226 resultados para Laser therapy low-level. Exercise. Electromyography. Muscle strength dynamometer
Resumo:
OBJETIVO: Investigar os fatores associados à diferença clinicamente significativa da qualidade de vida (DCSQV) após condicionamento físico em pacientes com DPOC. MÉTODOS: Trinta e cinco pacientes foram submetidos a 12 semanas de condicionamento físico, envolvendo treinamento de força e exercício aeróbio leve. Composição corporal, teste incremental e de endurance em esteira, teste de caminhada de seis minutos, força muscular periférica, PImáx, baseline dyspnea index (BDI) e Saint George's Respiratory Questionnaire (SGRQ) foram avaliados antes e após o treinamento, e suas alterações (Δ) foram calculadas. A DCSQV foi definida como a redução > 4% no escore total do SGRQ. Os pacientes que responderam ao treinamento, apresentando DCSQV, foram alocados no grupo respondedores (R; n = 24), e os demais pacientes foram alocados no grupo não-respondedores (NR; n = 11). RESULTADOS: Os seguintes resultados foram significativamente maiores no grupo R que no grupo NR (p < 0,05): VEF1 (1,48 ± 0,54 L vs. 1,04 ± 0,34 L), VEF1/CVF (47,9 ± 11,7% vs. 35,5 ± 10,7%), PaO2 (74,1 ± 9,7 mmHg vs. 65,0 ± 8,9mmHg) e ΔBDI [mediana (interquartil); 2,0 (0,0-3,5) vs. 0,0 (0,0-1,0)]. Houve correlação significativa (p < 0,01) de ΔSGRQ-sintomas (r = 0,44), ΔSGRQ-atividade (r = 0,62) e ΔSGRQ-total (r = 0,60) com ΔBDI. Após regressão logística, apenas ΔBDI foi selecionado como determinante da DCSQV. CONCLUSÕES: A DCSQV após o condicionamento físico está associada principalmente à redução da dispneia nos pacientes com DPOC. Portanto, são necessárias estratégias de tratamento visando interromper o ciclo dispneia-sedentarismo-dispneia nesses pacientes.
Resumo:
Little evidence-based guidance is available to aid clinicians in determining short-term prognoses in very severe COPD patients. Therefore, the present study was designed to provide a prospective assessment (1) of the mortality rates and (2) whether the baseline measurements may be determinants of 1-year mortality in hypoxemic COPD patients receiving long-term oxygen therapy (LTOT).Seventy-eight clinically stable patients with advanced COPD treated using LTOT were enrolled in a prospective cohort study. Outcome variable: first-year mortality. Baseline measurements: categorical variables: age (<60 or >= 60 years); gender; body mass index (<20 or >= 20 kg/m(2)); fat-free mass (FFM) index (<16 [men] and <15kg/m(2) [women]; baseline dyspnea index (BDI) (<= 3 or >3); and corticosteroid use. Continuous variables: smoking history; lung function; FFM; fat mass; hemoglobin; hematocrit; arterial blood gases; forearm muscle strength; St. George's Respiratory Questionnaire (SGRQ); and comorbidity score. By the end of 1-year of follow-up, 12 patients (15.4%) had died. Kaplan-Meier curves showed that BDI <= 3 was the only variable associated with higher mortality. Cox proportional hazards analysis revealed that tower PaO2 and SPO2, higher PaCO2 and SGRQ scores were associated with reduced survival. In the multivariate analysis, BDI remained predictive of mortality (hazard ratio [HR], 0.50; 95% confidence interval [CI], 0.31-0.81), as did PaO2 (HR, 0.49; 95% CI, 0.26-0.95). These data suggest that readily available parameters as dyspnea intensity and hypoxemia severity may be useful in predicting first-year survival rates in advanced COPD patients receiving LTOT (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this study was to investigate the bond strength of fiber post previously laser treated root canals. Forty single-rooted bovine teeth were endodontically treated, randomly and equally divided into two main groups according to the type of pretreatment: G1: 2.5% NaOCl (control group); and G2: Er,Cr:YSGG laser. Each group was further subdivided into 2 groups based on the category of adhesive systems/ luting materials used: a: an etch-and-rinse resin cement (Single Bond/RelyX ARC; 3M ESPE), and b: a self-adhesive resin cement (Rely X Unicem; 3M ESPE). Three 1.5 mm thick slabs were obtained per root and the push-out test was performed at a crosshead speed of 0.5 mm/min until post dislodgement occurred. Data were analyzed by ANOVA and post-hoc Tukey's test at a pre-set alpha of 0.05. Analysis of variance showed no statistically significant difference (p > 0.05) among the groups G1a (25.44 ± 2.35) and G1b (23.62 ± 3.48), G2a (11.77 ± 2.67) and G2b (9.93 ± 3.37). Fractures were observed at the interface between the dentin and the resin in all groups. The Er,Cr:YSGG laser irradiation did not influence on the bond strength of the resin cements and the etch-and-rinse resin cement had better results on bond strength than self-adhesive resin cement.
Resumo:
The objective this study was to evaluate in vitro the bond strength of two etch-and-rise and one self-etching adhesive system after dentin irradiation with Er:YAG (erbium: yttrium aluminum garnet) laser using microtensile test. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strength, independently to the adhesive system used. The prompt L-pop adhesive presented less microtensile bond strength compared to the other adhesives evaluated. There was no difference between single bond and excite groups. The adhesive failures were predominant in all the experimental groups. The Er:YAG laser influenced negatively bond strength values of adhesive systems tested in dental substrate.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).
Resumo:
The effects of adding L-carnitine to a whole-body and respiratory training program were determined in moderate-to-severe chronic obstructive pulmonary disease (COPD) patients. Sixteen COPD patients (66 ± 7 years) were randomly assigned to L-carnitine (CG) or placebo group (PG) that received either L-carnitine or saline solution (2 g/day, orally) for 6 weeks (forced expiratory volume on first second was 38 ± 16 and 36 ± 12%, respectively). Both groups participated in three weekly 30-min treadmill and threshold inspiratory muscle training sessions, with 3 sets of 10 loaded inspirations (40%) at maximal inspiratory pressure. Nutritional status, exercise tolerance on a treadmill and six-minute walking test, blood lactate, heart rate, blood pressure, and respiratory muscle strength were determined as baseline and on day 42. Maximal capacity in the incremental exercise test was significantly improved in both groups (P < 0.05). Blood lactate, blood pressure, oxygen saturation, and heart rate at identical exercise levels were lower in CG after training (P < 0.05). Inspiratory muscle strength and walking test tolerance were significantly improved in both groups, but the gains of CG were significantly higher than those of PG (40 ± 14 vs 14 ± 5 cmH2O, and 87 ± 30 vs 34 ± 29 m, respectively; P < 0.05). Blood lactate concentration was significantly lower in CG than in PG (1.6 ± 0.7 vs 2.3 ± 0.7 mM, P < 0.05). The present data suggest that carnitine can improve exercise tolerance and inspiratory muscle strength in COPD patients, as well as reduce lactate production.
Resumo:
OBJETIVO: Avaliar os níveis de L-carnitina livre no plasma, o estado nutricional, a função pulmonar e a tolerância ao exercício em pacientes com doença pulmonar obstrutiva crônica e verificar as correlações entre a composição corporal e as frações de L-carnitina no plasma. MÉTODOS: Quarenta pacientes entre 66,2±9 anos, com diagnóstico clínico de doença pulmonar obstrutiva crônica, foram divididos em dois grupos: G1, com índice de massa corporal menor que 20kg/m², e G2, com índice de massa corporal maior que 20kg/m². Foram mensurados os parâmetros espirométricos, a tolerância ao exercício no teste de caminhada, a força muscular respiratória, a composição corporal por meio da impedância bioelétrica e as dosagens da L-carnitina plasmática, através de amostras de sangue. RESULTADOS: Foram observados menores valores das variáveis espirométricas (p<0,01), da força muscular respiratória e dos níveis de L-carnitina nos pacientes do G1; porém, não houve diferença entre os grupos quanto à capacidade de realizar exercício físico dinâmico de baixa intensidade. Correlações significativas entre o percentual de gordura e os níveis de L-carnitina plasmática foram observadas nos pacientes (r=0,53 com p<0,002); sendo que, nos pacientes com índice de massa corporal menor que 18kg/m², essa relação aumentou (r<0,73 com p<0,01). CONCLUSÃO: Na doença pulmonar obstrutiva crônica, a desnutrição está associada tanto aos prejuízos da função pulmonar e da força muscular respiratória, quanto aos baixos níveis de L-Carnitina plasmática.
Resumo:
This study was conducted to analyze the ablation rate and micromorphological aspects of microcavities in enamel and dentin of primary and permanent teeth using a Er:YAG laser system. Micromorphological evaluation has been performed in terms of permanent teeth; however, little information about Er: YAG laser interaction with primary teeth can be found in the literature. Because children have been the most beneficiary patients with laser therapy in our offices, it is extremely necessary to compare the effects of this kind of laser system on the enamel and dentin of permanent and primary teeth. In this study, we used eleven intact primary anterior exfoliated teeth and six extracted permanent molar teeth. We used a commercial laser system: a Er: YAG Twin Light laser system (Fotona Medical Lasers, Slovenia) at 2940 nm, changing average energy levels per pulse ( 100, 200, 300, and 400 mJ) producing 48 microcavities in enamel and dentin of primary and permanent teeth. Primary teeth are more easily ablated than are permanent teeth, when related to enamel or dentin. However, while this laser system is capable of slowly revealing the enamel's microstructure, in dentin only the lowest laser energies permit this kind of observation, more easily decomposing the original tissue aspect, when related to primary or permanent teeth. Statistically, the only different factor at the 5% level was an energy per pulse of 400 mJ, confirming the results found in SEM. Our results showed that dentin in both primary and permanent teeth is less resistant to Er: YAG laser ablation; this fact is easily observed under SEM observation and through the ablation rate evaluation.
Resumo:
Background: Low intensity laser therapy has been recommended to support the cutaneous repair; however, so far studies do not have evaluated the tissue response following a single laser treatment. This study investigated the effect of a single laser irradiation on the healing of full-thickness skin lesions in rats.Methods: Forty-eight male rats were randomly divided into three groups. One surgical lesion was created on the back of rats using a punch of 8 mm in diameter. One group was not submitted to any treatment after surgery and it was used as control. Two energy doses from an 830-nm near-infrared diode laser were used immediately post-wounding: 1.3 J cm(-2) and 3 J cm(-2). The laser intensity 53 mW cm(-2) was kept for both groups. Biometrical and histological analyses were accomplished at days 3, 7 and 14 post-wounding.Results: Irradiated lesions presented a more advanced healing process than control group. The dose of 1.3 J cm(-2) leaded to better results. Lesions of the group irradiated with 1.3 J cm(-2) presented faster lesion contraction showing quicker re-epithelization and reformed connective tissue with more organized collagen fibers.Conclusions: Low-intensity laser therapy may accelerate cutaneous wound healing in a rat model even if a single laser treatment is performed. This finding might broaden current treatment regimens. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.
Resumo:
It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.