206 resultados para Cobalt pentacyanonitrosylferrate
Resumo:
Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Medical Physics is an interdisciplinary field that applies concepts and laws of physics in medical practices. Currently, one of its main applications is the use of ionizing radiation in the treatment of oncological diseases. Due to its wide use and highly dangerous, many of radioprotection procedures should be adopted with the objective of protecting human beings from harmful effects of radiation. Thus, you can better enjoy the benefits that the practice can offer. The methodology proposed by the National Council on Radiation Protection 151 (NCRP 151), relates technical information necessary to Structural Shielding Design and Evaluation for Megavoltage X- and Gamma- Ray Radiotherapy Facilities. However, many parameters used to calculate the shield are based on estimates only, and it is an international standard that may not be adequate to the Brazilian reality. Thus, the central idea of this study is the collection of data from the routine of the Radiotherapy Service of the Real e Benemérita Associação Portuguesa de Beneficência, in particular equipment cobalt therapy Theratron 780 (Atomic Energy of Canada Ltd.) and the linear accelerator Varian Clinac 2100C for measurement of workload, number of patients, fields, and dose factors to determine the best use of barrier protection. Furthermore, this work features a profile of radiotherapy treatments carried out closer to the Brazilian reality
Resumo:
Cobalt is a essential microelement for the metabolismo of ruminants. Its deficiency leads to decreased levels of vitamin B12 and, consequently, non propionic acid metabolism. Thus, there will be no gliconeogenes and animals have defict glucose, and other tramadol dosing as apathy, alitriofagia, and decrease in production. It is a disease that affects catthe, of economic importance in Brazil, wich is related to the of the soilcomposition
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Química - IQ
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)