206 resultados para Avanço mandibular
Resumo:
Jaws atrophy represents a great challenge to Implantology regarding rehabilitation of edentulous areas. This paper reports an extreme mandibular atrophy with only 9mm of height between the mental foramina. In these situations, treatment options include bone augmentation techniques, transmandibular, or short dental implants. It is well accepted that bone grafts to improve height do not have good predictability. Besides, osteogenic distraction is associated with a great patient discomfort and transmandibular implants are related with high failure rates. Also, surgical-prosthetic rehabilitations with short dental implants had been associated to good success rates. The purpose of this clinical case is to report a severe mandibular atrophy, successfully treated with four short dental implants between mental foramina for implant-supported prosthesis.
Resumo:
The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.
Resumo:
The incidence of fractures of the atrophic edentulous mandible is still low, even with the increasing life expectancy. The reduced blood supply of the sclerotic bone, the diminished contact area between bone fragments and the patient’s systemic condition makes the treatment of those fractures a challenge for any professional. Treatment of atrophic mandibular fractures by means of miniplate osteosynthesis has not been the preferred method of fixa- tion by many authors. Yet, many surgeons have applied this type of fixation for the atrophied jaw sections. This paper reports 2 cases of fractured atrophic mandibles treated with the pencilboneplate, a monocortical 2.0 mm titanium, 8 or 10-hole hardware with reinforcement on its middle portion, highlighting important considerations of its use. The pencilboneplate appears to be a valuable option for the treatment of atrophic mandibular fractures, espe- cially by an intra-oral approach, and warrants further bio- mechanical and clinical studies.
Resumo:
Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.
Resumo:
Osteochondroma (OC) is the most common benign tumor of long bones. However it is rarely found in the facial skeleton, being the coronoid process and mandibular condyle the most affected sites in this region. It basically consists in bone growth covered by cartilage. The etiology is still controversial: neoplastic, developmental, reparative and traumatic origins have been discussed in literature. The treatments of these lesions include total condylectomy or local resection of the lesion. This paper aims to report a case of a patient with history of trauma and possible fracture of the mandibular condyle in childhood, which in youth developed dentofacial deformity with severe facial asymmetry. The treatment consisted of resection of lesion both with maxillary and mandibular osteotomies associated with graft from the iliac crest bone. Actually, the patient is with a favorable aesthetic, without functional deficit and absence of lesion’s recurrence.
Resumo:
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Resumo:
The contemporary implant dentistry is in constant technological development, improving the oral rehabilitation process of partial or totally edentulous patients. On the other hand, anatomical limitations, such as the maxillary sinus and the mandibular canal in the posterior region of the jaws can limit the implant placement. Furthermore, due to the absence of dental elements, alveolar ridge atrophy is frequently observed. This aspect represents a loss either in quantity or quality of the bone tissue available for the dental implant rehabilitation. To make possible the dental implant rehabilitation even in adverse conditions, some solutions have been considered, such as the use of short implants (≤ 10 mm length) and/or small diameter implants (2,8; 3,3 and 3,5 mm width). The aim of this study is to present a literature review considering the use of short implants in oral rehabilitation, presenting the currently view of the matter. Based on the literature review, the use of short implants produced similar clinical success to conventional implants (greater than 10 mm in length). Therefore, its use can be considered a viable alternative, where anatomical limitations are present.
Resumo:
The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.
Resumo:
The hypertrophy of the mandibular coronoid process is a rare condition, progressive and of unknown etiology, characterized by the over development of the coronoid process determining their size increased, resulting in progressive and painful limitation of mouth opening. The mandibular hypomobility is a present symptom in several diseases and associates it to a specific cause requires detailed clinical and imaginologic examination. The cone-beam computed tomography has the potential to provide complementary informations above than conventional radiography. It also has the advantage of eliminate overlaps, provide high resolution image, helping not only in diagnosis, but also in planning the surgical procedure. Here we report a case of male patient, who appeared at the clinic for an evaluation of a trismus. He had no pain, only discomfort for progressive limitation of mouth opening. On physical examination, only a limited mouth opening has been found. Although the movements of laterality and protrusión were posible, they were very limited. Cone-beam computed tomography examination was performed, that showed an image compatible with bilateral hypertrophy of the mandibular coronoid process.
Resumo:
Purpose: The authors tried to verify the anatomic location of the mandibular foramen and língula in dry jaws regarding the anterior and posterior border of the mandible and the incisure, alveolar border and mandibular base, in order to correlate the data with the sagittal split ramus osteotomy. Methods: There were evaluated 44 mandibles (88 sides) from the Morphology Department of the Araraquara Dental School of the São Paulo University (UNESP). The distances measured were previously deter - mined according to the figures presented in this article and were done by the use of a sliding caliper (Brow & Sharpe Digit-Cal Plus), with the mandibles positioned over a Erickson table, and the distan - ces were always measured in millimeters. Results: The pre-determined points and distances founded were X=17,67; Y=14,35; W=20,96 and Z=21,89 for the mandibular foramen, and the relationship between this anatomical structure and the língula shows that the mandibular foramen is in average 5,82 mm below the língula. Conclusions: The authors conclude that the mandibular foramen is lightly posterior in comparison with the ramus mandibular center and that the língula is a very important anatomic landmark for the ramus surgeries as well the knowledge of the distance between it and the mandibular foramen entrance.
Resumo:
Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objectives: The aim of this study is to report on the treatment of mandibular Class II furcation defects with enamel matrix protein derivative (EMD) combined with a beta TCP/HA (beta-tricalcium phosphate/hydroxyapatite) alloplastic material. Method and Materials: Thirteen patients were selected. All patients were nonsmokers, systemically healthy, and diagnosed with chronic periodontitis; had not taken medications known to interfere with periodontal tissue health and healing; presented one Class II mandibular furcation defect with horizontal probing equal to or greater than 4 mm at buccal site. The clinical parameters evaluated were probing depth (PD), relative gingival margin position (RGMP), relative vertical clinical attachment level (RVCAL), and relative horizontal clinical attachment level (RHCAL). A paired Student t test was used to detect differences between the baseline and 6-month measurements, with the level of significance of .05. Results: After 6 months, the treatment produced a statistically significant reduction in PD and a significant gain in RVCAL and RHCAL, but no observable change in RGMP. RVCAL ranged from 13.77 (+/- 1.31) at baseline to 12.15 (+/- 1.29) after 6 months, with a mean change of -1.62 +/- 1.00 mm (P<.05). RHCAL ranged from 5.54 (+/- 0.75) to 2.92 (+/- 0.92), with a mean change of -2.62 +/- 0.63 mm (P<.05). After 6 months, 76.92% of the patients improved their diagnosis to Class I furcation defects while 23.08% remained as Class II. Conclusion: The present study has shown that positive clinical results may be expected from the combined treatment of Class II furcation defects with EMD and beta TCP/HA, especially considering the gain of horizontal attachment level. Despite this result, controlled clinical studies are needed to confirm our outcomes.