Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)
Resumo:
This article presents an automatic methodology for extraction of road seeds from high-resolution aerial images. The method is based on a set of four road objects and another set of connection rules among road objects. Each road object is a local representation of an approximately straight road fragment and its construction is based on a combination of polygons describing all relevant image edges, according to some rules embodying road knowledge. Each one of the road seeds is composed by a sequence of connected road objects, in which each sequence of this type can be geometrically structured as a chain of contiguous quadrilaterals. Experiments carried out with high-resolution aerial images showed that the proposed methodology is very promising in extracting road seeds. This article presents the fundamentals of the method and the experimental results, as well.
Resumo:
The assessment of welfare issues has been a challenge for poultry producers, and lately welfare standards needs to be reached in order to agree with international market demand. This research proposes the use of continuous behavior monitoring in order to contribute for assessing welfare. A software was developed using the language Clarium. The software managed the recording of data as well as the data searching in the database Firebird. Both software and the observational methodology were tested in a trial conducted inside an environmental chamber, using three genetics of broiler breeders. Behavioral pattern was recorded and correlated to ambient thermal and aerial variation. Monitoring video cameras were placed on the roof facing the used for registering the bird's behavior. From video camera images were recorded during the total period when the ambient was bright, and for analyzing the video images a sample of 15min observation in the morning and 15 min in the afternoon was used, adding up to 30 min daily observation. A specific model so-called behavior was developed inside the software for counting specific behavior and its frequency of occurrence, as well as its duration. Electronic identification was recorded for 24h period. Behavioral video recording images was related to the data recorded using electronic identification.. Statistical analysis of data allowed to identify behavioral differences related to the change in thermal environment, and ultimately indicating thermal stress and departure from welfare conditions.
Resumo:
This paper seeks to apply a routine for highways detection through the mathematical morphology tools in high resolution image. The Mathematical Morphology theory consists of describing structures geometric presents quantitatively in the image (targets or features). This explains the use of the Mathematical Morphology in this work. As high resolution images will be used, the largest difficulty in the highways detection process is the presence of trees and automobiles in the borders tracks. Like this, for the obtaining of good results through the use of morphologic tools was necessary to choose the structuring element appropriately to be used in the functions. Through the appropriate choice of the morphologic operators and structuring elements it was possible to detect the highways tracks. The linear feature detection using mathematical morphology techniques, can contribute in cartographic applications, as cartographic products updating.
Resumo:
Medical images are private to doctor and patient. Digital medical images should be protected against unauthorized viewers. One way to protect digital medical images is using cryptography to encrypt the images. This paper proposes a method for encrypting medical images with a traditional symmetric cryptosystem. We use biometrics to protect the cryptographic key. Both encrypted image and cryptographic key can be transmitted over public networks with security and only the person that owns the biometrics information used in key protection can decrypt the medical image. © Springer Science+Business Media B.V. 2008.
Resumo:
The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.
Resumo:
Aim: To assess the bone mineral density on conventional and digitized images, comparing whether different parameters of digitization and storage change these values. Methods: Twenty radiographs were taken from five partially dentulous dry mandibles with an aluminum 7-mm stepwedge placed on the superior edge of the film. After processing, the films were digitized with a resolution of 600 and 2,400 d.p.i. and saved as TIFF and JPEG files. On every conventional and digitized image, circular regions of interest were selected for densitometry and radiographic contrast analysis. Results: Pearson's correlation coefficient showed a significant and strong mean gray values association between digitized and conventional images, differing from radiographic contrast that did not show a significant association. ANOVA did not reveal a statistically significant difference in bone density and radiographic contrast among the four digitized image groups, but the conventional image contrast was significantly lower. Conclusions: Bone mineral density did not differ in both conventional and digitized images. The parameters of image compression and resolution, tested in this study, did not change the results of densitometry and digitization process increased the radiographic contrast.
Resumo:
Palatal rugoscopy, or palatoscopy, is the process by which human identification can be obtained by inspecting the transverse palatal rugae inside the mouth. Aim: This study evaluated a digital method for human identification using palatoscopy, by comparing photographs of the palate against the images of cast models of the maxilla photographed with and without highlighting of the palatal rugae. Methods: Condensation silicone impressions were made from the upper arches of 30 adult subjects of both genders and their palates were then photographed. The first impression was made with heavy silicone, the second impression with light silicone, and then the models were cast in improved type IV dental stone. The casts were photographed, the palatal rugae of each one were highlighted with a pencil, and then the models were photographed again. Using a free image-editing software, the digital photographs were overlapped over the images of the palatal rugae of the models with and without highlighting of the palatal rugae, in order to identify the pairs. Results: The result of overlapping the digital photographs with the images of the models without highlighted palatal rugae resulted in 90% positive identification. For the overlapping of the digital photographs with the images of models with highlighted palatal rugae, there was 100% positive identification. Conclusions: The digital method evaluated in this study was proven effective for human identification.
Resumo:
This paper presents a method for indirect orientation of aerial images using ground control lines extracted from airborne Laser system (ALS) data. This data integration strategy has shown good potential in the automation of photogrammetric tasks, including the indirect orientation of images. The most important characteristic of the proposed approach is that the exterior orientation parameters (EOP) of a single or multiple images can be automatically computed with a space resection procedure from data derived from different sensors. The suggested method works as follows. Firstly, the straight lines are automatically extracted in the digital aerial image (s) and in the intensity image derived from an ALS data-set (S). Then, correspondence between s and S is automatically determined. A line-based coplanarity model that establishes the relationship between straight lines in the object and in the image space is used to estimate the EOP with the iterated extended Kalman filtering (IEKF). Implementation and testing of the method have employed data from different sensors. Experiments were conducted to assess the proposed method and the results obtained showed that the estimation of the EOP is function of ALS positional accuracy.
Resumo:
The aim of this work is to evaluate the influence of point measurements in images, with subpixel accuracy, and its contribution in the calibration of digital cameras. Also, the effect of subpixel measurements in 3D coordinates of check points in the object space will be evaluated. With this purpose, an algorithm that allows subpixel accuracy was implemented for semi-automatic determination of points of interest, based on Fõrstner operator. Experiments were accomplished with a block of images acquired with the multispectral camera DuncanTech MS3100-CIR. The influence of subpixel measurements in the adjustment by Least Square Method (LSM) was evaluated by the comparison of estimated standard deviation of parameters in both situations, with manual measurement (pixel accuracy) and with subpixel estimation. Additionally, the influence of subpixel measurements in the 3D reconstruction was also analyzed. Based on the obtained results, i.e., on the quantification of the standard deviation reduction in the Inner Orientation Parameters (IOP) and also in the relative error of the 3D reconstruction, it was shown that measurements with subpixel accuracy are relevant for some tasks in Photogrammetry, mainly for those in which the metric quality is of great relevance, as Camera Calibration.
Resumo:
Digital techniques have been developed and validated to assess semiquantitatively immunohistochemical nuclear staining. Currently visual classification is the standard for qualitative nuclear evaluation. Analysis of pixels that represents the immunohistochemical labeling can be more sensitive, reproducible and objective than visual grading. This study compared two semiquantitative techniques of digital image analysis with three techniques of visual analysis imaging to estimate the p53 nuclear immunostaining. Methods: Sixty-three sun-exposed forearm-skin biopsies were photographed and submitted to three visual analyses of images: the qualitative visual evaluation method (0 to 4 +), the percentage of labeled nuclei and HSCORE. Digital image analysis was performed using ImageJ 1.45p; the density of nuclei was scored per ephitelial area (DensNU) and the pixel density was established in marked suprabasal epithelium (DensPSB). Results: Statistical significance was found in: the agreement and correlation among the visual estimates of evaluators, correlation among the median visual score of the evaluators, the HSCORE and the percentage of marked nuclei with the DensNU and DensPSB estimates. DensNU was strongly correlated to the percentage of p53-marked nuclei in the epidermis, and DensPSB with the HSCORE. Conclusion: The parameters presented herein can be applied in routine analysis of immunohistochemical nuclear staining of epidermis. © 2012 John Wiley & Sons A/S.
Resumo:
Image acquisition systems based on multi-head arrangement of digital camerasare attractive alternatives enabling a larger imaging area when compared to a single framecamera. The calibration of this kind of system can be performed in several steps or byusing simultaneous bundle adjustment with relative orientation stability constraints. Thepaper will address the details of the steps of the proposed approach for system calibration,image rectification, registration and fusion. Experiments with terrestrial and aerial imagesacquired with two Fuji FinePix S3Pro cameras were performed. The experiments focusedon the assessment of the results of self-calibrating bundle adjustment with and withoutrelative orientation constraints and the effects to the registration and fusion when generatingvirtual images. The experiments have shown that the images can be accurately rectified andregistered with the proposed approach, achieving residuals smaller than one pixel. © 2013 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Intestinal parasitosis constitutes a serious health problem in most tropical countries. The diagnosis of enteroparasites in laboratory routine relies on the examination of stool samples using optical microscopy and the error rates usually range from moderate to high. Approaches based on automatic image analysis have been proposed, but the methods are usually specific for some species, some of them are computationally expensive, and image acquisition and focus are manual. We present a solution to automate the diagnosis of the 15 most common species of enteroparasites in Brazil, using a sensitive parasitological technique, a motorized microscope with digital camera for automatic image acquisition and focus, and fast image analysis methods. The results indicate that our solution is effective and suitable for laboratory routine, in which the exam must be concluded in a few minutes. © 2013 IEEE.