176 resultados para Adjustable suture


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many incisions have been described for approaches to zygomatic fractures. Precise repositioning of zygomatic complex fractures is difficult. The traditional approach is through an eyebrow incision, but it can produce a scar that causes aesthetic and psychological problems for the patient. We describe the supratarsal fold approach to expose the frontozygomatic suture and to reduce small displacements of frontal sinus anterior wall; it gives good access and excellent aesthetic results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Facial injuries vary in their clinical characteristics and complexity, deserves an appropriate approach for each case, considering that the failures may result in aesthetic and functional changes that can be harmful both functionally and psychologically. Aspects such as exposure time of the injury, anesthesia, suture materials and tetanus prophylaxis are important factors. The objective is to present a case of extensive facial injuries in an automobile accident patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare two forms of scheduling clinical dental care for the oral health teams (OHT) included in the strategy of family health, regarding productive aspects of assistance. Methods: Two OHT worked concurrently, using two methods of clinical care: the parameter recommended by the Ministry of Health Ordinance No. 1101, 2002, which establishes 03 dental visits per hour (c/h) per team, and a Testing model, with 02 c/h, being each method applied for a period of 615 hours. The quantitative data was collected in OHTs’ daily production spreadsheets, covering the following items: the number of dental visits (initial, for maintenance and for emergency procedures), procedures performed, consumption of material and sterilization cycles. Data was compared and statistically analyzed through the BioStat 5.0 by applying the paired t-test (p <0.05). Results: Under the Ministerial method and the Testing model, were performed, respectively, 288 and 365 first dental visits, 921 and 686 return dental visits, 167 and 172 emergency dental attendances, with 469 and 110 fouls, 212 and 327 treatments were finished and 2501 and 3046 dental procedures were realized. Among eleven analyzed consumables, five were consumed in smaller quantities in the Testing model: gloves (9%), anesthesia (38%), anesthetic needle (34%), suture material (24%) and aspirators (11%), while the six remaining items presented similar consumption rates between the two models. Conclusions: The testing model revealed to be more productive and economical.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Calvaria grafts provide good bone quantity for the reconstruction of the atrophic maxilla, and have lower morbidity and resorption rates when compared to iliac crest. The aim of this paper is to present the technique for obtaining a graft of the skull. Initially, the depth of the osteotomy is determined by a manually conducted bur, which establishes the limits of the structures of the skull (outer table, diploe and inner table), making the removal of bone blocks easier and safer. Thus, osteotomies of the blocks are made with greater security, avoiding the complications inherent to surgical technique. The case that will be presented it is from a male patient of 65 years who refused to submit to the iliac crest graft, opting for the calvaria, despite being bald, that is a contraindication for this treatment modality. A delicate suture associated with placement of titanium mesh to maintain the conformation of the patient's skull in the region of the bone defect, created after removal of the graft, provided a good cosmetic result at the donor site. The use of titanium mesh for re-anatomization of bone defects created in the grafts is well indicated for bald patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The genus Mycteria (Ciconiidae) is composed of species with controversial phylogenetic hypotheses of relationships. This study sought to describe the cranial osteology of the four species included in the genus Mycteria, comparing with representative species from other genera of the family. The monophyly of Mycteria coud be hypothesized based on the following cranial characters: 1) medial process of the mandible medially oriented and 2) pseudo temporal tubercle developed when compared to other species Ciconiidae. Mycteria ibis and M. leucocephala are sister groups supported by: 1) deep temporal fossa, 2) reduced “T” tubercle and 3) expansion of the caudal fossa coanalis relative to other species of Ciconiidae. Among the species studied, the most basal was M. cinerea and the taxon formed by M. ibis and M. leucocephala is sister group of M. americana, sustained by the presence of total fusion of lacrimal and frontal bones, whereas in remaining species of Ciconiidae the suture between these bones is visible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concentrations of acute phase proteins are correlated with the severity of the surgical trauma, being elevated when severe tissue injury is produced. The aim of this study was to evaluate the leukogram and the acute phase proteins concentrations in healthy female dogs submitted to minimally invasive ovariohysterectomy, with the use of nylon cable ties (G1), and conventional (laparotomy) ovariohysterectomy, with the use of nylon suture (G2), as methods to ligate the ovarian pedicles and uterine body, respectively. Blood samples from 30 adult healthy female dogs (15 for each group) were obtained before surgery, and at 24 and 48 h and 7 days after surgery. Serum protein fractions were determined by means of sodium dodecyl sulfate polyacrylamide gel electrophoresis. Neutrophilia was observed 24 h after both surgical procedures but did not differ (P ≥ 0.05) between the groups. In G1, the estimated concentration of ceruloplasmin increased (P ≤ 0.05) 48 h after the surgical procedure. The estimated ceruloplasmin concentration was significantly higher in G1 (P ≤ 0.05) when compared to G2 48 h postoperatively, and the estimated haptoglobin concentration was also significantly greater in G1 (P ≤ 0.05) than in G2 from 24 h to 7 days after surgery. Through the ceruloplasmin and haptoglobin estimated concentrations, we conclude that the minimally invasive ovariohysterectomy caused a more intense inflammatory response, which was not reflected in the white blood cell count.