342 resultados para Mandibular fossa


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypertrophy of the mandibular coronoid process is a rare condition, progressive and of unknown etiology, characterized by the over development of the coronoid process determining their size increased, resulting in progressive and painful limitation of mouth opening. The mandibular hypomobility is a present symptom in several diseases and associates it to a specific cause requires detailed clinical and imaginologic examination. The cone-beam computed tomography has the potential to provide complementary informations above than conventional radiography. It also has the advantage of eliminate overlaps, provide high resolution image, helping not only in diagnosis, but also in planning the surgical procedure. Here we report a case of male patient, who appeared at the clinic for an evaluation of a trismus. He had no pain, only discomfort for progressive limitation of mouth opening. On physical examination, only a limited mouth opening has been found. Although the movements of laterality and protrusión were posible, they were very limited. Cone-beam computed tomography examination was performed, that showed an image compatible with bilateral hypertrophy of the mandibular coronoid process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The authors tried to verify the anatomic location of the mandibular foramen and língula in dry jaws regarding the anterior and posterior border of the mandible and the incisure, alveolar border and mandibular base, in order to correlate the data with the sagittal split ramus osteotomy. Methods: There were evaluated 44 mandibles (88 sides) from the Morphology Department of the Araraquara Dental School of the São Paulo University (UNESP). The distances measured were previously deter - mined according to the figures presented in this article and were done by the use of a sliding caliper (Brow & Sharpe Digit-Cal Plus), with the mandibles positioned over a Erickson table, and the distan - ces were always measured in millimeters. Results: The pre-determined points and distances founded were X=17,67; Y=14,35; W=20,96 and Z=21,89 for the mandibular foramen, and the relationship between this anatomical structure and the língula shows that the mandibular foramen is in average 5,82 mm below the língula. Conclusions: The authors conclude that the mandibular foramen is lightly posterior in comparison with the ramus mandibular center and that the língula is a very important anatomic landmark for the ramus surgeries as well the knowledge of the distance between it and the mandibular foramen entrance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study is to report on the treatment of mandibular Class II furcation defects with enamel matrix protein derivative (EMD) combined with a beta TCP/HA (beta-tricalcium phosphate/hydroxyapatite) alloplastic material. Method and Materials: Thirteen patients were selected. All patients were nonsmokers, systemically healthy, and diagnosed with chronic periodontitis; had not taken medications known to interfere with periodontal tissue health and healing; presented one Class II mandibular furcation defect with horizontal probing equal to or greater than 4 mm at buccal site. The clinical parameters evaluated were probing depth (PD), relative gingival margin position (RGMP), relative vertical clinical attachment level (RVCAL), and relative horizontal clinical attachment level (RHCAL). A paired Student t test was used to detect differences between the baseline and 6-month measurements, with the level of significance of .05. Results: After 6 months, the treatment produced a statistically significant reduction in PD and a significant gain in RVCAL and RHCAL, but no observable change in RGMP. RVCAL ranged from 13.77 (+/- 1.31) at baseline to 12.15 (+/- 1.29) after 6 months, with a mean change of -1.62 +/- 1.00 mm (P<.05). RHCAL ranged from 5.54 (+/- 0.75) to 2.92 (+/- 0.92), with a mean change of -2.62 +/- 0.63 mm (P<.05). After 6 months, 76.92% of the patients improved their diagnosis to Class I furcation defects while 23.08% remained as Class II. Conclusion: The present study has shown that positive clinical results may be expected from the combined treatment of Class II furcation defects with EMD and beta TCP/HA, especially considering the gain of horizontal attachment level. Despite this result, controlled clinical studies are needed to confirm our outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AimThe aim of this study was to evaluate the healing of autologous bone block grafts or deproteinized bovine bone mineral (DBBM) block grafts applied concomitantly with collagen membranes for horizontal alveolar ridge augmentation.Material and methodsIn six Labrador dogs, molars were extracted bilaterally, the buccal bony wall was removed, and a buccal box-shaped defect created. After 3months, a bony block graft was harvested from the right ascending ramus of the mandible and reduced to a standardized size. A DBBM block was tailored to similar dimensions. The two blocks were secured with screws onto the buccal wall of the defects in the right and left sides of the mandible, respectively. Resorbable membranes were applied at both sides, and the flaps sutured. After 3months, one implant was installed in each side of the mandible, in the interface between grafts and parent bone. After 3months, biopsies were harvested and ground sections prepared to reveal a 6-month healing period of the grafts.Results776.2% and 5.9 +/- 7.5% of vital mineralized bone were found at the autologous bone and DBBM block graft sites, respectively. Moreover, at the DBBM site, 63 +/- 11.7% of connective tissue and 31 +/- 15.5% of DBBM occupied the area analyzed. Only 0.2 +/- 0.4% of DBBM was found in contact with newly formed bone. The horizontal loss was in a mean range of 0.9-1.8mm, and 0.3-0.8mm, at the autologous bone and DBBM block graft sites, respectively.ConclusionsAutologous bone grafts were vital and integrated to the parent bone after 6months of healing. In contrast, DBBM grafts were embedded into connective tissue, and only a limited amount of bone was found inside the scaffold of the biomaterial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim of this prospective study was to objectively evaluate the inferior alveolar nerve (IAN) sensory disturbances in patients who underwent sagittal split ramus osteotomy (SSRO) and its spontaneous recovery and to define the incidence of sensibility loss, time, and area at which the recovery occurs. Patients and Methods Clinical evaluation of the IAN sensory disturbance was undertaken preoperatively and at the first week, fourth week, 2 months, and 6 months postoperatively in 30 patients who underwent SSRO at the Oral and Maxillofacial Surgery Division of the Araraquara Dental School--Unesp and at the Plastic Surgery Division of the Medical Sciences School--Unicamp. The 30 patients were examined at all periods regarding the IAN functionality by Semmes-Weinstein testing. Results The mean age of the patients included in this study was 29.36 years old. All patients showed sensibility loss at the 7-day evaluation time. The comparison between sides, gender, and age did not show any significant difference. In most of the examined zone, the data collected at 6 months were statistically similar to the data collected at the preoperative period. All zones presented significant recovery, starting from 30 days after surgery. Twenty patients had total spontaneous recovery at the final period, in all examined zones. Conclusions The SSRO presents the disadvantage of temporary paresthesia; however, spontaneous nerve function recovery does occur. The Semmes-Weinstein test is a reliable, inexpensive, and easy-to-apply tool, which can be used for clinical evaluation on a daily basis at offices and hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.