187 resultados para ATOMIC ABSORPTION SPECTROMETRY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sample preparation method based on ultrasound assisted-extraction (UAE) of Ca, Mg and P from swine feed has been described. The experiment was performed to cover the variables influencing the sonication process and, the method validation using standard reference material. Final solutions obtained upon sonication were analyzed by flame atomic absorption spectrometry (for Ca and Mg) and by UV-vis spectrophotometry (for P). The best conditions for metal extraction were as follows: sample mass: 100 mg in 20 mL 0.10 mol/L HCl, a particle size: <60 μm, sonication time: 5 cycles of 10 s and ultrasound power: 102 W. The UAE method was applied in digestibility assays in different piglet feeds and their results showed that it is highly comparable (P > 0.05) to the other methods used for such purposes, as block digestion, and offered a Ca, Mg and P method of quantification limit of 10.6, 12.4 and 14 mg/kg, respectively. The major advantages of the UAE method compared to other methods are the high treatment rate, low reagent usage in the extracts and, it does not generate toxic residues that might negatively affect human health and the environment, accompanied by good precision and accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The following research project deals with the development of new analytical procedures aimed at the identification and quantification of the element zinc in different fractions of vegetable drugs used for weight loss, using the high-resolution continuum source atomic absorption spectrometry in flame. The determination of the levels of zinc was made in an AnalytikJena ContrAA 300 spectrometer in the principal line of Zn at 213.857 nm and wavelength integrated absorbance equal to 3 pixels. Calibration curves were obtained with linear dynamic range from 0.10 to 1.00 mg L-1, correlation coefficient equal to 0.9991 and limit of detection equal to 0.020 mg L-1. The total Zn content in the samples obtained after microwave-assisted acid digestion system were: 28.06 mg kg-1 (Artichoke), 31.49 mg kg-1 (Chamomile), 77.16 mg kg-1 (Gorse), 105.38 mg kg-1 (Horsetail), 32.37 mg kg-1 (Fennel) and 5.00 mg kg-1 (Senna). The extraction in aqueous environment assisted by microwave radiation produced extracts containing: 5.40 mg kg-1 (Artichoke), 10.65 mg kg-1 (Chamomile), 14.83 mg kg-1 (Gorse), 18.90 mg kg-1 (Horsetail), 7.80 mg kg-1 (Fennel), 3.24 mg kg-1 (Senna), corresponding to 19%, 34%, 19%, 18%, 24% and 64% of their total content of Zn, respectively. The amounts of Zn in the extracted samples from some plants indicate that this metal was strongly bounded to the plant's matrix. The sequential extraction using solvents and mixtures with different polarities (n-hexane, ethyl acetate, propanol, methanol, ethanol-water 1:1 (v/v), water) aimed the separation of different Zn containing species and water was considered the most efficient extractor. The Zn contents extracted were: 14.82 mg kg-1 (Artichoke), 16.82 mg kg-1 (Chamomile), 34.09 mg kg-1 (Gorse), 4.75 mg kg-1 (Senna), corresponding to 53% in the first two samples, 44% and 95% for the last two, respectively. It was observed that Zn is found complexed under

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)