409 resultados para Autogenous grinding


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This patient report presents an unusual onlay bone graft failure following local cocaine application. Three months after the bone grafting procedure performed in the anterior maxilla for bone volume augmentation, the bone graft was totally exposed in the oral cavity as a result of the rubbing of cocaine on the gingival tissue that covered the bone graft. A histologic view of the removed bone fragment presented not only an area of necrosis but also ample spaces filled with necrosis material and resorption areas. Dental practitioners need to be aware of this phenomenon because such patients often do not report the use of drugs, particularly cocaine. Copyright © 2005 by Lippincott Williams & Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Recent clinical studies have described maxillary sinus floor augmentation by simply elevating the maxillary sinus membrane without the use of adjunctive grafting materials. Purpose: This experimental study aimed at comparing the histologic outcomes of sinus membrane elevation and simultaneous placement of implants with and without adjunctive autogenous bone grafts. The purpose was also to investigate the role played by the implant surface in osseointegration under such circumstances. Materials and Methods: Four tufted capuchin primates had all upper premolars and the first molar extracted bilaterally. Four months later, the animals underwent maxillary sinus membrane elevation surgery using a replaceable bone window technique. The schneiderian membrane was kept elevated by insertion of two implants (turned and oxidized, Brånemark System®, Nobel Biocare AB, Göteborg, Sweden) in both sinuses. The right sinus was left with no additional treatment, whereas the left sinus was filled with autogenous bone graft. Implant stability was assessed through resonance frequency analysis (Osstell™, Integration Diagnostics AB, Göteborg, Sweden) at installation and at sacrifice. The pattern of bone formation in the experimental sites and related to the different implant surfaces was investigated using fluorochromes. The animals were sacrificed 6 months after the maxillary sinus floor augmentation procedure for histology and histomorphometry (bone-implant contact, bone area in threads, and bone area in rectangle). Results: The results showed no differences between membrane-elevated and grafted sites regarding implant stability, bone-implant contacts, and bone area within and outside implant threads. The oxidized implants exhibited improved integration compared with turned ones as higher values of bone-implant contact and bone area within threads were observed. Conclusions: The amount of augmented bone tissue in the maxillary sinus after sinus membrane elevation with or without adjunctive autogenous bone grafts does not differ after 6 months of healing. New bone is frequently deposited in contact with the schneiderian membrane in coagulum-alone sites, indicating the osteoinductive potential of the membrane. Oxidized implants show a stronger bone tissue response than turned implants in sinus floor augmentation procedures. © 2006 Blackwell Publishing, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acellular dermal matrix allograft has been used as an alternative to autogenous palatal mucosal graft. The aim of this study was the evaluation of the biocompatibility of an acellular dermal matrix (AlloDerm®) in culture of macrophages. For hydrogen peroxidase determination we used the method of Pick & Kesari, and the Griess method for nitric oxide determination,. Statistical analysis showed no significant difference (p ≤ 0,05) in the release of nitric oxide and hydrogen peroxide by the macrophages exposed to acellular dermal matrix and the negative control. The results suggest that acellular dermal matrix did not activate the cell inflammatory response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work involved the development of a smart system dedicated to surface burning detection in the grinding process through constant monitoring of the process by acoustic emission and electrical power signals. A program in Visual Basic® for Windows® was developed, which collects the signals through an analog-digital converter and further processes them using burning detection algorithms already known. Three other parameters are proposed here and a comparative study carried out. When burning occurs, the newly developed software program sends a control signal warning the operator or interrupting the process, and delivers process information via the Internet. Parallel to this, the user can also interfere in the process via Internet, changing parameters and/or monitoring the grinding process. The findings of a comparative study of the various parameters are also discussed here. Copyright © 2006 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents specific cutting energy measurements as a function of the cutting speed and tool cutting edge geometry. The experimental work was carried out on a vertical CNC machining center with 7,500 rpm spindle rotation and 7.5 kW power. Hardened steels ASTM H13 (50 HRC) were machined at conventional cutting speed and high-speed cutting (HSC). TiN coated carbides with seven different geometries of chip breaker were applied on dry tests. A special milling tool holder with only one cutting edge was developed and the machining forces needed to calculate the specific cutting energy were recorded using a piezoelectric 4-component dynamometer. Workpiece roughness and chip formation process were also evaluated. The results showed that the specific cutting energy decreased 15.5% when cutting speed was increased up to 700%. An increase of 1 °in tool chip breaker chamfer angle lead to a reduction in the specific cutting energy about 13.7% and 28.6% when machining at HSC and conventional cutting speed respectively. Furthermore the workpiece roughness values evaluated in all test conditions were very low, closer to those of typical grinding operations (∼0.20 μm). Probable adiabatic shear occurred on chip segmentation at HSC Copyright © 2007 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study was conducted in twenty-three butcheries in the city of Taquaritinga, State of São Paulo, Brazil, surveyed during a 10 months period. Among two hundred and eighty-seven Escherichia coli strains isolated from samples of ground beef, meat-grinding-machines and the hands of manipulators, five were recognized as extraintestinal pathogenic E. coli (ExPEC), showing virulence factors (P and S fimbriae, hemolysin and aerobactin) and presenting multidrug resistance. Retail-sold food may constitute an important vehicle for the dissemination of ExPEC in communities, giving rise to reasons for concern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The information concerning the molecular events taking place in onlay bone grafts are still incipient. The objective of the present study is to correlate the effects of perforation of resident bone bed on (1) the timing of onlay autogenous graft revascularization; (2) the maintenance of volume/density of the graft (assessed through tomography); and (3) the occurrence of bone remodeling proteins (using immunohistochemistry technique) delivered in the graft. Thirty-six New Zealand White rabbits were subjected to iliac crest onlay bone grafting on both sides of the mandible. The bone bed was drill-perforated on one side aiming at accelerating revascularization, whereas on the other side it was kept intact. After grafts fixation and flaps suture all animals were submitted to tomography on both mandible sites. Six animals were sacrificed, respectively, at 3, 5, 7, 10, 20 and 60 days after surgery. A second tomography was taken just before sacrifice. Histological slides were prepared from each grafted site for both immunohistochemistry analysis [osteopontin, osteocalcin, type I collagen and vascular endothelial growth factor (VEGF) anti-bodies] and histometric analysis. The values on bone volume measured on tomography showed no statistic significance (P≥0.05) between perforated and intact sites. Grafts placed on perforated beds showed higher bone density values compared with non-perforated ones at 3 days (P≤0.05). This correlation was inverted at 60 days postoperatively. The findings from VEGF labeling revealed a tendency for earlier revascularization in the perforated group. The early revascularization of bone grafts accelerated the bone remodeling process (osteocalcin, type I collagen and osteopontin) that led to an increased bone deposition at 10 days. The extended osteoblast differentiation process at intermediate stages in the perforated group cooperated for a denser bone at 60 days. © 2008 Blackwell Munksgaard.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The knowledge of dental occlusion should be considered the basic foundation to an excellent orthodontic practice. The patient's diagnose without the centric relation assessment can take the orthodontist to an unpleasant surprises. The use of rectangular archwires requires occlusal contacts been checked to decide what kind of the dental movement will be necessary to achieve the dental equilibrium and mainly to investigate if the movement will be possible. Considering the occlusal surfaces complexity, the occlusal adjustment by selective grinding should be performed during the orthodontic treatment to allow vertical dental movements reducing treatment's time. Occlusal interferences are responsible not only for biomechanics adverse effects, producing undesirable dental movements, but also for potential side effects such as excessive forces (occlusal trauma), leading to roots reabsorption. The occlusal adjustment is a determinant point on dental balance after the end of orthodontics treatments, where each posterior occlusal tooth contacts A and B, or B and C on buccolingual aspect, as well as the stoppers and equalizers contacts on mesiodistal direction must be achieved and well established. The appropriate role of anterior teeth in mandibular movements must be determined, allowing immediate disclusion of posterior teeth, known as anterior guide, and promoting protecting muscle forces to the stomatognathic system. Selective grinding should not be used. in place of well planned and executed orthodontic movement. Aim: The aim of this article is to present the rationale use of occlusal adjustment in Orthodontics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study evaluated the long-term effects of orthognathic surgery on subsequent growth of the maxillomandibular complex in the young cleft patient. Patients and Methods: We evaluated 12 young cleft patients (9 male and 3 female patients), with a mean age of 12 years 6 months (range, 9 years 8 months to 15 years 4 months), who underwent Le Fort I osteotomies, with maxillary advancement, expansion, and/or downgrafting, by use of autogenous bone or hydroxyapatite grafts, when indicated, for maxillary stabilization. Five patients had concomitant osteotomies of the mandibular ramus. All patients had presurgical and postsurgical orthodontic treatment to control the occlusion. Radiographs taken at initial evaluation (T1) and presurgery (T2) were compared to establish the facial growth vector before surgery, whereas radiographs taken immediately postsurgery (T3) and at longest follow-up (T4) were used to determine postsurgical growth. Each patient's lateral cephalograms were traced, and 16 landmarks were identified and used to compute 11 measurements describing presurgical and postsurgical growth. Results: Before surgery, all patients had relatively normal growth. After surgery, cephalograms showed statistically significant growth changes from T3 to T4, with the maxillary depth decreasing by -3.3° ± 1.8°, Sella-nasion-point A by -3.3° ± 1.8°, and point A-nasion-point B by -3.6° ± 2.8°. The angulation of the maxillary incisors increased by 9.2° ± 11.7°. Of 12 patients, 11 showed disproportionate postsurgical jaw growth. Maxillary growth occurred predominantly in a vertical vector with no anteroposterior growth, even though most patients had shown anteroposterior growth before surgery. The distance increased in the linear measurement from nasion to gnathion by 10.3 ± 7.9 mm. Four of 5 patients operated on during the mixed dentition phase had teeth that erupted through the cleft area. A variable impairment of postoperative growth was seen with the 2 types of grafting material used. No significant difference was noted in the effect on growth in patients with unilateral clefts versus those with bilateral clefts. The presence of a pharyngeal flap was noted to adversely affect growth, whereas simultaneous mandibular surgery did not. After surgery, 11 of 12 patients tended toward a Class III end-on occlusal relation. Conclusions: Orthognathic surgery may be performed on growing cleft patients when mandated by psychological and/or functional concerns. The surgeon must be cognizant of the adverse postsurgical growth outcomes when performing orthognathic surgery on growing cleft patients with the possibility for further surgery requirements. Performing maxillary osteotomies on cleft patients would be more predictable after completion of facial growth. © 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the investigation of an abrasive process for finishing flat workpieces, based on the combination of important grinding and lapping characteristics. Instead of loose abrasive grains between the workpiece and the lapping plate, a resinoid grinding wheel of hot-pressed silicon carbide is placed on the plate of a device resembling a lapping machine. The resin bond grinding wheel is dressed with a single-point diamond. In addition to keeping the plate flat, dressing also plays the role of interfering in the behavior of the process by varying the overlap factor (Ud). It was found that the studied process simplify the set-up and can be controlled more easily than in lapping, whose is a painstaking process. The surface roughness and flatness deviation proved comparable to those of lapping, or even finer than it, with the additional advantage of a less contaminated workpiece surface with a shiny appearance. The process was also monitored by acoustic emission (AE), which indicates to be a promissing and suitable technique for use in this process. Copyright © 2008 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Petrobras produced green petroleum coke (GPC) is a carbon rich fuel, virtually ash-free, with low sulfur content, and is a fuel suitable to replace metallurgical coke in blast furnaces. The GPC was tested in a pulverized coal injection simulator built in the Volta Redonda research center. It presented a low burning efficiency due to low volatile material content and high substitution rate by the carbon content. The tests were carried out in blast furnaces with ≤ 50% Petrobras GPC in the coal blends. The injected coal/CVP mixtures produced no negative side effects in the blast furnace grinding systems, pneumatic conveying, or operating process. The mixture burning process inside the blast furnace showed a decrease in fuel consumption, with a significant reduction in metallurgical coke consumption. The industrial-scale tests of the GPC mixtures did not reach the 70% maximum for lack of the GPC feedstock, which is necessary to continue with standard coal mixtures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the critical problems in implementing an intelligent grinding process is the automatic detection of workpiece surface burn. This work uses fuzzy logic as a tool to classify and predict burn levels in the grinding process. Based on acoustic emission signals, cutting power, and the mean-value deviance (MVD), linguistic rules were established for the various burn situations (slight, intermediate, severe) by applying fuzzy logic using the Matlab Toolbox. Three practical fuzzy system models were developed. The first model with two inputs resulted only in a simple analysis process. The second and third models have an additional MVD statistic input, associating information and precision. These two models differ from each other in terms of the rule base developed. The three developed models presented valid responses, proving effective, accurate, reliable and easy to use for the determination of ground workpiece burn. In this analysis, fuzzy logic translates the operator's human experience associated with powerful computational methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of minimum lubrication, optimized and conventional cooling at different flows and application rates of cutting fluids on the quality of hardened-steel pieces produced by external cylindrical plunge grinding with super-abrasive grinding wheels with low CBN concentrations was verified. The analysis of the quality of the pieces was performed through the assessment of the behavior of the specific energy of the grinding, roughness, roundness deviation, and the generated residual stress. By analyzing of the application ways and of the several flows and application rates of the cutting fluid, one could encounter lubrication/cooling conditions that enable the reduction in cutting fluid volume, reduction in grinding time without compromising the dimensional parameters (superficial finishing, surface integrity). Regarding the different applications of cutting fluids, it could be noted the optimized application for higher velocities has presented the best performance, demonstrating the effectiveness of the new concept of nozzle utilized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paresthesia of the lower lip is uncommon during orthodontic treatment. In the present case, paresthesia occurred during orthodontic leveling of an extruded mandibular left second molar. It was decided to remove this tooth from the appliance and allow it to relapse. A reanatomization was then performed by grinding. The causes and treatment options of this rare disorder are reviewed and discussed. The main cause of paresthesia during orthodontic treatment may be associated with contact between the dental roots and inferior alveolar nerve, which may be well observed on tomography scans. Treatment usually involves tooth movement in the opposite direction of the cause of the disorder.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Euphorbia tirucalli Lineu (Aveloz) belongs to the family Euphorbiaceae and is used in the treatment of cancer and warts. Some studies have reported that phorbol esters are the active principles responsible for the antitumor activity of Aveloz. The production of these molecules occurs in greater quantity in May, during the morning. This study aimed to evaluate whether the physico-chemical parameters of Aveloz homeopathic aqueous solutions such as pH, electrical conductivity and refractive index change due to storage time. Such parameters were measured regularly for 180 days. All solutions were prepared according to the method of grinding with lactose and subsequent dissolution in aqueous medium, as described in the Brazilian Homeopathic Pharmacopoeia, using as starting point the Aveloz latex collected in May. Homeopathic aqueous solutions containing only lactose were also prepared and evaluated as a control group. The potencies that were analyzed for electrical conductivity, pH and refractive index were: 4cH, 7cH, 9cH, 12cH, 14cH, 15cH, 29cH, 30cH. As a result, we found out that there was only statistical difference (p=0.035) in electrical conductivity between the homeopathic solutions containing Aveloz and the homeopathic solutions without Aveloz, when 15cH potency was compared. We also observed that the electrical conductivity increased with the aging of the solutions but is not directly related to the pH or the refractive index of the solutions, indicating that the aging process may alter the electrical conductivity of the homeopathic medicines. The presence of gas inside the glass that stores these solutions may affect the electrical conductivity measurements. Finally, no statistically significant difference was observed (p> 0.05) in the pH and refractive index.