215 resultados para SMALL ANGLE SCATTERING


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The sol-gel process is a method for obtaining vitreous or vitro-ceramic materials which, are prepared a sol and by drying the liquid phase. This technique has been used extensively for the preparation of glassy gels, films, fibers and particles from the hydrolysis and polycondensation reactions of metal alkoxides. The usual methods for drying are: evaporation drying (xerogels), freeze drying (criogéis) and via supercritical CO2 extraction (aerogels). In the present work, we studied the preparation of silica gels by the sol-gel process from the hydrolysis of alkoxides tetraethylorthosilicate (TEOS) and 3-glycidoxypropyltrimethoxysilane (GPTS). The hydrolysis was promoted from GPTS and TEOS in proportion (4: 1) under acidic conditions. The hydrolysis reaction was promoted inside a Becker at room temperature. After hydrolyses the prepared sol had pH 2, and kept under mechanical agitation for a period of 1 hour. In order to accelerate the polycondensation reaction, the pH was corrected to a value near 5 by slowly adding NH4OH. Then the sols were leaked in sealed polycarbonate containers and maintained for 20 days at 40°C for gelation. Silica aerogels were prepared via supercritical CO2 extraction of the wet gel at temperature and pressure higher than 31°C and 74 atm, in an autoclave specially developed for the process. The structural characteristics were studied in the dry gel (aerogel). Aerogels were then characterized by nitrogen adsorption and small angle light scattering. The nitrogen adsorption data were analyzed for the determination of the BET specific surface (SBET), the total pore volume Vp, the pore mean size (lP=4Vp/SBET), the particle mean size (lS) and the pore size distribution (PSD). And the data from small angle light scattering were analyzed to determine the correlation function (γ'), the area per unit volume (S/V), average pore size (l ) and the average particle size...

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Topical corticosteroids, e.g., dexamethasone acetate (DMA), are extensively used to treat cutaneous inflammatory disorders even though their use is correlated with potential local and systemic side effects. The objective of this study was to develop and test the topical delivery of DMA-loaded surfactant based systems in vitro; these studies could guarantee a suitable delivery and therapeutic efficacy, as well as minimize DMA's side effects. A phase diagram was constructed using polyoxypropylene (5) polyoxyethylene (20) cetyl alcohol as the surfactant (S), isopropyl myristate as the oil phase (O) and water (W). The systems were characterized using polarization light microscopy (PLM), as well as rheological and small angle X-ray scattering (SAXS) measurements. Depending on the concentration of the constituents, it was possible to obtain microemulsions (MEs) and liquid crystalline mesophases (lamellar and hexagonal). These types of arrangement were verified using PLM measurements. The SAXS results revealed that increasing the W/S ratio led to ME, as well as lamellar (LAM) and hexagonal (HEX) arrangements. The MEs displayed typical Newtonian behavior while the LAM and HEX phases exhibited pseudoplasticity and plasticity, respectively. The MEs displayed excellent drug solubilization that was approximately 10-fold higher than was observed with the individual components. The in vitro cutaneous permeation studies using pig ear skin and analysis of the mechanical parameters (hardness, compressibility, cohesiveness and adhesiveness) were carried out with a HEX phase and O/W emulsion. The HEX phase achieved better drug permeation and retention in the skin while its mechanical properties were suitable for skin administration. PPG-5-CETETH-20-based systems may be a promising platform delivering DMA and other topical corticosteroids through the skin.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We studied the effect of silica surface on luminescence properties of terbium complex by spectroscopy characterization, where microparticles of mesoporous silica type MSU-X was prepared. We used silica with different surface: calcined, washed, functionalized with 3- aminopropyl-triethoxysilane (APTES), and 3-glycidoxypropyl-trimethoxysilane (GPTMS); impregnated with Tb3+-glutamic acid complex. The obtained materials were characterized by scanning electron microscopy, porosity measurements, small-angle X-ray scattering, as structural characterization; Fourier transform infrared and luminescence spectroscopy, as spectroscopy characterization. Finally, we observed that functional groups at the silica surface lead to changes on luminescent properties of the final materials. The observed shift of the absorption and emission bands can be assigned to the effect of the functional groups of mesoporous silica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The tractors are the main potency source, for the traction of tillage equipments and their use are increasing more and more in Brazilian agriculture. In spite of the great technological progress the increase of the number of agricultural tractors brought positive aspects and some negative, among these last ones it stands out the appearance of a new source of work accidents, which importance is given by the physical damages caused to the operator. Therefore the objective of this work was to project and develop an inclinometer, which indicates the inclination of the land, as safety sensor for agricultural tractors to avoid lateral hollovers, through a resonant sign, for the operator and the machine preservation. The built and evaluated inclinometer showed to be efficient for inclination indication of different areas during field operations with agricultural tractors, small angle oscillation and enough answer time to help operators to take decisions in imminence situation of lateral machine hollovers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An investigation is made of the influence from small amounts of the protein bovine serum albumin (BSA) on the lateral organization of low molecular weight surfactant sodium bis-2-ethylhexyl sulfosuccinate (AOT) at the air-water interface. Surface pressure (pi - A), surface potential (DeltaV - A) and Brewster angle microscopy (BAM) experiments were carried out, with particular emphasis on the monolayer stability under successive compression-expansion cycles. AOT monolayer is not stable at the air-water interface, which means that the majority of AOT molecules go into the aqueous subphase as monomers and/or normal micelles. When a waiting time elapses between spreading and compression, the surfactant monolayer tends to reorganize partially at the air-water interface, with a monolayer expansion being observed for waiting times as large as 12 h. The incorporation of very small amount of BSA (10(-9) M) at the interface, also inferred from BAM, increases the monolayer stability as revealed by pi - A and DeltaV - A results. For a waiting time of circa 3 h, the mixed monolayer reaches its maximum stability. This must be related to protein (and/or protein-surfactant complexes) adsorbed onto the AOT monolayer, thus altering the BSA conformation to accommodate its hydrophobic/hydrophilic residues. Furthermore, the effects from such small amounts of BSA in the monolayer formation and stabilization mean that the AOT monolayer responds cooperatively to BSA. (C) 2004 Elsevier B.V. All rights reserved.