297 resultados para piñón


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we have studied pure and thulium- and chromium-doped ZBLAN glasses irradiated by ultra-short laser pulses. A Ti:sapphire CPA system was used, producing a 500 Hz train of pulses, centered at 830 nm, with 375 mu J of energy and 50 fs of duration (FWHM). The beam was focused by a 20 Him lens, producing a converging beam with a waist of 12 pin. The absorption spectra before and after laser irradiation were obtained showing production of color centers in pure, thulium-doped and chromium-doped ZBLAN glasses. A damage threshold of 9.56 TW/cm(2) was determined for ZBLAN. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the composition and antifungal activity against Cladosporium sphaerospermum and Cladosporium cladosporioides of essential oils of leaves of Piper cernuum, Piper diospyrifolium, Piper crassinervium, Piper solmsianum and Piper umbelata and fruits of P. cernuum and P. diospyrifolium. The essentials oils were analyzed by GC-MS and submitted of the antifungal activity tests. The essential oils of fruits from P. cernuum and leaves of P. crassinervium and P. solmsianum showed potential antifungal activity against C. sphaerospermum and C. cladosporioides. In addition, this is the first report of the composition of essential oils of fruits of P. cernuum and P. diospyrifolium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Existe uma demanda, na região semiárida produtora de uvas no Submédio São Francisco, por medidas sustentáveis de controle de doenças pós-colheita, uma vez que o modelo atual de revestimento de caixas com polietileno de alta densidade, associado ao metabissulfito de sódio, não tem se mostrado eficiente no controle dos fungos que ocorrem na região. O objetivo desse trabalho foi estudar um controle da podridão por Aspergillus em uvas 'Thompson Seedless' por meio da modificação da atmosfera, pelo envolvimento de caixas de uva em bolsões de poliamida. Comparou-se o bolsão de poliamida (PA) ao de polietileno alta densidade (PEAD), comumente usado na região, combinados ou não com o metabissulfito de sódio (SO2). Frutos provenientes de propriedade comercial, após serem selecionados e desinfestados foram feridos com alfinete entomológico e inoculados com uma suspensão de Aspergillus niger na concentração de 10(6) conídios.mL-¹ e submetidos à câmara úmida por 24 horas. em seguida as caixas de uva foram colocadas em bolsões específicos de acordo com o tratamento e armazenadas em câmara fria à temperatura de 2 ºC e umidade relativa de 75%, durante 40 dias. A partir do 12º dia de armazenagem foram feitas avaliações semanais da incidência da doença e de variáveis físico-químicas: perda de massa, sólidos solúveis totais (SST), pH, acidez titulável (AT), ratio (SST/AT); peroxidase (POD) e medição das concentrações de CO2 e O2 até o 40º dia. O delineamento experimental utilizado foi inteiramente ao acaso em parcelas subdivididas com cinco repetições. O revestimento de caixas de uva em bolsões de poliamida, mesmo sem o uso de metabissulfito de sódio, apresenta-se como uma alternativa viável na manutenção da qualidade pós-colheita de uva Thompson Seddless, bem como na redução de podridão causada por A. Niger. A enzima peroxidase pode ter atuado no processo de manutenção de qualidade da fruta, contribuindo para uma redução dos níveis da doença em uvas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cultura in vitro é uma técnica controlada que proporciona estudar os processos nutricionais, fisiológicos e bioquímicos de embriões em vários estádios de desenvolvimento. O objetivo foi avaliar a relação entre estádio de desenvolvimento do fruto e concentração de sacarose, no meio, durante o desenvolvimento, in vitro, de embriões de cafeeiro. Frutos de Coffea arabica cv. Acaiá foram colhidos, lavados, desinfestados, seus embriões excisados e inoculados em meio de cultivo MS, com pH ajustado para 5,8. Os tratamentos consistiram em combinação de concentrações de sacarose (0, 15, 30, 60, 90 e 120 g L-1) e estádios de desenvolvimento do fruto (chumbinho, chumbo, verde, verde-cana, cereja e passa). Após a inoculação, os embriões foram incubados em sala de crescimento, a 27 ± 1 ºC, fotoperíodo de 16 horas e 35 µ mol m-2 s-1 de intensidade luminosa. O delineamento experimental utilizado foi inteiramente casualizado, em esquema fatorial 6 x 6, com seis repetições constituídas por quatro tubos cada. Após 60 dias de desenvolvimento, as plântulas foram avaliadas com base no comprimento da parte aérea, massa de matéria fresca total da parte aérea e das raízes. Observaram-se influências das concentrações de sacarose e dos estádios de desenvolvimento do fruto no crescimento e desenvolvimento das plântulas. Resultados satisfatórios para todas as variáveis estudadas foram obtidos com embriões excisados no estádio verde, inoculados em meio de cultivo suplementado com 51 a 70 g L-1 de sacarose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A técnica TightRope, que procura aperfeiçoar a estabilização extra-capsular com sutura lateral, por meio da realização de mínimas incisões e criação de túneis ósseos em pontos isométricos, que permitem a inserção de mecanismo que anula o movimento de gaveta, além de reduzir a ocorrência de complicações graves. Dessa forma, objetivou-se avaliar a modificação da técnica TightRope em joelhos de cadáveres caninos com a finalidade de disponibilizar um procedimento simples e de custo reduzido para tratamento da Ruptura do ligamento cruzado cranial (RLCCr). Experimentalmente, foram utilizados 20 membros pélvicos de dez cadáveres caninos, provenientes do setor de patologia da Universidade Norte do Paraná, os quais pesavam entre 6,3 e 24kg. Para estabilização do LCCr, rompido intencionalmente, foi adotada a técnica de TightRope modificada utilizando fio de poliamida, cavilha e emprego de um parafuso ortopédico para proporcionar a fixação óssea. Comparando os valores de deslocamento obtidos durante a realização do movimento de gaveta previamente à ruptura do LCCr e após a realização do procedimento cirúrgico, observou-se que a modificação da técnica TightRope promoveu estabilidade significativa para a maioria (12 de 20) dos joelhos testados (P=0,0033). Contudo, essa estabilidade foi inferior, quando comparada à estabilidade do ligamento intacto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

1/N(c) expansion in QCD (with N(c) the number of colors) suggests using a potential from meson sector (e.g., Richardson) for baryons. For light quarks a sigma-field has to be introduced to ensure chiral symmetry breaking (chi-SB). It is found that nuclear matter properties can be used to pin down the chi-SB modeling. All masses, M(N), m-sigma, m-omega, are found to scale with density. The equations are solved self-consistently.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanocomposites created with polycarboxylic acid alone as a stabilization agent for prenucleation clusters-derived amorphous calcium phosphate exhibit nonperiodic apatite deposition. In the present study, we report the use of inorganic polyphosphate as a biomimetic analog of matrix phosphoprotein for directing poly(acrylic acid)-stabilized amorphous nano-precursor phases to assemble into periodic apatite-collagen nanocomposites. The sorption and desorption characteristics of sodium tripolyphosphate to type I collagen were examined. Periodic nanocomposite assembly with collagen as a template was demonstrated with TEM and SEM using a Portland cement-based resin composite and a phosphate-containing simulated body fluid. Apatite was detected within the collagen at 24 h and became more distinct at 48 h, with prenucleation clusters attaching to the collagen fibril surface during the initial infiltration stage. Apatite-collagen nanocomposites at 72 h were heavily mineralized with periodically arranged intrafibrillar apatite platelets. Defect-containing nanocomposites caused by desorption of TPP from collagen fibrils were observed in regions lacking the inorganic phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the effect of different microwave curing cycles on the changes in occlusal vertical dimension of complete dentures. Four test groups with 12 maxillary dentures each were evaluated. Groups 1, 2 and 3 were polymerized with different cycles by microwave radiation and Group 4 was the control and cured by water bath. The average pin opening for all groups was less than 0.5 mm. There was no significant difference between the groups polymerized by the microwave method and the control group. However, analyses of the vertical dimension changes showed statistically significant differences between groups 2 (0.276 +/- 0.141 mm) and 3 (0.496 +/- 0.220 mm).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aluminum matrix composites are currently considered as promising materials for tribological applications in the automotive, aircraft and aerospace industries due to their great advantage of a high strength-to-weight ratio. A superior combination of surface and bulk mechanical properties can be attained if these composites are processed as functionally graded materials (FGM's). In this work, homogeneous aluminum based matrix composite, cast by gravity, and aluminum composites with functionally graded properties, obtained by centrifugal cast, are tested against nodular cast iron in a pin-on-disc tribometer. Three different volume fractions of SiC reinforcing particles in each FGM were considered in order to evaluate their friction and wear properties. The sliding experiments were conducted without lubrication, at room temperature, under a normal load of 5 N and constant sliding speed of 0.5 ms-1. The worn surfaces as well as the wear debris were characterized by SEM/EDS and by atomic force microscopy (AFM). The friction coefficient revealed a slightly decrease (from 0.60 to 0.50) when FGM's are involved in the contact instead of the homogeneous composite. Relatively low values of the wear coefficient were obtained for functionally graded aluminum matrix composites (≈10-6 mm3N-1 m-1), which exhibited superior wear resistance than the homogeneous composite and the opposing cast iron surface. Characterization of worn surfaces indicated that the combined effect of reinforcing particles as load bearing elements and the formation of protective adherent iron-rich tribolayers has a decisive role on the friction and wear properties of aluminum matrix composites.