232 resultados para 1055
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dioctadecyl-dimethyl-ammonium bromide (DODAB) vesicles can be characterized by their differential scanning calorimetry (DSC) thermograms comprised of two endotherms at T (s) a parts per thousand 36 A degrees C and T (m) a parts per thousand 45 A degrees C in the heating, ascribed respectively to the subgel-to-gel and gel-to-liquid crystalline transitions, and two exotherms at T'(m) a parts per thousand 40 A degrees C and T'(s) a parts per thousand 16 A degrees C in the cooling, ascribed respectively to the liquid crystalline-to-gel and gel-to-subgel transitions. It has been reported but not proved that the T (m)-transitions, the T'(m)-transitions, the T (s)-transitions, and the T'(s)-transitions are reverse to each other, displaying hystheresis Delta T (m) a parts per thousand 5 A degrees C and Delta T (s) a parts per thousand 20-25 A degrees C, respectively. By investigating the effects of the initial scanning temperature (T (i)) on the transition enthalpies (Delta H (m), Delta H (s), Delta H'(m) and Delta H'(s)), we have seen that these transitions are the reverse to each other and display different kinetics.
Resumo:
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of pantoprazole (CAS 102625-70-7) in human plasma using lansoprazole (CAS 103577-45-3) as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid/liquid extraction using diethyl-ether/dichloromethane (70:30; v/v) and chromatographed on a C-8 analytical column. The mobile phase consisted of acetonitrile/water/methanol (57:25:18; v/v/v) + 10 mmol/l acetic acid + 20 mmol/l ammonium acetate. The method has a chromatographic total run time of 4.5 min and was linear within the range 5.0-5,000 ng/mL. Detection was performed on a triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precisions calculated from quality control (QC) samples were 4.2% and 3.2%, respectively. The accuracies as determined from QC samples were -5.0% (intra-run) and 2.0% (inter-run). The method herein described was employed in a bioequivalence study of two tablet formulations of pantoprazole.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)