331 resultados para Transtibial prostheses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Calcium phosphate-based bioactive ceramics in various physical and chemical formulations have been extensively utilized as biomaterials for bone regeneration/conduction. However, the determination of their in vivo temporal behavior from the short to long term in humans has been a challenge due to the lack of physical reference for morphologic and morphometric evaluation. The present study evaluated bone morphology and morphometry (bone-to-implant contact [BIC]) around plasma-sprayed hydroxyapatite (PSHA)-coated endosseous implants that were retrieved due to prosthetic reasons while successfully in function at the posterior region of the jaws from as early as 2 months to ~13 years after a 6-month healing period after placement. Bone morphology was evaluated by light microscopy, and BIC was determined using computer software. Irrespective of the time in vivo, lamellar bone was observed in close contact with the implant PSHA-coated surface and between plateaus. BIC ranged from ~35-95%, was highly directional, and Haversian-like osteonic morphology between plateaus was observed for most implants. The PSHA coating was present with little variation in thickness between the samples retrieved regardless of time in vivo. © 2010 by Begell House, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To assess the number of occlusal contacts achieved in temporal prostheses mounted in a semi-adjusted articulator using the facial arch and the Camper plane. Ten patients treated in a private clinic were selected to be rehabilitated with prostheses in previously placed single implants. For each patient two temporal prostheses were designed obtained under different conditions: (1) model mounting using facial arch and (2) Camper plane mounting. Prostheses were made and adjusted in the laboratory and placed only by an operator. The occlusal contacts achieved in each condition were photographed being assessed and quantified by a second professional not involved with the mounting conditions. Results obtained were analyzed by Mann-Whitney test with a 5 % significance level. There was not a statistically difference between the number of occlusal contacts when prostheses were made with facial arch or Camper plane (p= 0.113). The temporal dental prosthesis confection for single implants, semi-adjusted articulator using the Camper plane, not differ very much from the facial arch use, according to the number of resulting occlusal contacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Colour stability of resin and silicone is an important factor for longevity of facial prostheses. The aim of this study was to evaluate the colour stability of resins and silicone for facial prostheses. Three brands of acrylic resin and one of facial silicone were evaluated considering pigment incorporation for the colourless materials. Ten samples of each material were fabricated and submitted to measurements of chromatic alteration initially and after 90 and 180 days of weathering natural through visual analysis and spectrophotometry. Data were evaluated by ANOVA and Tukey test (p < 0.05). Statistically significant colour alteration was observed among some materials regardless of the period. The materials did not present a statistical difference between 90 and 180 days except for the pigmented heat-polymerized resin. The colour difference between pigmented Silastic MDX4-4210 and colourless Silastic was statistically significant (p < 0.01) in both periods as well as between pigmented and colourless heat-polymerized resin, and between the resins Rapidaflex and Lentaflex. The visual method demonstrated colour alteration in all materials evaluated during the first 90 days of ageing. All materials exhibited colour alteration due to exposure to environment. © 2012 Informa UK, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with congenital malformations, traumatic or pathological mutilation and maxillofacial developmental disorders can be restored aesthetically and emotionally by the production and use of facial prostheses. The aim of this study was to review the literature about the retention and processing methods of facial prostheses, and discuss their characteristics. A literature review on Medline (PubMed) database was performed by using the keywords maxillofacial prosthesis, silicone, resin, pigment, cosmetic, prosthetic nose, based on articles published from 1956 to 2010. Several methods of retention, from adhesives to the placement of implants, and different processing methods such as laser, CAD/CAM and rapid prototyping technologies have been reported. There are advantages and disadvantages of each procedure, and none can be classified as better compared to others.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shellac is a natural resin used for the preservation of fruits, bones and as a coating on drugs. The hydroxyapatite (HA), which is naturally found in human bones, is used as filler to substitute amputated bone or as a coating for prosthetics, promoting bone growth in implants of prostheses. The objective of this work is to immobilize HA from an alcoholic solution of shellac on plates of titanium, niobium and AISI 316L steel using the simple dip-coating method. The corrosion resistance of the uncoated films is compared with ones coated with shellac and shellac plus HA. The deterioration of the film composed of shellac with hydroxyapatite in saline solution follows the ascending order: AISI 316L steel, titanium, niobium. The elemental analysis of the shellac showed that it mainly consists of the elements C, H, N and O. We used the FT-IR spectrum to characterize the shellac and HA. ©The Electrochemical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the effect of an Argon-based nonthermal plasma (NTP) surface treatment-operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: Calcium-Phosphate (CaP) and CaP + NTP (CaP-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received 2 plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ca, C, O, and P for the CaP and CaP-Plasma surfaces. Both surfaces presented carbon primarily as hydro-carbon (CAC, CAH) with lower levels of oxidized carbon forms. The CaP surface presented atomic percent values of 38, 42, 11, and 7 for C, O, Ca, and P, respectively, and the CaPPlasma presented increases in O, Ca, and P atomic percent levels at 53, 12, and 13, respectively, in addition to a decrease in C content at 18 atomic percent. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC and BAFO were observed for CaPPlasma treated surfaces. Surface elemental chemistry was modified by the Ar-based NTP. Ar-based NTP improved bone formation around plateau-root form implants at 3 weeks compared with CaP treatment alone. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the improvement in psychosocial awareness of anophthalmic patients wearing ocular prostheses and its relationship with demographic characteristics, factors of loss/treatment, social activity, and relationship between professional and patient. Surveys including a form for evaluation of psychosocial pattern were conducted with 40 anophthalmic patients rehabilitated with ocular prosthesis at the Center of Oral Oncology in the authors' dental school from January 1998 to November 2010. The improvement in psychosocial awareness was assessed by comparing the perception of some feelings reported in the period of eye loss and currently. Wilcoxon tests were applied for comparison of patients' perception between the periods. χ2 tests were used to assess the relationship between the improvement in psychosocial awareness and the variables of the study. In addition, the logistic regression model measured this relationship with the measure of odds ratio. The feelings of shame, shyness, preoccupation with hiding it, sadness, insecurity and fear were significant for improvement in psychosocial awareness. It was concluded that the anophthalmic patients wearing an ocular prosthesis has significant improvement in psychosocial awareness after rehabilitation. © 2012 International Association of Oral and Maxillofacial Surgeons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). Materials and methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed™ TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. Conclusions: Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Ocular prosthesis materials should have specific properties for their indication and durability; therefore, it is important to investigate their physical behaviour when affected by several disinfectants. Objectives: This study evaluated the influence of different disinfecting solutions on the microhardness and surface roughness of acrylic resins for ocular prosthesis. Materials and Methods: Fifty samples simulating ocular prostheses were fabricated with N1 resin and colourless resin and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite (HYC) and 4% chlorhexidine (CHX). Samples were stored in saline solution at 37°C and disinfected during 120 days. Both microhardness and roughness were investigated before, after 60 days and 120 days of disinfection and storage. Microhardness was measured using a microhardner and the roughness with a roughness device. Results: N1 resin showed lower microhardness when compared with colourless resin (p < 0.05). HYC and CHX groups exhibited the highest change of microhardness and roughness values (p < 0.05). An increase in roughness and reduction in microhardness of ocular acrylic resins were observed after both periods of disinfection and storage (p < 0.05). Conclusion: Both disinfection/storage periods affected the microhardness and roughness values of the samples. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the compressive strength of microhybrid (Filtek™ Z250) and nanofilled (Filtek™ Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm -2 when using the fiber optic light tip and 596 mW cm-2 with the polymer. After storage in distilled water at 37 ± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min-1. The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane's test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth. © 2013 Astro Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to assess the shear bond strength between a heat-polymerized denture base resin and acrylic resin teeth after immersion in different denture cleansers by simulating a 180-day use. Two acrylic teeth (Biotone, Biotone IPN, Dentsply Ind. e Com., Rio de Janeiro, RJ, Brazil) were chosen for bonding to a heat-polymerized denture base resin (Lucitone 550- Dentsply Ind. e Com., Rio de Janeiro, RJ, Brazil). Eighty specimens were produced and divided into eight groups (n=10) according to their experimental condition (distilled water, 2% chlorhexidine digluconate, 1% sodium hypochlorite and Corega Tabs). Shear bond strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed by two-way analysis of variance (ANOVA) and Student-Newman-Keuls' multiple comparisons post hoc analysis (α=.05). The shear bond strength results revealed statistically significant differences between the groups. For the Biotone IPN tooth, significantly lower shear bond strength values were found for the group immersed in sodium-perborate solution (4.48±2.18 MPa) than for the group immersed in distilled water (control group) (10.83±1.84 MPa). For Biotone, significantly higher bond strength values (10.04±3.28 MPa) were found for the group immersed in Corega Tabs than for the control group (5.45±2.93 MPa). The immersion in denture cleanser solutions was more detrimental to the conventional acrylic denture tooth (Biotone) than to the highly cross-linked denture tooth (Biotone IPN). However, this effect was not observed for the groups immersed in Corega Tabs solution, regardless of the type of denture tooth. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.