215 resultados para Nonlinear vibration isolation system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a strategy to control nonlinear responses of aeroelastic systems with control surface freeplay. The proposed methodology is developed for the three degrees of freedom typical section airfoil considering aerodynamic forces from Theodorsen's theory. The mathematical model is written in the state space representation using rational function approximation to write the aerodynamic forces in time domain. The control system is designed using the fuzzy Takagi-Sugeno modeling to compute a feedback control gain. It useds Lyapunov's stability function and linear matrix inequalities (LMIs) to solve a convex optimization problem. Time simulations with different initial conditions are performed using a modified Runge-Kutta algorithm to compare the system with and without control forces. It is shown that this approach can compute linear control gain able to stabilize aeroelastic systems with discontinuous nonlinearities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of the present study was to evaluate the effect of pursed-lip breathing (PLB) on cardiac autonomic modulation in individuals with chronic obstructive pulmonary disease (COPD) while at rest. Methods: Thirty-two individuals were allocated to one of two groups: COPD (n = 17; 67.29 +/- 6.87 years of age) and control (n = 15; 63.2 +/- 7.96 years of age). The groups were submitted to a two-stage experimental protocol. The first stage consisted of the characterization of the sample and spirometry. The second stage comprised the analysis of cardiac autonomic modulation through the recording of R-R intervals. This analysis was performed using both nonlinear and linear heart rate variability (HRV). In the statistical analysis, the level of significance was set to 5% (p = 0.05). Results: PLB promoted significant increases in the SD1, SD2, RMSSD and LF (ms(2)) indices as well as an increase in alpha(1) and a reduction in alpha(2) in the COPD group. A greater dispersion of points on the Poincare plots was also observed. The magnitude of the changes produced by PLB differed between groups. Conclusion: PLB led to a loss of fractal correlation properties of heart rate in the direction of linearity in patients with COPD as well as an increase in vagal activity and impact on the spectral analysis. The difference in the magnitude of the changes produced by PLB between groups may be related to the presence of the disease and alterations in the respiration rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of poorly treated water during hemodialysis may lead to contamination with nontuberculous mycobacteria (NTM). This study aimed to isolate and identify NTM species in the water of a Brazilian hemodialysis center. We collected 210 samples of water from the hydric system of the unit (post-osmosis system, hemodialysis rooms, reuse system, and hemodialysis equipment) and from the municipal supply network; we isolated the NTM by a classic microbiological technique and identified them by the PCR restriction enzyme pattern of the hsp65 gene (PRA). Fifty-one (24.3 %) of the collected samples tested positive for NTM; both the municipal supply network (2 samples, 3.2 %) and the hydric system of the hemodialysis center (49 samples, 96.1 %) contained NTM. We isolated and identified potentially pathogenic bacteria such as Mycobacterium lentiflavum (59.0 %) and M. kansasii (5.0 %), as well as rarely pathogenic bacteria like M. gordonae (24.0 %), M. gastri (8.0 %), and M. szulgai (4.0 %). The ability of NTM to cause diseases is well documented in the literature. Therefore, the identification of NTM in the water of a Brazilian hemodialysis center calls for more effective water disinfection procedures in this unit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an experimental study into the vibration control of a servo system comprising a servo motor and a flexible manipulator. Two modes of the system are controlled by using the servo motor and an accelerometer attached to the tip of the flexible manipulator. The control system is thus non-collocated. It consists of two electrical dynamic absorbers, each of which consists of a modal filter and, in case of an out-of-phase mode, a phase inverter. The experimental results show that each absorber acts as a mechanical dynamic vibration absorber attached to each mode and significantly reduces the settling time for the system response to a step input.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Critical exponents that describe a transition from unlimited to limited diffusion for a ratchet system are obtained analytically and numerically. The system is described by a two dimensional nonlinear mapping with three relevant control parameters. Two of them control the non-linearity while the third one controls the intensity of the dissipation. Chaotic attractors appear in the phase space due to the dissipation and considering large non-linearity are characterised by the use of Lyapunov exponents. The critical exponents are used to overlap different curves of average momentum (dynamical variable) onto a single plot confirming a scale invariance. The formalism used is general and the procedure can be extended to different systems.