231 resultados para Raio


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Have long studied the distribution of stresses in the cylinder. When this thickness is less than or equal to 10% of the inner radius is possible to consider a uniform distribution along the thickness of the tube. However, when the thickness is greater than 10% of the inner radius is necessary to consider the theory of thick-walled cylinders. This theory shows that when the thickness increases on the radius, the stresses do not act uniformly. The objective of this study is to determine the maximum stresses in thick-walled cylinders by comparing the results obtained by the theory of elasticity and the finite element method

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quality assurance control program (QACP) in clinical radiology is very important to acquire, image quality, patient dose reduction and cost for the institution. The verification of the real tension on the x ray tube, it is one of many parameters that may be determined on a QACP. This act on image quality as absorbed dose in patient. Once proved the importance of this fact, this study come up with the determination of tension to any X ray tube used on medical routine, on quick, safe and low cost manner. To reach the aim of this study, the methodology consisted on measuring expose rates (ER) using different thicknesses of copper (Cu) plates like filters and relating these results with Half Layer Value (HLV). Afterwards, the HLV was associated to real tension that was acquired with kilo voltage of peak (kVp) measurers used on clinical routine. So walking in this path, when performed the ER, on any X ray tube, it’s possible acquire the HLV and consequently the real kVp, considering measures obtained before, on the methodology of kVp estimative development

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study area is the Garoupa Field, located 75 km from the coast of Rio de Janeiro in bathymetric elevation of 125 m and it is the first important offshore discovery of the Campos Basin with hydrocarbon production in the Albian carbonates. The high significance of carbonate rock reservoirs for the global oil industry and its degree of complexity, combined with the fact that the Garoupa Field is a mature field, make this research project interesting to develop a re-exploratory vision of the study area. The objective of this paper is to characterize the physical properties of the Macae Group reservoirs in the Garoupa Field through well correlation techniques, petrophysical analysis and seismic interpretation (3D), in order to evaluate qualitatively and quantitatively the response of geophysical data to the presence of carbonate rock reservoirs. From the analysis of well profiles (gamma ray, resistivity, density and sonic) it was possible to identify six reservoir levels in the Quissamã Formation. As a result, the reservoirs have good correlation between the wells in the Garoupa Field and show lateral facies variation. In the seismic interpretation, structural contour maps were generated in time (ms) from the top of the Macae Group and two horizons that correspond to the reservoir levels. These maps show that the oil producing area of this field is a structural high located at the west of the interpreted seismic cube, and it was classified as a rollover limited by lateral faults forming a horst. The seismic attribute maps show a good response to the reservoirs of the Garoupa Field because they are associated with amplitude anomalies, verified by the correlation between the physical properties of the reservoir rock and seismic data through cross plots, with emphasis in a linear correlation between the resistivity profile and the values of Maximum Absolute Amplitude and RMS Amplitude attributes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we study some topics of Celestial Mechanics, namely the problem of rigid body rotation and “spin-orbit” resonances. Emphasis is placed on the problem formulation and applications to some exoplanets with physical parameters (e.g. mass and radius) compatible with a terrestrial type constitution (e.g. rock) belonging to multiple planetary systems. The approach is both analytical and numerical. The analytical part consists of: i) the deduction of the equation of motion for the rotation problem of a spherical body with no symmetry, disturbed by a central body; ii) modeling the same problem by including a third-body in the planet-star system; iii) formulation of the concept of “spin-orbit” resonance in which the orbital period of the planet is an integer multiple of the rotation’s period. Topics of dynamical systems (e.g. equilibrium points, chaos, surface sections, etc.) will be included at this stage. In the numerical part simulations are performed with numerical models developed in the previous analytical section. As a first step we consider the orbit of the planet not perturbed by a third-body in the star-planet system. In this case the eccentricity and orbital semi-major axis of the planet are constants. Here the technique of surface sections, widely used in dynamical systems are applied. Next, we consider the action of a third body, developing a more realistic model for planetary rotation. The results in both cases are compared. Since the technique of disturbed surface sections is no longer applicable, we quantitatively evaluate the evolution of the characteristic angles of rotation (e.g. physical libration) by studying the evolution of individual orbits in the dynamically important regions of phase space, the latter obtained in the undisturbed case

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A tectono-stratigraphic study of bivalve coquina-reservoir of Linguado Field allowed to identify two trends of permoporosity development. The delineation of these depositional-diagenetic traps were made through structural and stratigrafic cross-sections and maps. It resulted in the identification of shelf-ramp systems (tilted to SSE), it tickens from 60 to 70 meters and ends against an antithetic fault. The main coquina is bounded by fine siliciclastic units, white clay (low Gamma Ray values) or shale (high Gamma Ray values) lithologies, influencing diagenesis of basal or top coquina limestones (cimented, non-porous). Also in the middle of coquina-reservoir the “clayer” material is also associated with cemented carbonates, with also compartimentalize the reservoir into two subzones. The coquina porosity of the subzones is taken from density-neutron logs, while induction log estimates permeabilities and fluid saturations. It’s noticed the porosity development into pairs, good one followed by a regular/poor one and vice versa. These pairs form verticals succession, pair cycles where porosity improves or decreases upwards. These two scales of pore heterogeneity impose strong layering to the reservoir, and influences fluid saturations, oil-water contacts and porosity cut-offs. In a cross-section with density and induction logs, it can be observed the porosity variation along the shelf-ramp coquina (between 3LI_0004_RJS e 3RJS_0157C_RJ), the porosity is better developed in a downdip direction in the case of the two shelf wells, and also be the three ramp wells. The southern west downdip, 3RJS_0157C_RJ well, has best porosity pairs-cycles; however, its lowest structural conditions favour water saturation. Therefore it is fundamental for reservoir fluid evaluation a cross-plot analysis of RHOB-NPHI and Induction logs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The equine locomotors system alterations are very frequent and corresponds a large portion of cases in equine medicine. The most equine veterinarian’s challenge is to do a precise diagnosis of lameness cause to perform a specific and proper treatment as early as possible. The navicular syndrome is considered responsible for one third of lameness causes and, although much studied, its etiology is still not fully understood. The most varied methods of diagnosis, such as x-ray, magnetic resonance, bursography, scintigraphy, computed tomography and ultrasound, have been used to assess podotrochlear apparatus situation in order to diagnose this syndrome. Among them transcuneal ultrasound can be used to observe some important structures such as the flexor surface of distal sesamoid bone, distal deep digital flexor tendon, distal sesamoid ligament entheses odd and the distal phalanx. The aim of this present paper is provide a brief review on the use and the technique of ultrasonography on third phalanx transcuneal region evaluation and its interpretation on navicular syndrome diagnosis in horses

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The question of the solid waste is without a doubt one of the biggest problems faced for the world-wide population in the present time, resulting in the call “collapse of the garbage”. In this direction that appears the composting, in the scope of the treatment of organic waste origin, that in Brazil, approximately correspond 50% of the generated volume. However, the rare plants of selection and composting (UTC) existing at least do not obtain auto-to support themselves, increasing to each day the number of deactivations, almost always related the financial questions. In this direction, the present research brings the analysis of the economic viability of the implantation of a UTC for the city of Rio Claro-SP, relating it with the thick organic composition sales, for the cultures of vegetables cultivated in a ray of 30 km of the study area. For in such a way, they had been carried through, calculations concerning the regional demand for organic composition, and the verification of the implantation costs and operation of the plant. The reached results had been the flow of box for the first year of functioning of the UTC, as well as the break-even point between the gotten expenditures and prescriptions. From this relation investment profitability, it was verified that the UTC is presented impracticable under the economic point of view.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing demand for devices for solid state applications in many technological areas has resulted in a high demand for new materials. Among these material have the advantage of being manufactured with different chemical compositions, and may have physical properties equal to or higher than the corresponding crystalline material. The aim of this paper was to produce borate glass system 50B2O3 – 15CuO – 20Li2O – 15X (X = Na2O, K2O, RbCl e Cs2O) to analyze the influence of the atomic radius of alkali in the physical properties of this glass system. The glasses were synthesized by the process of melting and molding. The characteristic temperatures were determined by the technique of scanning calorimetry (DSC). The non-crystalline was determined by x-ray diffraction. In order to determine the molar volume a density measurement by using the Archimedes method was used. The structural characterization was carried out using the technique of infrared spectroscopy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determinate the multielemental concentrations in biological samples using the technique of total reflection X-ray fluorescence (TRFX) is essential the use of standard samples. The aim of this study is the determination of the sensitivities of the relevant elements in standard samples (Multi Element atomic spectroscopy standard solution in HNO3 I) prepared in three solutions with different and known concentrations. Based on the sensitivities of the elements contained in the multilelementar standard sample, it can estimate the sensitivity for an element found in the biological sample and consequently it is possible to determinate the concentration, even though the standard does not contain this element. The measurement of fluorescence was performed at the Brazilian Synchrotron Light Laboratory (LNLS) in Campinas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As normas nacionais e internacionais prevêem que a manutenção dos níveis de radiação deve estar abaixo do permitido. Sendo assim, a ICRP [1] (International Commission on Radiological Protection) exige métodos de otimização para garantir que o público esteja exposto aos menores níveis de radiação possíveis. Como método de otimização, aproximações teóricas e semi-empiricas podem realizar uma determinação do espectro de raios-X, sendo fundamental para o diagnóstico de energia, estimando a dose de radiações em pacientes e formulando modelos de blindagem. Métodos adequados de radioproteção foram desenvolvidos na física médica como a medicina nuclear, a radioterapia e a radiologia diagnóstica. Um dos métodos semi-empiricos utilizados é o modelo de TBC que é capaz de reproduzir e calcular os espectros gerados pelo anodo de tungstênio. Com o modelo de TBC modificado é possível também obedecer às exigências das barreiras protetoras presentes na radiologia, levando em conta a forma de onda arbitrária e a filtração adicional na geração do espectro não presente no modelo original. Além disso, realiza-se a calibração do espectro gerado para que o modelo de TBC represente a quantidade e comportamento de radiações típicas. Dessa forma, realiza-se uma revisão do modelo de TBC implementando-o ao programa matemático Matlab e comparando-o com os resultados adquiridos pelo Código MCNP-5 no Método de Monte Carlo. Os resultados encontrados são bastante satisfatórios, tanto em termos quantitativos quanto qualitativos dos feixes. Para a calibração, desenvolve-se uma análise dos espectros gerados pelo TBC Modificado aplicado ao programa Mathcad e Matlab sob as mesmas condições. Os espectros gerados apresentam o mesmo comportamento, diferindo em até 12% nos valores encontrados para camadas semi-redutoras, coeficiente de homogeneidade e energia efetiva

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The research involving new materials has always been considered as a differential in the development of a technology company. This occurred naturally since ancient times, often motivated by reasons of a certain age, where the most common material used was also the name of your time and may be cited as an example the Bronze Age, and later was the Iron. Currently, the use of firearms are they used in resolving conflicts between countries, or a more equivocal, as an instrument of social banditry make innovations in the area of shielding welcome, whether for personal use, in the form of vests or vehicle such as cars, tanks and even aircraft. In this context, is a Silicon Carbide Ceramic, with low density and high hardness. Thus, the aim of this study is the evaluation and comparison of these materials, seeking to improve their properties by means of additives such as boron and silicon metal and amorphous YAG. For this work, the specimens were pre-shaped by means of uniaxial later to be referred for isostatic pressing and sintering. The maximum percentage for each additive was 5%, except for the YAG whose percentage was 8.2% (mass percentage). All compositions were subjected to the same tests (x-ray diffraction, apparent density, optical microscopy, Vickers hardness, scanning electron Microscopita), so that one could draw a comparison between the materials under study, samples that showed better mechanical properties and micro structural, related here by hardness testing and microscopy (optical and SEM) were the silicon carbide doped with YAG and alumina samples, demonstrating the potential of these materials for ballistic protection. Other compositions have high porosity, which is highly undesirable, since in order to harmful influences on the mechanical properties discussed below

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present work was to evaluate surface of experimental alloy Ti-7.5Mo after hydrothermal treatment. Ingots were obtained in arc melting furnace under an argon atmosphere and then homogenized under vacuum at 1100ºC for 86.4 ks to eliminate chemical segregation and after cold worked discs were cutting and grinding. For surface treatment, samples were immersed in a container with NaOH aqueous solution 5M, autoclaved, washed with distilled water. Followed, samples were heat treated and they were soaking in 5xSBF to form an apatite layer on the surface. Surfaces were investigated by, scanning electron microscopy, X-Rays powder diffraction, atomic force microscopy and contact angle, in order to evaluate the wettability of the alloy surface. The results were compared with our previous studies using the group of chemical surface treatments and results shows better condition is 120 minutes in the autoclave