178 resultados para adhesives


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study evaluated the durability of bond strength to enamel using total-etch (Single Bond/SB) and self-etch (Clearfil SE Bond/CSEB) adhesives associated with neody-mium: yttrium-aluminu- garnet (Nd:YAG) laser irradiation through the uncured adhesives.Methods: Bovine incisors were worn to expose an area of enamel and were divided into four groups: group 1 (control) SB + polymerization; group 2 (control) CSEB + polymerization; group 3 (laser) - B + Nd:YAG laser (174.16 J/cm(2)) + polymerization; and group 4 (laser) CSEB + Nd:YAG (174.16 J/cm(2)) + polymerization. Blocks of composite were fabricated and stored for 24 hours or 12 months, sectioned into beams, and submitted to microtensile tests. Results were analyzed by three-way analysis of variance (ANOVA) (adhesive, technique, and storage time) and Tukey tests.Results: ANOVA revealed significant differences for adhesive 3 technique and technique 3 storage time (p<0.05). The mean values (MPa) for interaction adhesive x technique (standard deviation) were as follows: SB/control = 35.78 (6.04)a; SB/laser = 26.40 (7.25)b, CSEB/control = 26.32 (5.71)b, CSEB/laser = 23.90 (7.49)b. For interaction technique x storage time the mean values were as follows: control/24 hours = 32.58 (6.49)a; control/12 months = 29.52 (8.38)a; laser/24 hours = 29.37 (5.71)a; laser/12 months = 20.92 (6.5)b. Groups with the same letters showed no statistically significant differences.Conclusion: Scanning electron microscope analysis showed evident areas of micromorphological alterations in lased samples after 12 months of water storage. Nd: YAG laser irradiation of enamel through unpolymerized totaletch adhesive significantly reduced bond strength compared with the control. Bond strength decreased when enamel samples irradiated with Nd: YAG laser through unpolymerized adhesives were stored in water for 12 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study investigated the repairs of resin composite restorations after using different surface treatments.Design: Eighty four truncated cones of Filtek Z350 were prepared and thermo-cycled (20,000 cycles). Surfaces were roughened with diamond bur and etched with 37% phosphoric acid. Those cones were divided into 7 groups (N=12): 1) Prime&Bond 2.1; 2) aluminum oxide sandblasting+Prime&Bond 2.1; 3) Er:YAG laser treatment+Prime&Bond 2.1; 4) 9.6% hydrofluoric acid for 2 min-Fsilane coupling agent.; 5) silane coupling agent; 6) auto-polymerized acrylic monomer+Prime&Bond 2.1; 7) Adper Scothbond SE. Teflon device was used to fabricate inverted truncated cones of repair composite over the surface-treated. The bonded specimens were stressed to failure under tension. The data were analyzed with oneway ANOVA and Tukey tests.Results: Mean repair strengths (SD, in MPa) were, Group-2: 18.8a; Group-1: 18.7a; Group-6: 13.4ab; Group-7: 9.5bc; Group-3: 7.5bcd; Group-4: 5.2cd; Group-5: 2.6d.Conclusions: The use of diamond bur and a conventional adhesive and the use of aluminum oxide sandblasting prior to adhesive provided a simple and cost-effective solutions to composite repair. Er:YAG laser, silane alone, 9.6% hydrofluoric acid plus silane or a self-etching adhesive results in inferior composite repair strengths. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Evaluate the impact of the use of strip adhesive over the quality of life of institutionalized patients and wearers of complete dentures. Material and method: Twenty-nine institutionalized patients wearers of complete denture were selected to this study and after a clinical exam, a questionnaire (adjusted and based upon the index of Oral Health Impact Profile and Oral Health-Related Quality of Life, OHIP and OHQOL) was applied to evaluate issues related to epidemiological conditions (gender and age), quality of life (pain, discomfort, functional limitations, phonetic, social, psychological and esthetic), taste and notion of implant treatment. Following this part, the patients received instruction to use the strips adhesives (Corega Fita Adesiva, Glaxo-Smith-Kline, Rio de Janeiro, Brazil), considering three in maxillary prosthesis and two in the lower prosthesis during a period of 30 days. After this period, all the patients were recall and the questionnaire was reapplied; add some adhesive performance questions, to compare the results before and after the adhesive use in terms of percentage. Result: After the adhesive strips use there were improvement of the functional, social and physcological limitation aspects, but without percentual increasement of phonetic and esthetics aspects. The results showed 65.5% of the answers stating adhesive maintenance between 6-12 hours, easy removal (68.9%), and without change the taste (89.6%). The notion for implant treatment was decreased changing from 75.8 to 37.9% after the adhesive use. Conclusion: The results enhanced a positive impact over quality of life of the respondents after the strip adhesive use, showing decrease of pain and discomfort, mainly of inferior dental prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the decades, there was an evolution in dentistry, specifically in filling technique, and Buonocore (1955) has been the introducer of Adhesive Era. Thus, this paper aims to review the literature about the current adhesive systems. Was performed a literature review about the 5th and 6th adhesive system generations. The titles and abstracts of published articles were analyzed in PubMed database over the past 5 years. However, there are still different views about the technique used, therefore, because the diversity of these materials, it is impossible to highlight one that presents the best efficiency in all situations, being the responsibility of the professional the knowledge of the techniques and clinical applicability of each material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine physical properties of particleboard made of sawmill waste, as a mix of several wood species, and two adhesives: urea-formaldehyde, usually employed in industry (even with drawbacks or formaldehyde emission during pressing) and FASTBOND®, water based resin, still poorly referenced in literature. Sixteen panels have been produced, in four experimental conditions, defined by using two adhesives and a 12 mm thick limiter (or not). Variance analysis was adopted to evaluate influence of experimental conditions on physical properties of produced panels, manufactured in nominal dimensions 350x350mm; 10% resin related to particles mass (at 5% moisture); 3.5 MPa compaction pressure, temperature 130°C, in a 10 min cycle. Tests to determine density, moisture content, swelling and water absorption were carried out based on normative parameters of ABNT NBR 14810:2006. Results have been satisfactory to panels produced with urea-formaldehyde but those manufactured with polychloroprene based resin (FASTBOND®) not meet regulatory requirements. Best results have been obtained without limiter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current concern with the environment promotes the development of new technologies for production with use of alternative materials, from renewable resources, and changes in production processes, having as main objective the reduction of environmental impact. One of the alternatives for cleaner production is the use of castor oil derivatives instead of non-renewable sources, such as adhesives based on PVA (polyvinyl acetate), applied in the manufacturing process of glued laminated bamboo. Based on the versatility of the bamboo laminate and the castor oil, and from the perspective of sustainability, this study aims to contribute to the application of new materials and processes, used in the manufacturing industry, by proposing the use of the polyurethane adhesive based on castor oil for glued laminated bamboo manufacturing, which can later be used in the manufacture of several products. To verify the applicability of the polyurethane adhesive based on castor oil in the glued laminated bamboo manufacture, mechanical tests of traction and shearing of the glue sheet were performed in specimens of the said material, and the results were compared with the Cascorez 2590 and Waterbond adhesives. The results showed that the polyurethane adhesive based on castor oil, in the traction test, has superior performance than the Waterbond adhesive and slightly below than the Cascorez 2590 adhesive, but in the shear test, the polyurethane adhesive based on castor oil presented a slightly inferior performance than the other two adhesives used in the comparison.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze the behavior of the flow of heat (temperature) through the thickness of panels LVL (Laminated veneer lumber) produced with phenol formaldehyde adhesive, in laboratorial and industrial scales. Experimental program was conducted with five LVL panels (three produced in laboratorial scale and two in industrial scale) with different arrangements of a mix of commercial veneers from tropical pinus from the south region of Sao Paulo State, Brazil, bonded using phenol formaldehyde adhesive. The temperature inside the panels during the pressing process was evaluated using thermocouples type T (cooper-constantan), installed mostly in the center of the glue lines and connected to a data acquisition system. The graphics of temperature as a function of the time showed a gradual increase of temperature up to pre-set values, remaining constant from them. The temperature reached at the center of the panels was adequate to promote the curing of the adhesive. These pre-set values were similar to the minimum values presented by other authors and manufacturers of these adhesives that affirm that temperatures above 100ºC at the center of laminated panels bonded with phenolic adhesives are sufficient to ensure proper cure of the resin. The time necessary for curing of the adhesives confirmed the validity of practical expressions provided by adhesive manufacturers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)