that provide an anchorage system for the movement of the lower molars. The aim of this research is to provide morphometric data of the mucosa thickness of the retromolar triangle. Twenty-five patients of portuguese nationality, with indication for extraction of the impacted lower third molar (right and/or left), were studied. In the region of the retromolar triangle were demarcated 3 points corresponding to the vertices of a triangle whose the base was torned for the distal face of the lower third molar and the lenght of the sides corresponded to vestibulolingual dimension of the same tooth, then was demarcated a fourth point corresponding to the geometric center of the triangle. Then, using a finger spreader with silicone stop were measured the mucosal tickness at each point. The data obtained were tabulated and analyzed. The lowest average value found was 5.5mm on the right side and the highest average value found was 7.13mm on the left side. Considering the mean values obtained at the points of the retromolar triangle mucosa measured in this study, we conclude that the retromolar triangle shows thick mucosa, so the mini-implants indicated for this region should have a long transmucosal neck.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this work was to mount and test an experimental model to measure the hydraulic conductance of ex vivo dentin. Seventeen healthy third molars, with indication of extraction of healthy donors aged between 15 and 30 years were obtained by informed consent. After cleaning them, disinfecting them, including them in resin epoxy and cutting them, there were 17 samples of dentin, corresponding to a disk of resin with a coronal section of tooth showing the dentin exposed on both sides of it. Three machines to measure the hydraulic conductance of the dentin were assembled according to the description of the model of Pashley. Samples were installed in a Chamber of diffusion, connected by using silicone tubes to a graduated transfer pipette and a 20cm water column. Through the displacement of a bubble of water in the inside of the pipette, the hydraulic conductance of each sample was measured 3 times on the 14th, 21st, 28th and 35th day post extraction. The data were tabulated and analyzed statistically. There is no SS difference in the rate of flow of a measured sample in the three machines (p=0.5937). There is no SS difference in measurements of the hydraulic conductance of 13 samples of human dentin measured in days 14, 21, 28 and 35 postextraction (p=0.0704). It is possible to mount an experimental model to study the hydraulic conductance of dentin ex vivo, based on the model of Pashley. The model seems to be reliable, but more research is needed in order to validate its reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to demonstrate through a case report, a proposed treatment for discolored teeth, with and without pulp vitality, by the technique of external and internal tooth bleaching with hydrogen peroxide to 35% Lase Peroxide Sensy (DMC) using Whitening Lase II Device (DMC), and a silicone guide (3M ESPE) in the palatine portion of the upper teeth. In this clinical case, the patient had darkened dental elements 11 and 22, and dissatisfaction with the coloring of other elements. It was observed that the techniques used and the materials chosen allowed for an excellent aesthetic result, with technical simplicity and low cost, and minimal occurrence of signs and symptoms

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)