248 resultados para Saddle fixed points


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lagrangian points L4 and L5 lie at 60 degrees ahead of and behind Moon in its orbit with respect to the Earth. Each one of them is a third point of an equilateral triangle with the base of the line defined by those two bodies. These Lagrangian points are stable for the Earth-Moon mass ratio. Because of their distance electromagnetic radiations from the Earth arrive on them substantially attenuated. As so, these Lagrangian points represent remarkable positions to host astronomical observatories. However, this same distance characteristic may be a challenge for periodic servicing mission. In this work, we introduce a new low-cost orbital transfer strategy that opportunistically combine chaotic and swing-by transfers to get a very efficient strategy that can be used for servicing mission on astronomical mission placed on Lagrangian points L4 or L5. This strategy is not only efficient with respect to thrust requirement, but also its time transfer is comparable to others known transfer techniques based on time optimization. Copyright ©2010 by the International Astronautical Federation. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semen cryopreservation is still considered suboptimal due to lower fertility when compared to fresh semen. The reasons for the loss of fertility are various and related to irreversible damage caused to the cells during the freeze-thaw process. An alternative to conventional cryopreservation represents the use of chilled bull semen, preventing the damage associated with freezing, thereby guaranteeing greater sperm viability. The aim of this study was to describe the use of cooled bull semen as a strategy to increase the pregnancy for Fixed-Time Artificial Insemination (FTAI) of Nellore (Bos indicus) cows. One ejaculate of a select Nellore bull obtained by electroejaculation was used; the semen sample was fractioned into two aliquots: one diluted in Botu-Bov® extender containing 6.4% glycerol for cryopreservation (BB-F, frozen group) and one diluted in the same extender, free from cryoprotectants and used for cooling (BB-C, cooled semen group). The samples in the BB-C group were chilled to 5°C using an isothermic box and maintained for 24 h prior to use. A total of 349 lactating Nellore cows (70-90 days after birth) were synchronized by the insertion of a progesterone releasing device (1.0 g) and estradiol benzoate (2.0 mg i.m.) on a random day of the estrous cycle (Day 0); FTAI was performed 44-48 h after the removal of the device. The pregnancy rates were 45.71 and 61.49% (P<0.05), respectively, for the cryopreserved or chilled bovine semen groups. In conclusion, the use of bull semen cooled for 24 h represents an alternative to conventionally cryopreserved semen, as determined by the increase the pregnancy per artificial insemination in bovine herds. © 2012 Science Publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the safety and efficacy of transitioning patients whose intraocular pressure (IOP) had been insufficiently controlled on prostaglandin analog (PGA) monotherapy to treatment with travoprost 0.004%/timolol 0.5% fixed combination with benzalkonium chloride (TTFC). Methods: This prospective, multicenter, open-label, historical controlled, single-arm study transitioned patients who had primary open-angle glaucoma, pigment dispersion glaucoma, or ocular hypertension and who required further IOP reduction from PGA monotherapy to oncedaily treatment with TTFC for 12 weeks. IOP and safety (adverse events, corrected distance visual acuity, and slit-lamp biomicroscopy) were assessed at baseline, week 4, and week 12. A solicited ocular symptom survey was administered at baseline and at week 12. Patients and investigators reported their medication preference at week 12. Results: Of 65 patients enrolled, 43 had received prior travoprost therapy and 22 had received prior nontravoprost therapy (n = 18, bimatoprost; n = 4, latanoprost). In the total population, mean IOP was significantly reduced from baseline (P = 0.000009), showing a 16.8% reduction after 12 weeks of TTFC therapy. In the study subgroups, mean IOP was significantly reduced from baseline to week 12 (P = 0.0001) in the prior travoprost cohort (19.0% reduction) and in the prior nontravoprost cohort (13.1% reduction). Seven mild, ocular, treatment-related adverse events were reported. Of the ten ocular symptom questions, eight had numerically lower percentages with TTFC compared with prior PGA monotherapy and two had numerically higher percentages with TTFC (dry eye symptoms and ocular stinging/burning). At week 12, TTFC was preferred over prior therapy for 84.2% of patients (48 of 57) by the patients themselves, and for 94.7% of patients (54 of 57) by their physicians. Conclusion: When TTFC replaced PGA monotherapy in patients whose IOP had been uncontrolled, the outcome was a significant reduction in IOP and an acceptable safety and tolerability profile. Most patients and investigators preferred TTFC to prior PGA monotherapy. © 2012 Costa et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative transfer strategy to send spacecrafts to stable orbits around the Lagrangian equilibrium points L4 and L5 based in trajectories derived from the periodic orbits around LI is presented in this work. The trajectories derived, called Trajectories G, are described and studied in terms of the initial generation requirements and their energy variations relative to the Earth through the passage by the lunar sphere of influence. Missions for insertion of spacecrafts in elliptic orbits around L4 and L5 are analysed considering the Restricted Three-Body Problem Earth- Moon-particle and the results are discussed starting from the thrust, time of flight and energy variation relative to the Earth. Copyright© (2012) by the International Astronautical Federation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives were to assess incidence of pregnancy losses, associate this outcome with immunization programs against reproductive diseases, and evaluate the effects of vaccination against bovine herpesvirus-1 (BoHV-1), bovine viral diarrhea virus (BVDV), and Leptospira spp., on reproductive efficiency of Brazilian cow-calf operations. In experiment 1, 7614 lactating Nelore cows from 18 ranches were assigned to the same estrus synchronization and fixed-time AI protocol (ESFTAI; Days -11 to 0). Pregnancy status was determined with transrectal ultrasonography on Days 30 and 120 after AI. Pregnancy loss was deemed to have occurred when cows were pregnant on Day 30 but nonpregnant on Day 120. Incidence of pregnancy loss across all ranches was 4.1%; pregnancy losses were detected (P < 0.10) in 14 ranches but not detected (P > 0.11) in four ranches. Pregnancy loss was lower (P ≤ 0.02) in ranches that vaccinated against BoHV-1, BVDV, and Leptospira spp. compared with ranches that did not vaccinate, or only vaccinated against Leptospira spp. In experiments 2 and 3, lactating Nelore cows (N = 1950 and 2793, respectively) from ranches that did not have a history of vaccinating against reproductive diseases (experiment 2), or only vaccinated against Leptospira spp. (experiment 3), were assigned to the same ESFTAI used in experiment 1. Within each ranch, cows received (VAC) or not (CON) vaccination against BoHV-1, BVDV, and Leptospira spp. at the beginning of the ESFTAI (Day -11) and 30 days after (Day 41) AI. In experiment 2, VAC cows had greater (P ≤ 0.05) pregnancy rates compared with CON on Days 30 and 120. In experiments 2 and 3, pregnancy loss was reduced (P ≤ 0.03) in primiparous VAC cows compared with CON cohorts. In experiment 4, 367 primiparous, lactating Nelore cows previously vaccinated against Leptospira spp. were assigned to the same ESFTAI used in experiment 1. Cows received VAC, or the same vaccine 30 days before (Day -41) and at the beginning (Day -11) of the ESFTAI (PREVAC). Pregnancy rates on Days 30 and 120 were greater (P ≤ 0.05) in PREVAC cows compared with VAC cows. In conclusion, pregnancy losses affected reproductive and overall efficiency of Brazilian cow-calf operations, and might be directly associated with BoHV-1, BVDV, and Leptospira spp. infections. Hence, vaccinating cows against these pathogens, particularly when both doses are administered before fixed-time AI, improved reproductive performance in Brazilian cow-calf systems. © 2013 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is known that several factors can affect the clinical success and durability of fixed partial dentures. Therefore, the aim of the present study was to present a literature review about the longevity, clinical success, and quality, as well as, patients' and dental surgeons' satisfaction of ceramic fixed dentures. High rate of patients' satisfaction has been observed in relation to the esthetic of ceramic crowns. In addition, the literature has shown that dental ceramics can be used in several clinical situations with high success rate and longevity. Despite of failures and complications of ceramic restorations, nowadays, with the improvement of mechanical properties of such materials, ceramic crowns present a favorable prognosis and can be used in several clinical situations with high success rate, clinical quality, and great patients' satisfaction. © 2013 The American Ceramic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Session ratings of perceived exertion (SRPE) have been considered to provide a quantitative evaluation of the entire exercise session in different types of resistance training. In this study we investigated the ability of SRPE to assess exercise strain in a circuit weight training (CWT) workout and the influence of time lag to report SRPE. Ten healthy male volunteers (22.3±2.8 years, 72.5±6.5kg, and 175±5cm) completed a CWT session involving three circuits of five multiple joint exercises with single sets of 20 repetitions at 30% one repetition maximum (1-RM). Heart rate [63.7-75.0% maximum heart rate (%HRmax)], blood lactate (5.6-7.6mM) as well as overall, chest, and active muscle RPE increased significantly (p<0.05) throughout the CWT, but no significant differences were found between ratings of perceived exertion (RPE) types. Overall, chest and active muscle SRPE were accessed 10 minutes, 20 minutes, and 30 minutes after the workout, with no significant main effects or SRPE type×time interaction being found (p>0.05). Finally, no significant differences (p>0.05) were observed between averaged SRPE and RPE responses (overall: 3.7±0.6 vs. 3.5±0.9; chest: 3.8±0.7 vs. 3.6±0.8; active muscle; 3.7±0.7 vs. 3.5±0.7). These results suggest SRPE, irrespective of the moment at which it is taken, to be a useful tool for assessing global exercise strain in a CWT workout, providing coaches, physicians, and exercisers a practical way for monitoring this type of resistance training. © 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Birth weight (BW) is an economically important trait in beef cattle, and is associated with growth- and stature-related traits and calving difficulty. One region of the cattle genome, located on Bos primigenius taurus chromosome 14 (BTA14), has been previously shown to be associated with stature by multiple independent studies, and contains orthologous genes affecting human height. A genome-wide association study (GWAS) for BW in Brazilian Nellore cattle (Bos primigenius indicus) was performed using estimated breeding values (EBVs) of 654 progeny-tested bulls genotyped for over 777,000 single nucleotide polymorphisms (SNPs).Results: The most significant SNP (rs133012258, PGC = 1.34 × 10-9), located at BTA14:25376827, explained 4.62% of the variance in BW EBVs. The surrounding 1 Mb region presented high identity with human, pig and mouse autosomes 8, 4 and 4, respectively, and contains the orthologous height genes PLAG1, CHCHD7, MOS, RPS20, LYN, RDHE2 (SDR16C5) and PENK. The region also overlapped 28 quantitative trait loci (QTLs) previously reported in literature by linkage mapping studies in cattle, including QTLs for birth weight, mature height, carcass weight, stature, pre-weaning average daily gain, calving ease, and gestation length.Conclusions: This study presents the first GWAS applying a high-density SNP panel to identify putative chromosome regions affecting birth weight in Nellore cattle. These results suggest that the QTLs on BTA14 associated with body size in taurine cattle (Bos primigenius taurus) also affect birth weight and size in zebu cattle (Bos primigenius indicus). © 2013 Utsunomiya et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The combination of sodium hypochlorite (NaOCl) and chlorhexidine (CHX) yields a precipitate potentially toxic (PPT). The aim of this study was to evaluate the tissue response to implanted polyethylene tubes filled with PPT-soaked fibrin sponge. Methods: Forty rats received four polyethylene tubes each; each tube was filled with fibrin sponge soaked by 2.5 % NaOCl, 2.0 % CHX, PPT (2.5 % NaOCl plus 2.0 % CHX), or not soaked (control). The observation time points were 7, 15, 30, 60, and 90 days. At each time point, eight animals were killed, and the tubes and surrounding tissues were removed, fixed, and prepared for light microscopic analysis by performing glycol methacrylate embedding, serial cutting into 3-μm sections, and hematoxylin-eosin staining. Qualitative and quantitative evaluations of the reactions were performed. Results were statistically analyzed by Kruskal-Wallis test (p < 0.05). Results: All chemical solutions caused moderate reactions at 7 days. On day 30, PPT group was more cytotoxic than the control group and the CHX group (p < 0.05). On days 15 and 60, PPT group was more cytotoxic than the control group (p < 0.05). On day 90, there was no statistically significant difference between the different groups. Conclusion: PPT is more cytotoxic than NaOCl and CHX alone, particularly in the short term. Clinical significance: Protocols which suggest the use of CHX and NaOCl must be revised because this mixture produces cytotoxic product. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural stability of vector fields with impasse regular curves on S2 is studied and a version of Peixoto's Theorem is established. Moreover a global analysis of normal forms of the constrained systems. A(x).ẋ=F(x),x∈R3,A∈M(3),F:R3→R3 in the Poincaré ball (i.e. in the compactification of R3 with the sphere S2 of the infinity) is made. © 2013 Elsevier Masson SAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behavior of the decay of velocity in a semi-dissipative one-dimensional Fermi accelerator model is considered. Two different kinds of dissipative forces were considered: (i) F-v and; (ii) F-v2. We prove the decay of velocity is linear for (i) and exponential for (ii). During the decay, the particles move along specific corridors which are constructed by the borders of the stable manifolds of saddle points. These corridors organize themselves in a very complicated way in the phase space leading the basin of attraction of the sinks to be seemingly of fractal type. © 2013 Elsevier B.V. All rights reserved.