198 resultados para Electromyography fatigue threshold


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural component failures due to cyclic loading are associated to surface damage of materials and its interaction with environment. Fatigue failure occurs with stresses below the yield strength of each material and is a result of crack initiation and propagation. In aeronautical components is an important parameter to be considered in project, as well as the corrosion and wear resistance. Thermally sprayed HVOF coatings have been considered to replace galvanic chromium deposits with comparable performance for wear and corrosion resistance. The aim of present research is to study the influence of WC-13Co-4Cr applied by HVOF, on the axial fatigue strength of 15-5 PH stainless steel. The shot peening treatment was used to restore fatigue performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project was originated from the national aircraft industry requirements to reduce the use of coated materials with electroplated chromium or cadmium that produce waste, which is harmful to health or the environment. The selected material is a Custom 465 stainless steel used in the aeronautical field due to its high mechanical strength. Considering the load sustained by the wheel axis of the landing gear, the Custom 465 is tested in axial fatigue. The objective is to compare the behavior of the Custom 465 with plated AISI 4340 steel coated with cadmium. X-ray diffraction method was used to determine the residual stress field induced by shot peening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Removable partial dentures are affected by fatigue because of the cyclic mechanism of the masticatory system ansi frequent insertion and removal. Titanium and its alloys have been used in the manufacture of denture frameworks; however, preventive agents with fluorides are thought to attack titanium alloy surfaces.Purpose. This study evaluated, compared, analyzed the corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different storage environments.Material and methods. For each metal, 33 dumbbell rods, 2.3 mm in diameter at the central segment, were cast in the Rematitan system. Corrosion-fatigue strength test was carried out through a universal testing machine with a load 30% lon er than the 0.2% offset yield strength and a combined influence of different: environments: in air at room temperature, with synthetic saliva, and with fluoride synthetic saliva. After failure, the number of cycles were recorded, and fracture surfaces were examined with on SEM.Results. ANOVA and Tukey's multiple comparison rest indicated that Ti-6Al-4V alloy achieved 21,269 cycles (SD = 8,355) against 19,157 cycles (SD = 3,624) for the commercially purr Ti. There were no significant differences between either metal in the corrosion-fatigue life for dry specimens, but when the solutions were present, the fatigue life was significantly reduced, probably because of the product-ion of corrosion pits caused by superficial reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project was originated from the national aircraft industry requirements to reduce the use of coated materials with electroplated chromium or cadmium that produce waste, which is harmful to health or the environment. The selected material is a Custom 465 stainless steel used in the aeronautical field due to its high mechanical strength. Considering the load sustained by the wheel axis of the landing gear, the Custom 465 was tested in axial fatigue. The objective is to compare the behavior of the Custom 465 stainless steel with plated AISI 4340 steel coated with cadmium. Fractographic analysis was conducted using scanning electron microscopy. X-ray diffraction method was used to determine the residual stress field induced by shot peening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the validity of critical force test from maximal lactate steady state (MLSS) during resistance test using straight bench press. Five healthy male volunteers aged (22.6 ± 2.88 years), weight (76.3 ± 11.49 kg) e height (182.6 ± 7.54cm), trained in resistance exercise, and performed four diferent test to determine: one maximal effort (1RM), critical force using the critical power model (force vs 1/time limit - 20, 25 and 30% 1RM). The CF was the linear coefficient and the anaerobic impulse capacity (CIA) was the angular. MLSS was determined using loads of 80, 90, 100 and 110% of critical force. Blood lactate samples were abtained at each 300sec between each stage of total 1200sec. Maximal 30s test (M30) was accomplished with load of 25% of body weight in SBP. The results showed that the 1 RM was 79.4 Kgf (± 16.98), CF 10.1N (± 2.25), CIA 1756.82 N.s (± 546.96) and the R² 0.984 (± 0,02). The MLSS occurs at 100% CF load. The lactate concentration at the MLSS was 2.2 mmol/L (± 0.77). Significant correlation was observed between MLSS and CF on SBP (r = 0.88 p = 0.05). In M30 the minimum, mean and peak power were (25.0 ± 4.9, 28.0 ± 4.9, and 30.0 ± 4.6 kgf.rps, respectively). The fatigue index was 18.0% (± 6,8). The M30 was significantly correlated with Ppeak and Pmean (r = 0.98 for both, p = 0.003). The CF means has been validated to predict the resistance training and the CIA show to be a representative anaerobic parameter in straight bench press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power-counting arguments are used to organize the interactions contributing to the NN-->d pi,pn pi reactions near threshold. We estimate the contributions from the three formally leading mechanisms: the Weinberg-Tomozawa (WT) term, the impulse term, and the Delta-excitation mechanism. Subleading but potentially large mechanisms, including S-wave pion rescattering, the Galilean correction to the WT term, and short-ranged contributions are also examined. The WT term is shown to be numerically the largest, and the other contributions are found to approximately cancel. Similarly to the reaction pp-->pp pi(0), the computed cross sections are considerably smaller than the data. We discuss possible origins of this discrepancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze strength and integrated electromyography (IEMG) data in order to determine the neuromuscular efficiency (NME) of the vastus lateralis (VL) and biceps femoris (BF) muscles in patients with anterior cruciate ligament (ACL) injuries, during the preoperative and postoperative periods; and to compare the injured limb at these two times, using the non-operated limb as a control. EMG data and BF and VL strength data were collected during three maximum isometric contractions in knee flexion and extension movements. The assessment protocol was applied before the operation and two months after the operation, and the NME of the BF and VL muscles was obtained. There was no difference in the NME of the VL muscle from before to after the operation. On the other hand, the NME of the BF in the non-operated limb was found to have increased, two months after the surgery. The NME provides a good estimate of muscle function because it is directly related to muscle strength and capacity for activation. However, the results indicated that two months after the ACL reconstruction procedure, at the time when loading in the open kinetic chain within rehabilitation protocols is usually started, the neuromuscular efficiency of the VL and BF had still not been reestablished.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of recovery time after quadriceps muscle fatigue on gait in young adults. Forty young adults (20-40 years old) performed three 8-m gait trials at preferred velocity before and after muscle fatigue, and after 5, 10 and 20min of passive rest. In addition, at each time point, two maximal isometric voluntary contractions were preformed. Muscle fatigue was induced by repeated sit-to-stand transfers until task failure. Spatio-temporal, kinetic and muscle activity parameters, measured in the central stride of each trial, were analyzed. Data were compared between before and after the muscle fatigue protocol and after the recovery periods by one-way repeated measures ANOVA. The voluntary force was decreased after the fatigue protocol (p<0.001) and after 5, 10 and 20min of recovery compared to before the fatigue protocol. Step width (p<0.001) and RMS of biceps femoris (p<0.05) were increased immediately after the fatigue protocol and remained increased after the recovery periods. In addition, stride duration was decreased immediately after the fatigue protocol compared to before and to after 10 and 20min of rest (p<0.001). The anterior-posterior propulsive impulse was also decreased after the fatigue protocol (p<0.001) and remained low after 5, 10 and 20min of rest. We conclude that 20min is not enough to see full recovery of gait after exhaustive quadriceps muscle fatigue.