590 resultados para Maxillofacial prostheses
Resumo:
Purpose: To identify the trend of authorship in dental implant by exploring the prevalence of coauthored articles and to investigate the collaboration efforts, trends in funding involved in original articles, and their relationships. Materials: Articles published in the Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each included articles, number of authors, collaboration efforts, and extramural funding were recorded. Descriptive and analytical statistics (alpha = 0.05), including logistic regression analysis and chi(2) test, were used. Results: From a total of 2085 articles, 1503 met the inclusion criteria. Publications with 5 or more authors increased over time (P = 0.813). The amount of collaboration among different disciplines, institutions, and countries all increased. The greatest increase of collaboration was seen among institutions (P = 0.09). Non-funding studies decreased over time (P = 0.031). There was a strong association between collaboration and funding for the manuscripts during the years studied (OR, 1.5). Conclusion: The number of authors per articles and collaborative studies increased over time in implant-related journals. Collaborative studies were more likely to be funded. (Implant Dent 2011;20:68-75)
Resumo:
The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to present a literature review about photoelasticity, a laboratory method for evaluation of implants prosthesis behavior. Fixed or removable prostheses function as levers on supporting teeth, allowing forces to cause tooth movement if not carefully planned. Hence, during treatment planning, the dentist must be aware of the biomechanics involved and prevent movement of supporting teeth, decreasing lever-type forces generated by these prosthesis. Photoelastic analysis has great applicability in restorative dentistry as it allows prediction and minimization of biomechanical critical points through modifications in treatment planning.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The use of craniofacial implants is an effective treatment for patients with deformities, burns, and cancer sequelae. The sites with the most successful implants are the auricular, nasal, and orbital regions. Furthermore, other factors can affect the implant longevity such as irradiated area, surgical technique, bone quality and quantity, macrostructure and microstructure of the implant, maintenance, and systemic factors.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study evaluated the affect of disc displacement and articular disc repositioning on stability after surgical counterclockwise rotation and advancement of the maxillomandibular complex.Patients and Methods: A total of 72 patients (59 females, 13 males), with an average age of 30 years (range, 15 to 60 years) were evaluated. The patients were divided into 3 groups. Group 1 (G1; n = 21), with healthy temporomandibular joints (TMJs), underwent double jaw surgery only. Group 2 (G2; n = 35), with articular disc dislocation, underwent articular disc repositioning using the Mitek anchor (Mitek Surgical Products, Westwood, MA) technique concomitantly with orthognathic surgery. Group 3 (G3; n = 16), with articular disc dislocation, underwent orthognathic surgery only. Average postsurgical follow-up was 31 months. Each patient's lateral cephalograms were traced, digitized twice, and averaged to estimate surgical changes and postsurgical stability.Results: After surgery, the occlusal plane angle was decreased significantly in all 3 groups: by -6.3 +/- -15.0 degrees in G1, by -9.6 +/- 4.8 degrees in G2, and by -7.1 +/- 4.8 degrees in G3. The maxillomandibular complex was advanced and rotated counterclockwise similarly in all 3 groups, with advancement at the menton of 12.4 +/- 5.5 mm in G1, 13.5 +/- 4.3 mm in G2, and 13.6 +/- 5.0 mm in G3; advancement at the B point of 9.5 +/- 4.9 mm in G1, 10.2 +/- 3.7 mm in G2, and 10.8 +/- 3.7 mm in G3; and advancement at the lower incisor edge of 7.1 +/- 4.6 mm in G1, 6.6 +/- 3.2 mm in G2, and 7.9 +/- 3.0 mm in G3. Postsurgery, the occlusal plane angle increased in G3 (2.6 +/- 3.8 degrees; 37% relapse rate) but remained stable in G1 and G2. Postsurgical mandibular changes in the horizontal direction demonstrated a significant relapse in G3 at the menton (-3.8 +/- 4.1 mm; 28%), the B point (-3.0 +/- 3.4 mm; 28%), and the lower incisor edge (-2.3 +/- 2.1 mm; 34%) but remained stable in G1 and G2.Conclusions: Maxillomandibular advancement with counterclockwise rotation of the occlusal plane is a stable procedure for patients with healthy TMJs and for patients undergoing simultaneous TMJ disc repositioning using the Mitek anchor technique. Those patients with preoperative TMJ articular disc displacement who underwent double-jaw surgery and no TMJ intervention experienced significant relapse. (C) 2008 American Association of Oral and Maxillofacial Surgeons.
Resumo:
Purpose: the purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the mandibles of Cebus apella monkeys and filled with autogenous bone, PerioGlas, FillerBone, or Bone Source. Materials and Methods: Surgical cavities 5 mm in diameter were prepared through both mandibular cortices in the mandibular angle region. The cavities were randomly filled, and the animals were divided into groups according to the material employed: Group 1 cavities were filled with autogenous corticocancellous bone; group 2 cavities were filled with calcium phosphate cement (BoneSource); and group 3 and group 4 cavities were filled with bioactive glass (FillerBone and PerioGlas, respectively). After 180 days the animals were sacrificed, and specimens were prepared following routine laboratory procedures for hematoxylin/eosin staining and histologic evaluation. Results: the histologic analysis showed that autogenous bone allowed total repair of the bone defects; bioactive glasses (FillerBone and PerioGlas) allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; and the cavities filled with calcium phosphate cement (BoneSource) were generally filled by connective fibrous tissue, and the material was almost totally resorbed. Discussion: the autogenous bone, FillerBone, and PerioGlas provided results similar to those in the current literature, showing that autogenous bone is the best Choice for filling critical-size defects. Synthetic implanted materials demonstrated biocompatibility, but the bioglasses demonstrated osteoconductive activity that did not occur with calcium phosphate (BoneSource). Conclusion: According to the methodology used in this study, it can be concluded that the utilization of autogenous bone and bioactive glasses permitted the repair of surgically created critical-size defects by newly formed bone; the synthetic implanted materials demonstrated biocompatibility, and the bioactive glasses demonstrated osteoconductive activity. The PerioGlas was mostly resorbed and replaced by bone and the remaining granules were in close contact with bone; the FillerBone showed many granules in contact with the newly formed bone; BoneSource did not permit repair of the critical-size defects, and the defects were generally filled by connective fibrous tissue.
Resumo:
Objectives: To survey the current radiographic prescriptions in dental implant assessment amongst dentists in Brazil.Methods: Sixty-nine dentists were interviewed during a dental implant meeting by two calibrated graduate students, using a 19-question questionnaire, considering imaging modality options both for pre-operative implant site assessment and for follow-up, particularly with respect to cost, patient radiation dose, and broad coverage of facial bones and teeth. Epi-Info 6.04 software was used to analyse the database file.Results: Approximately 63.8% of the dentists prescribed only panoramic radiography for dental implant assessment and 28.9% ordered panoramic radiography plus periapical radiography and/or conventional tomography and/or computed tomography (CT). Only 7.2% of the dentists ordered conventional tomography or CT as a single examination, although 10.1% ordered it in combination with other imaging modalities. The main reasons given for prescribing panoramic radiography were broad coverage and cost (86.4%).Conclusions: This study has shown that most of the dentists in this study prescribe panoramic radiographs in dental implant assessment based on broad coverage and cost. They are not following the American Academy of Oral and Maxillofacial Radiology recommendations regarding cross-sectional imaging.
Resumo:
The present study compares the biologic behavior of BioGran and Calcitite as fillers for surgical cavities in the mandibles of 4 adult monkeys (Cebus apella). The surgical cavities were prepared through both mandibular cortices, with a diameter of 5 mm, in the angle region. Two cavities were prepared on the right side and 1 on the left and divided into 3 groups: R-1 sites were filled with bioglass (BioGran), R, sites were not filled, and L sites were filled with hydroxyapatite (Calcitite). After 180 days the animals were sacrificed and the specimens were removed for histologic processing. Results showed no bone formation in group R, (empty cavities). BioGran-treated sites showed bone formation and total repair of the bone defect, and the bioglass particles were almost totally resorbed and substituted by bone. The few remaining crystals were in intimate contact with newly formed bone. Calcitite did not allow bone formation, and granules inside the cavities were involved by connective tissue. Based upon those results, the authors concluded that bioglass resulted in total obliteration of the surgical cavity with bone and hydroxyapatite was present in a large amount and involved by connective tissue, without bone formation.
Resumo:
Missing maxillary lateral incisors create an esthetic problem with specific orthodontic and prosthetic considerations. Implants are commonly used to replace congenitally missing lateral incisors in adolescent orthodontic patients. However, an interdisciplinary approach should be observed during the diagnosis, prognosis, and treatment plan to provide a result with good predictability and meet the esthetic and functional expectations of the patient. The present study describes a case of a young patient with tooth agenesis of maxillary lateral incisors, which was conducted with an integrated planning. After 5-year follow-up of 2 fixed implant-supported prostheses, clinical and radiographic examination showed the treatment to be successful. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:e22-e28)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)