268 resultados para Maxillofacial prosthesis implantation
Resumo:
The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.
Resumo:
Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.
Resumo:
This research evaluated the bone repair process after implantation of homogenous demineralized dentin matrix (HDDM) in surgical defects in the parietal bone of rabbits with alloxan-induced diabetes, using a polytetrafluorethylene (PTFe) barrier for guided bone regeneration. Thirty-six rabbits were used and divided into four groups: control (C, n = 12), diabetic (D, n = 12, left parietal bone), diabetic with PTFe (DPTFe, same 12 rabbits, right parietal bone), and diabetic with PTFe associated to HDDM (D-PTFe+HDDM, n = 12). Bone defects were created in the parietal bone of the rabbits and the experimental treatments were performed, where applicable. The rabbits were sacrificed after 15, 30, 60 and 90 days. The bone defects were examined radiographically and by optical density (ANOVA and Tukey test, p < .05). The radiographic findings showed that the D-PTFe+HDDM group presented greater radiopacity and better trabecular bone arrangement when compared to that of the C, D and D-PTFe groups. The statistical analysis showed significant differences in the optical density of the newly formed bone among the studied groups. It was possible to conclude that HDDM was biocompatible in diabetic rabbits.
Resumo:
The technique presented in this article presents a protocol for treatment that reduces the time required for the fabrication and placement of an implant supported prosthesis. It also offers improved patient comfort at a lower cost when compared to conventional technology.
Resumo:
Background: Previous studies have shown that membrane elevation results in predictable bone formation in the maxillary sinus provided that implants can be placed as tent poles. In situations with an extremely thin residual crest which impairs implant placement, it is possible that a space-making device can be used under the sinus membrane to promote bone formation prior to placement of implants. Purpose: The present study was conducted to test the hypothesis that the use of a space-making device for elevation of the sinus membrane will result in predictable bone formation at the maxillary sinus floor to allow placement of dental implants. Materials and Methods: Eight tufted capuchin primates underwent bilateral sinus membrane elevation surgery, and a bioresorbable space-making device, about 6 mm wide and 6 mm in height, was placed below the elevated membrane on the sinus floor. An oxidized implant (Nobel Biocare AB, Gothenburg, Sweden) was installed in the residual bone protruding into the created space at one side while the other side was left without an implant. Four animals were sacrificed after 6 months of healing. The remaining four animals received a second implant in the side with a space-making device only and followed for another 3 months before sacrifice. Implant stability was assessed through resonance frequency analysis (RFA) using the Osstell™ (Osstell AB, Gothenburg, Sweden) at installation, 6 months and 9 months after the first surgery. The bone-implant contact (BIC) and bone area inside the threads (BA) were histometrically evaluated in ground sections. Results: Histologically there were only minor or no signs of bone formation in the sites with a space-making device only. Sites with simultaneous implant placement showed bone formation along the implant surface. Sites with delayed implant placement showed minor or no bone formation and/or formation of a dense fibrous tissue along the apical part of the implant surface. In the latter group the apical part of the implant was not covered with the membrane but protruded into the sinus cavity. Conclusions: The use of a space-making device, with the design used in the present study, does not result in bone formation at the sinus floor. However, membrane elevation and simultaneous placement of the device and an implant does result in bone formation at the implant surface while sites with implants placed 6 months after membrane elevation show only small amounts of bone formation. It is suggested that lack of stabilization of the device and/or a too extensive elevation of the membrane may explain the results. © 2009, Wiley Periodicals, Inc.
Resumo:
The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.
Resumo:
Nowadays, aesthetics is very appreciated in the social context and a attractive smile is the object of desire in most of patients requiring prosthesis treatment. In case of removable prosthesis, total or partial, this feature is more significant since some or all teeth may be absents. Implants leading to a significant improvement in relation to function and comfort of removable prosthesis users, but the aesthetics of these prostheses had little attention in the current scientific literature. Thus, the aim of present article was to make a review of the literature on the aesthetic features related to rehabilitation with removable prostheses. In present study we found as significant factors for the aesthetics in removable partial and total prostheses: Selection of artificial teeth and their arrangement, characterization of acrylic resin basis and also the types and location of retainers for the removable partial prostheses. We conclude that the involvement and the aesthetic knowledge during the appropriate planning of this process is responsibility of the professional.
Resumo:
This paper presents an individual designing prosthesis for surgical use and proposes a methodology for such design through mathematical extrapolation of data from digital images obtained via tomography of individual patient's bones. Individually tailored prosthesis designed to fit particular patient requirements as accurately as possible should result in more successful reconstruction, enable better planning before surgery and consequently fewer complications during surgery. Fast and accurate design and manufacture of personalized prosthesis for surgical use in bone replacement or reconstruction is potentially feasible through the application and integration of several different existing technologies, which are each at different stages of maturity. Initial case study experiments have been undertaken to validate the research concepts by making dimensional comparisons between a bone and a virtual model produced using the proposed methodology and a future research directions are discussed.
Resumo:
Background: This article describes a clinical report with a new system for guided surgical treatment and immediate load prosthesis in the flapless surgical technique. Case report: Based on a computed tomography (CT) of a 64 - year-old edentulous patient, the cross sections were reformatted and used to construct a virtual planning of the implants and a guide template in Dental Slice. Six dental implants were placed in the maxilla and mandible using a Slice Guide System. Following a 30-month in maxilla and 24-month in mandible healing period, the clinical and radiographic evaluation and computed tomography (CT) showed good clinical stability. The Slice Guide System proved satisfactory for the Flapless Surgical Technique in dental implants.
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.
Resumo:
Background : Deep venous thrombosis (DVP) is a frequent disease. Prophylaxis is the best means to reduce its incidence, for lowering morbidity and mortality rates and treatment costs caused by its complications. Objective : To evaluate the knowledge and use of any kind of DVT prophylaxis by Brazilian Oral and Maxillofacial surgeons. Materials and Methods : A questionnaire was sent to all Oral and Maxillofacial surgeons associated to the Brazilian College of Oral and Maxillofacial Surgeons that have a valid e-mail address. The data retrieved was evaluated and tabulated. Results : Of the 1100 questionnaires sent, only 4% were retrieved. The 42 retrieved were included in the study. Twenty six of the surgeons do not use any kind of deep venous thrombosis (DVT) prophylaxis, 11 use mechanical means as elastic compressive stockings or pneumatic compressive devices for prophylaxis, and 5 uses low-molecular weight heparins (LMWH) as the choice for prophylaxis. Conclusion : The data collected, despite the low rate of participation (4%) by the surgeons, shows that this subject still does not receive proper attention. Whereas other medical specialties make routine use of prophylactic means maybe the maxillofacial surgeons lack concern on that matter.
Resumo:
The increased use of orofacial fillers in cosmetic procedures has led to new diagnostic challenges for dentists and oral pathologists. Here, we describe a case with multiple oral foreign body granulomas, which were formed after a polymethylmetacrylate injection for cosmetic purposes. © 2011 European Association for Cranio-Maxillo-Facial Surgery.