177 resultados para Porcelain veneer
Resumo:
Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core - MAu; zirconia core - MZi) and the quality of the veneer/core interface (complete bonded - MZi; incomplete bonded - MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The development of an accurate diagnosis and appropriate treatment plan can be a complex task, especially in cases of dentoalveolar trauma. The authors present a case report of crown-root fracture caused by trauma and highlight the importance of a multidisciplinary approach for the treatment. An eighteen year-old boy had a bicycle accident resulting in dental trauma. The upper right first molar showed a complicated crownroot fracture and the lower left second pre-molar showed an uncomplicated crown-root fracture. Endodontic treatment, controlled tooth extrusion, periodontal surgery for recovery of biological width, and porcelain crown and onlay restorations were performed. Esthetic and functional results were achieved. At the two-year follow-up it was observed that the tooth/onlay interface of the upper right first molar was stained and the onlay of the left lower second pre-molar was fractured. Therefore, the interface stained was repaired and a porcelain crown was made for the lower second premolar. The clinical case presented herein leads to the conclusion that a multidisciplinary treatment plan is extremely important for a proper resolution in cases of dentoalveolar trauma.
Resumo:
The demand for esthetic restorations has resulted in an increased use of dental ceramics and is the main alternative restorative material to tooth structure due to its favorable properties. Therefore, the aim of this work is to study the evolution of ceramic systems, involving different types and properties, indications, and clinical issues as aesthetic, cementing and longevity. In a detailed and advanced search in the database PubMed, 98 articles were found using the following key words: dental porcelain dental all-ceramic and ceramic according to the criteria for inclusion and exclusion left only 35 articles for review. Several ceramic systems are available in the market, making the prosthetic professionals need a constant recycling about their properties and directions, since good results are due to the selection of the best material for a particular case in all the skill of the practitioner.
Resumo:
Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.
Resumo:
Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.
Resumo:
The evolution of techniques and materials applied to adhesive ceramic restorations resulted in the intensification of its use, proving to be an excellent method of aesthetic restoration. Some important features of this technique are its conservative preparation, which avoids an excessive loss of tooth structure and its high aesthetic value provided by the ceramic even when utilized under different color of dental substrates. The aim of this paper was to report a clinical case with full crowns, porcelain veneers and non-prep veneers, enhancing peculiarities related to the material used, tooth preparation techniques, cementing, indications and contraindications.
Resumo:
The purpose of this study was to evaluate the effects of two conditioning methods used to enhance the shear strength of orthodontic brackets bonded to porcelain surfaces. A total of 18 feldspathic specimens were used. The specimens were divided randomly into two groups (n = 9): group free silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive); group silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by silane (Silano Ângelus) for 1 minute, adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive). All specimens were stored in solution of artificial saliva at ambient temperature for 24 hours. The debonding was done with shear strength through a universal testing machine (DL 500-Emic) calibrated with a fixed speed of 1mm/minute. Statical analysis was performed using the Student t test. The results indicated that in the free silane group the mean bond strength was 9,97 MPA, significantly lower than the silane group, that was 12,38 MPa (p < 0,05). The both groups were effective for bonding, although the silane group had the highest bond strength values.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)