242 resultados para titanium implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Transitional implants are indicated for cases in which immediate loading is counter-indicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. Method and Materials: The present literature review was based on the OldMedline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. Results: The transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. Conclusion: Transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading. (Quintessence Int 2011; 42: 19-24)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of craniofacial implants is an effective treatment for patients with deformities, burns, and cancer sequelae. The sites with the most successful implants are the auricular, nasal, and orbital regions. Furthermore, other factors can affect the implant longevity such as irradiated area, surgical technique, bone quality and quantity, macrostructure and microstructure of the implant, maintenance, and systemic factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the process of facial rehabilitation, the mobility of ocular prostheses must be considered. Whereas some factors depend exclusively on the dentist, such as molding techniques and selection of material for denture construction, regarding ocular rehabilitation, factors, such as type of surgery, whether to adopt implants, and the use of lubricants, deserve special attention owing to their integration and their association with other factors pertaining exclusively to the patient. To establish harmony, and with the intention of aiding the dentist, after a discerning evaluation, the authors of this study report the factors that provide greater or less mobility to ocular prostheses and conceal the prosthesis in a more natural way, thereby contributing toward achieving a favorable aesthetic result in rehabilitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implant-retention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 100, and 200 mu m, respectively. The crowns were attached by titanium retention screw with 30 N/cm to external hexagonal osseointegrated implants embedded in acrylic resin. After 2 min, the retention screw of each replica was submitted to detorque evaluation by an analogic torque gauge. Three retention screws were used to perform detorque evaluation at each replica and the procedure was repeated twice with each screw. Each group was submitted to 72 detorque measurements. Data were evaluated by ANOVA and Tukey test (P < 0.05). All groups exhibited significant decrease (P < 0.05) in preload and the lowest decrease occurred in Group A. Groups B, C, and D were statistically significant different from Group A (P < 0.05), but there was no statistically significant difference between Groups B and D (P > 0.05). Crowns with unilateral misfit presented higher preload decrease than crowns completely fitted to osseointegrated implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This in vitro study assessed the effect of a 4% TiF4 varnish on demineralisation and remineralisation of sound enamel and artificial carious enamel lesions, respectively.Methods: Bovine sound and carious enamel (n = 110) were randomly allocated to each type of varnish: Duraphat (R))-D (NaF, 2.26%F, pH 4.5, Colgate-Brazil, n = 30), Duofluorid (R)-F (NaF, 2.71%F, pH 8.0, FGM-Brazil, n = 30), TiF4-T (2.45%F, pH 1.0, FGM-Brazil, n = 30) and no-fluoride-P (FGM-Brazil, pH 5.0, n = 20). For the formation of artificial enamel caries, half of the blocks were immersed in 32 mL buffer acetate solution (16 h), whereas the other half was maintained sound. The varnishes were applied onto the enamel surfaces. Thus, the samples were subjected to pH cycles (37 degrees C) for 7 days. The response variables tested were surface and cross-sectional hardness. Data were tested using Kruskal-Wallis test (p < 0.05).Results: All F varnishes significantly reduced demineralisation and increased remineralisation in comparison to placebo. The TiF4 did not significantly reduce the surface enamel softening when compared with the other F varnishes, but it decreased the loss of subsurface hardness to the same extent. In enamel blocks with previous artificial carious lesions, the TiF4 significantly improved the rehardening compared to the other varnishes up to 30 mu m depth.Conclusions: The TiF4 varnish was able to decrease the demineralisation and increase the remineralisation of previously sound and carious enamel, respectively. It was equally effective compared to NaF varnishes on reducing the demineralisation at subsurface, but it was more effective on improving the remineralisation at surface and subsurface. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This in situ/ex vivo study assessed the effect of titanium tetrafluoride (TiF4) on permanent human enamel subjected to erosion.Design: Ten volunteers took part in this study performed in two phases. In the first phase (ERO), they wore acrylic palatal appliances containing two enamel blocks, divided into two rows: TiF4 (F) and no-TiF4 (no-F). During the 1st day, the formation of a salivary pellicle was allowed. In the 2nd day, the TiF4 solution was applied on one row (ERO + F), whereas on the other row no treatment was performed (ERO + no-F). From 3rd until 7th day, the blocks were subjected to erosion, 4x per day. In the 2nd phase (no-ERO), the volunteers wore acrylic palatal appliances containing one enamel block, during 2 days, to assess the effect of TiF4 only (no-ERO + F). Enamel alterations were determined using profilometry (wear), microhardness (%SMHC) tests, scanning electron microscope and microprobe analysis. The %SMHC and wear were tested using ANOVA and Tukey's post hoc tests (p < 0.05).Results: The mean of %SMHC and wear ( mu m) values ( +/- S.D.) were, respectively: ERO + F -73.32 +/- 5.16(A)/2.40 +/- 0.60(a); ERO + no-F -83.49 +/- 4.59B/1.17 +/- 0.48(b) and no-ERO + F -67.92 +/- 6.16(A)/0.21:E 0.09(c). In microscope analysis, the no-F group showed enamel with honeycomb appearance. For F groups, it was observed a surface coating with microcracks. The microprobe analysis revealed the presence of the following elements (%) in groups ERO + F, ERO + no-F and no-ERO + F, respectively: Ca (69.9, 72.5, 66.25); P (25.9, 26.5, 26.06); Ti (3.0, 0, 5.93).Conclusions: The TiF4 was unable to reduce dental erosion. (c) 2007 Elsevier Ltd. All rights reserved.