181 resultados para Adesivos dentinarios


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Evaluate the impact of the use of strip adhesive over the quality of life of institutionalized patients and wearers of complete dentures. Material and method: Twenty-nine institutionalized patients wearers of complete denture were selected to this study and after a clinical exam, a questionnaire (adjusted and based upon the index of Oral Health Impact Profile and Oral Health-Related Quality of Life, OHIP and OHQOL) was applied to evaluate issues related to epidemiological conditions (gender and age), quality of life (pain, discomfort, functional limitations, phonetic, social, psychological and esthetic), taste and notion of implant treatment. Following this part, the patients received instruction to use the strips adhesives (Corega Fita Adesiva, Glaxo-Smith-Kline, Rio de Janeiro, Brazil), considering three in maxillary prosthesis and two in the lower prosthesis during a period of 30 days. After this period, all the patients were recall and the questionnaire was reapplied; add some adhesive performance questions, to compare the results before and after the adhesive use in terms of percentage. Result: After the adhesive strips use there were improvement of the functional, social and physcological limitation aspects, but without percentual increasement of phonetic and esthetics aspects. The results showed 65.5% of the answers stating adhesive maintenance between 6-12 hours, easy removal (68.9%), and without change the taste (89.6%). The notion for implant treatment was decreased changing from 75.8 to 37.9% after the adhesive use. Conclusion: The results enhanced a positive impact over quality of life of the respondents after the strip adhesive use, showing decrease of pain and discomfort, mainly of inferior dental prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this literature review was to evaluate the use of fibrin tissue adhesive in implant dentistry. Materials and Methods: A literature search of Medline-PubMed for articles published, describing the use of fibrin tissue adhesive in implant dentistry was performed and articles were critically reviewed. Results: The literature review reveals clinical trials and experimental studies with regard to the use of fibrin tissue adhesive in implant dentistry. This material consists of 2 components: highly purified, freeze-dried human fibrinogen with factor XIII and a starter solution containing human thrombin. Clotting factor XIII is admitted for reinforcement of the fibrin network. The components are reconstituted before use and when mixed form a clot by mimicking the terminal phase of the physiological clotting cascade. Several studies showed that fibrin tissue adhesive is fully absorbed by macrophages within 2 weeks of application. Adhesive fibrin tissue may be used for to prevent bone loss, to create contour in the periimplant soft tissue and osseous tissue, to sculpt emergence profile for prosthetic components and to mimic tissue architecture. In the last years fibrin tissue adhesive also find use as material for the controlled delivery of drugs and biologics. Conclusions: The fibrin tissue adhesive presents good properties such as biocompatibility, hemostatic properties and ability to break down like the physiologic clot. This material, alone or associated with other materials, can be used with the implants immediately after extraction. In this condition it brings the necessary anchoring and efficient maintenance of osseous/mucosal contour, which it is important for the clinical success.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the decades, there was an evolution in dentistry, specifically in filling technique, and Buonocore (1955) has been the introducer of Adhesive Era. Thus, this paper aims to review the literature about the current adhesive systems. Was performed a literature review about the 5th and 6th adhesive system generations. The titles and abstracts of published articles were analyzed in PubMed database over the past 5 years. However, there are still different views about the technique used, therefore, because the diversity of these materials, it is impossible to highlight one that presents the best efficiency in all situations, being the responsibility of the professional the knowledge of the techniques and clinical applicability of each material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The bone repair process is controlled by complex molecular mechanisms that involve systemic and local factors. Fibrin glue is derived from human plasma and mimics the final pathway of coagulation network. Tranexamic acid inhibits fibrinolysis and prevents or decreases the formation of degradation products of fibrin and fibrinogen. The purpose of this study was to evaluate histologically in rats the effect of tranexamic acid associated with the fibrin glue on bone healing. The experiment used 60 (n = 5) male rats in: GI: Control, GII: fibrin glue, GIII tranexamic acid and GIV /fibrin glue/tranexamic acid. Bone defect (2.5mm diameter) was created in right tibia. The animals were euthanized at 7,14 and 30 days postoperatively, and the pieces were processed with hematoxylin and eosin. The results showed at 7 days post-operative surgical cavity filled with dense connective tissue rich in fibroblasts, permeated by delicate neoformed bone trabeculae in percentage of 70-80% for GI, GII and GIII and GIV to 94.8%. At 14 days post-operative newly formed bone was found between 75-85% for GI, GII and GIII and percentage above 95% for GIV. At 30 days postoperative GI and GIV showed 95-100% of mature bone tissue; GII and GIII in percentage close to 80-90%. Based on the results and methodology is concluded that fibrin / tranexamic acid glue association has positive action on bone repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os diastemas contribuem para a quebra de harmonia dos dentes, comprometendo a beleza do sorriso; os incisivos superiores são os dentes que mais se destacam no sorriso, sendo muito importante a simetria e harmonia entre eles. Para o fechamento dos diastemas, durante muito tempo, as alternativas clínicas foram o emprego da Ortodontia e das próteses fixas. Atualmente, com a evolução dos sistemas adesivos e das resinas compostas, é possível reproduzir as características dos dentes com uma técnica simples, previsível, sem desgaste da estrutura dentária, reversível, com menor custo, proporcionando um resultado satisfatório e imediato. O propósito do presente artigo é apresentar três casos clínicos de fechamento de diastemas generalizados associados ou não a outras alterações que comprometem o sorriso do paciente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: a proposta desse estudo foi avaliar, por meio de microscopia eletrônica de varredura (MEV), a interface adesiva após a descolagem de acessórios ortodônticos, fixados em dentes bovinos com emprego de adesivo hidrofílico e hidrofóbico, em condições distintas de umidade do substrato dentário. Métodos: foram utilizados 20 incisivos inferiores, divididos em quatro grupos (n = 5): Grupo I , empregou-se o sistema de colagem contendo o primer hidrofílico Transbond MIP e a pasta adesiva Transbond XT, aplicados em substrato úmido; Grupo II, empregou-se o sistema de colagem primer hidrofóbico Transbond XT e pasta adesiva em substrato úmido; Grupos III e IV, os braquetes foram colados com os mesmos sistemas de união dos Grupos I e II, porém com esmalte dentário seco. Removidos os acessórios, avaliou-se em MEV, em diferentes magnificações, a interface adesiva e a interação dos sistemas adesivos com o esmalte dentário. As imagens foram avaliadas qualitativamente, observando-se o embricamento mecânico para o adesivo hidrófilo em quaisquer condições de substrato. Resultados: a falta de umidade no esmalte condicionado permitiu uma melhor interação entre os materiais de ligação e a estrutura adamantina. O adesivo hidrofóbico apresentou o pior resultado de interação micromecânica quando aplicado a uma estrutura dentária úmida; já o sistema hidrofílico mostrou-se versátil, obtendo resultados aceitáveis em condições de umidade e excelente interação na ausência de contaminação. Conclusão: os autores afirmam que a melhor condição do esmalte dentário para a aplicação de primers é com a ausência de umidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze the behavior of the flow of heat (temperature) through the thickness of panels LVL (Laminated veneer lumber) produced with phenol formaldehyde adhesive, in laboratorial and industrial scales. Experimental program was conducted with five LVL panels (three produced in laboratorial scale and two in industrial scale) with different arrangements of a mix of commercial veneers from tropical pinus from the south region of Sao Paulo State, Brazil, bonded using phenol formaldehyde adhesive. The temperature inside the panels during the pressing process was evaluated using thermocouples type T (cooper-constantan), installed mostly in the center of the glue lines and connected to a data acquisition system. The graphics of temperature as a function of the time showed a gradual increase of temperature up to pre-set values, remaining constant from them. The temperature reached at the center of the panels was adequate to promote the curing of the adhesive. These pre-set values were similar to the minimum values presented by other authors and manufacturers of these adhesives that affirm that temperatures above 100ºC at the center of laminated panels bonded with phenolic adhesives are sufficient to ensure proper cure of the resin. The time necessary for curing of the adhesives confirmed the validity of practical expressions provided by adhesive manufacturers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)