401 resultados para Parâmetros físicos do solo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radiotherapy is a field of medical physics, which has been going through a scientific and technological advancement, it is extreme important the professionals that work in this area continuous their study to improve the quality of service provided. For it, they should know the physical principles related as well their employment in radiotherapy. The electrons have been using in therapy of superficial tumors, because they show rapid decrease of dose in depth, they don’t expose the deeper tissues to radiation. The electron therapy has replaced the surface therapy with x-ray and mold brachytherapy, and nowadays, it represents 10 to 15% of radiotherapy treatments. This study brings the definition of physical parameters used in the dosimetry of electron beam, describes the tests for quality control of linear accelerator with a electrons beam, as well the activities realized in the Radiotherapy Division, of Hospital de Clinicas, in the Universidade Estadual of Campinas, in the Clinac 2100C machine

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The treatment of a tumor with ionizing radiation is an ongoing process with well differentiated stages. These ones include the tumor diagnosis and location, the decision on the treatment strategy, the absorbed dose planning and calculation, the treatment administration, the absorbed dose verification and the evaluation of results in short and long terms. The quality of a radiotherapy procedure is closely linked to factors that may be classified as clinical, such as the diagnosis, the tumor location, the treatment strategy chosen and the continuous treatment reassessment; dosimetric or physical, such as the uncertainty in the dose calculation, its optimization and verification, the suitability of the equipment to provide a radiation beam consistent with the treatment planning; finally, others which are related to the practical application of radiotherapy treatment and the handling of the patient. In order to analyze the radiotherapy quality, one should realize that the three aspects (medical, physical or dosimetric and practical application) should be considered in a combined way. This means that numerous actions of the radiotherapists, medical physicists and technicians in radiotherapy should be held jointly and their knowledge level will significantly affect the treatment quality. In this study, the main physical parameters used in dosimetry are defined as well as determined experimentally for a linear accelerator Mevatron - MXT. With this, it is intended to provide recommendations for the physical aspects of Quality Assurance (QA) in the radiotherapy treatments, and these will usually be applied by professionals in Medical Physics. In addition to these instructions, it is recommended that additional texts are prepared to address in detail the clinical aspects of the treatments QA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This project has several objectives: To determine medium values and variations of the density, porosity, humidity, shrinkage volume and the coefficient of mass attenuation of gamma radiation of 59,6 keV of the radioisotope 241Am, using samples of equine radio, in growth and adult. The samples of bones were supplied by the Department of Pathology of University of Veterinary Medicine and Zootechnics - UNESP campus Botucatu. Bones of the paws front left of two males were used. Of each bone ten samples were removed. Those samples were prepared to just obtain compact bony fabric, being submitted to the rehearsal of determination of the density by the immersion method in water and determination of the coefficient attenuation lineal for the method of attenuation of the radiation of the 241Am, also obtaining your humidity content. Still, they were obtained new samples starting from the ground samples and verified the density of the particles present in that, obtaining the medium value of the coefficient of mass attenuation. The results showed the medium values and significant statistical variations of the density, porosity, humidity, shrinkage volume and coefficient of mass attenuation of gamma radiation of 59, 6 keV of the radioisotope 241Am in the samples, establishing some relationships between of the certain physical parameters with biological aspects and possible existent influences between them

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper conducts to water quality study of Stream Guaratinguetá from its source to its confluence with the River Paraiba, through the analysis of some physical, chemical and biological parameters. All tests were performed according to Standard Methods for Examination of Water and Wastewater 20th edition and compared to the CONAMA Resolution No. 357 (2005). Coliforms was the most critical parameter found in samples. The results lead to the conclusion that the biggest problem of water quality in the stream in study is the aquatic rice (rice field) and the launch “fresh” sewage

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work we study some topics of Celestial Mechanics, namely the problem of rigid body rotation and “spin-orbit” resonances. Emphasis is placed on the problem formulation and applications to some exoplanets with physical parameters (e.g. mass and radius) compatible with a terrestrial type constitution (e.g. rock) belonging to multiple planetary systems. The approach is both analytical and numerical. The analytical part consists of: i) the deduction of the equation of motion for the rotation problem of a spherical body with no symmetry, disturbed by a central body; ii) modeling the same problem by including a third-body in the planet-star system; iii) formulation of the concept of “spin-orbit” resonance in which the orbital period of the planet is an integer multiple of the rotation’s period. Topics of dynamical systems (e.g. equilibrium points, chaos, surface sections, etc.) will be included at this stage. In the numerical part simulations are performed with numerical models developed in the previous analytical section. As a first step we consider the orbit of the planet not perturbed by a third-body in the star-planet system. In this case the eccentricity and orbital semi-major axis of the planet are constants. Here the technique of surface sections, widely used in dynamical systems are applied. Next, we consider the action of a third body, developing a more realistic model for planetary rotation. The results in both cases are compared. Since the technique of disturbed surface sections is no longer applicable, we quantitatively evaluate the evolution of the characteristic angles of rotation (e.g. physical libration) by studying the evolution of individual orbits in the dynamically important regions of phase space, the latter obtained in the undisturbed case

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In radiation theraphy with electron beam, the electrons are produced in linear accelerators, and energy the most used have between 4MeV and 20MeV. Generally, the treatments are done for superficial injuries, because the low penetration of these particles. In this work a system for calculation of monitor units (U.M.) for cases of treatments with electron beam was developed. The Excel program of Microsoft was used and is easily found in the operational system of the personal microcomputers. In the Excel has been inserted the pertinent data of the linear accelerator of Varian, model 2100C, used in the Service of radiation theraphy of the Hospital of the Clinics of the College of Medicine of the UNESP of Botucatu. For some values of the physical parameters, such as: factors field and factors calibration, not supplied in the tests of acceptance of the machine, still proceeded calculations from interpolation and extrapolation. The mathematical formulas for automatic search of these and others factors used in the calculations of the determination of the U.M had been developed in agreement available routines in Excel. For this the functions had been used the function IF (that it imposes search condition) and the PROCH (that looks a value in a column from determined line), beyond the basic functions of addition, multiplication and division. It is intended to optimize the routine of the Services of radiation theraphy that perform through eletrontheraphy procedures, speeding the calculations and minimizing the occurrence of errors and uncertainties deriving of the maken a mistake manipulation of the parameters gotten in tables of data of electron beams

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The pharmaceutical innovations, such as the use of polymers to control drug release, create possibilities for a better action of the drug in the body, which causes a a more effective therapeutic effect and a safer treatment for the patient. In this work, were prepared and characterized matrix tablets of hydroxypropylmethylcellulose (HPMC) containing nimesulide as model drug to evaluate the performance as a controlled release system. HPMC, a cellulose ester, is a hydrophilic polymer that undergoes swelling, i.e., absorbs water and forms a gel layer controlling drug release. The characterization of powders was performed by analysis of particle size and morphology, density, compressibility index determination, flow properties and determination of swelling profile. The tablets were evaluated according to their physical parameters of quality and to the in vitro release of nimesulide, as well as the analysis of the mechanisms of drug release by appropriate mathematical models. The set of results showed that the HPMC/Nimesulide mixture exhibited satisfactory physical characteristics (size, shape, density and flow). The release profile demonstrated an effective control upon drug release in enteric environment and presented more correlation with Korsmeyer-Peppas’ and Weibull’s mathematical models, indicating that the release of nimesulide occurs through the relaxation of the polymer chains

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The work is to study about the quality of surface waters of the Piaguí and neighborhoods Colonia Santa Luzia. Six samples of which the physical, chemical and biological parameters were analyzed were collected. The tests were conducted in accordance with Standard Methods for the Examination of Water and Wastewater 20th edition and compared with the resolution of CONAMA No. 357 (2005). Critical parameters are found in fecal coliform and water coloring, which may indicate an anthropogenic interference in the sampling points (domestic sewage), or the effect of rainfall during the collection period influence the results

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Studies regarding the quality and quantity of water have become more and more important because of the increasing negative environmental impacts occurred and their scarcity increase as well. At the Center of Tropical Fish Research (Centro de Pesquisas de Peixes Tropicais - CEPTAlIBAMA) located in the city of Pirassununga, SP, there is a dam named Represa Velha which supplies 128 tanks that are fish hatcheries. This dam takes in part of the Barrinha stream micro-basin where it has been observed strong impacts due to the deforestation of its support forest, as well an the intensive agricultural activities in the neighboring areas. There has been established and distributed 13 points of water-collectors disposed inside the stream and the dam. The water samples were taken from the stream only from its surface because of the low depth and, inside. In the dam, the water samples were taken at the water column, at a 50cm distance over the sediment. In every point of collection inside the dam, it was placed a chamber of sedimentation, vertically in the water column at a 70% height from the total depth. The collections took place during the dry/cold and raining/warm periods of the years 2000 and 2001. Then, it were analyzed the physical, physical-chemical, chemical and micro-biological parameters of the water samples. The obtained results were statistically analyzed throughout the SAS system (Statistical Analisys System). Parameters such as total phosphate, nitrate, nitrite and turbidity were within the established limits for the Class 2 water, according to the n° 20/1986 CONAMA Resolução. However, the total and Escherichia coli coliforms, mainly inside the Barrinha stream, had showed values above of the established limits for the same... (Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV