200 resultados para Taxa de retorno


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radiotherapy, computational systems are used for radiation dose determination in the treatment’s volume and radiometric parameters quality analysis of equipment and field irradiated. Due to the increasing technological advancement, several research has been performed in brachytherapy for different computational algorithms development which may be incorporated to treatment planning systems, providing greater accuracy and confidence in the dose calculation. Informatics and information technology fields undergo constant updating and refinement, allowing the use Monte Carlo Method to simulate brachytherapy source dose distribution. The methodology formalization employed to dosimetric analysis is based mainly in the American Association of Physicists in Medicine (AAPM) studies, by Task Group nº 43 (TG-43) and protocols aimed at dosimetry of these radiation sources types. This work aims to analyze the feasibility of using the MCNP-5C (Monte Carlo N-Particle) code to obtain radiometric parameters of brachytherapy sources and so to study the radiation dose variation in the treatment planning. Simulations were performed for the radiation dose variation in the source plan and determined the dosimetric parameters required by TG-43 formalism for the characterization of the two high dose rate iridium-192 sources. The calculated values were compared with the presents in the literature, which were obtained with different Monte Carlo simulations codes. The results showed excellent consistency with the compared codes, enhancing MCNP-5C code the capacity and viability in the sources dosimetry employed in HDR brachytherapy. The method employed may suggest a possible incorporation of this code in the treatment planning systems provided by manufactures together with the equipment, since besides reducing acquisition cost, it can also make the used computational routines more comprehensive, facilitating the brachytherapy ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, it is presented a novel method for calculating some intrinsic parameters such as capture mean time, thermic emission mean time, capture probability and noise gain on quantum well infrared photodetectors. Such devices are built by depositing layers of semiconductors of different energy gap, forming quantum wells. The present method uses rate equations to describe the occupation of discrete states of the quantum wells, that together with noise gain equations given in literature, are solved self consistently. The input data of the method is experimental measurement of dark current (current measured with no relevant incident photon) versus applied bias. In order to validate this approach, the values obtained were compared with results from literature

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the effects of unilateral isokinetic strength training at high speed (180°.s-1) of the dominant leg on the rate of force development (RFD) of the contralateral limb. The study included 18 male individuals, apparently healthy, with an average of 23 years, and without regular practice of physical activities. The subjects were divided randomly into two groups: control group (GC) and isokinetic group (GISOC). Assessments were made of the values of peak isometric torque (PT isom) and RFD of both lower limbs in the pre-training. So, the GISOC underwent an isokinetic strength training with high speed (180°.s-1) for 6 weeks, with the dominant leg only and then reassessed. It was found that there was no significant improvement in value of PT isom (p> 0.05), and the RFD for the dominant limb had a significant improvement (p< 0.05) compared to the pre-training and that there was no transfer of values to the contralateral side (p> 0.05). It can be concluded that the isokinetic training at high speed was not enough for significant cross education

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Boron Neutron Capture Therapy (BNCT), based on the 10B(n,α)7Li reaction, represents a promising modality for the treatment of cancers that are resistents to conventional treatments. So, it is necessary to find drugs (boron compounds) with high selectivity for each type of cancer, the neutrons source should be well characterized and the rate of 10B(n,α)7Li reaction should be measured with great accuracy as possible. This study aimed to develop a method for manufacturing thin films of boron, for measure the 10B(n,α)7Li reaction, and analyze the uniformity of the films. Five thin films of boron were manufactured with three different concentrations of boric acid, heated to transform the acid in boron, irradiated with thermic neutrons coupled to CR-39 detectors, in BNCT line at the reactor IEA-R1 IPEN/CNEN, São Paulo. After the irradiation, the detectors were chemically attacked with NaOH to reveal the tracks. The methodology presented is effective because it resulted in deposition of boron as thin film enabling the quantitative analysis of 10B(n,α)7Li reaction. The analysis of the uniformity of density of the induced tracks in CR-39 shows that, in most of the films, there is no uniformity in surface distribution of boron, but when the film is divided, we obtain some uniform sectors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infertility is directly related to chromosomal abnormalities in germ cells. Among them, the aneuploidies are the most frequent chromosomal abnormalities and responsible for embryo implantation failures, miscarriages, fetal losses and newborns with congenital malformations, mental disability and neuropsychomotor developmental delay. Male patients with normal somatic karyotype may present different rates of aneuploidies in sperm, resulting in abnormal embryos. This study aimed to correlate the frequency of chromosomal aneuploidies in spermatozoa with embryo implantation rate in couples undergoing assisted reproductive techniques. The methodology has included chromosomal analysis by GTG banding and molecular cytogenetic study using Fluorescent In Situ Hybridization technique for evaluation of chromosomes 9, X and Y in germ cells of 22 patients referred to the Human Reproduction Service of the Clinical Hospital FMRP-USP. Embryo implantation rates were determined by hormonal evaluation in maternal peripheral blood and ultrasound confirmation. Two patients presented abnormal karyotype, characterized by polymorphism of the heterochromatic region of the long arm of chromosome 9 and a satellite in the short arm of chromosome 22. Both alterations, usually considered variants of normality, have been related to infertility phenotype and miscarriages. Significant differences were detected between couples who presented pregnancy (group 1) and couples with embryo implantation failure (group 2), with higher frequency of aneusomy and diploidy of chromosome 9, as well as total aneuploidy in sperm of group 2 patients. Our results suggest a correlation between aneuploidy and embryo implantation rates, since the infertile group with reproductive failure has showed higher frequency of aneuploidy. Screening for aneuploidies detection in male germ cells should be included in order to decrease embryo implantation failures, miscarriages and fetuses with chromosomal ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a study about the mechanical properties of the API 5L X70 steel, with or without heat treating, has been made, with the intetion of assess the influence of cooling after the austenitization heat treating by air cooling (normalizing) and a rapid cooling with oil (tempering). This steel is known by high strength and ductility values and it is commonly used in the manufacture of oil pipes. The growing energy demand encouraged the study and manufacture of this material. Although this microalloyed dispense subsequent heat treatings, it was proven that its implementation is very advantageous for this type of application, improving hardness and plastic stability. It was also assessed that the faster the cooling rate is, the better will be these properties

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clicar acesso eletrônico abaixo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work aims to study the characteristics of the alloy Al - 7 % Si - 0 , 3Mg ( AA356 ) , more specifically characterize the macrostructure and microstructure and mechanical properties of the alloy ingots AA356 obtained in metal molds and sand molds for power studying the structures through the difference of cooling rates . This alloy is explained by the fact of referring league has excellent combination of properties such as low solidification shrinkage and good fluidity, good weldability , high wear resistance , high strength to weight ratio, has wide application in general engineering , and particularly in the automotive and aerospace engineering . In this work we will verify this difference in properties through two different cooling rates . We monitor the solid solidification temperatures by thermocouples building with them the cooling curve as a tool that will aid us to evaluate the effectiveness of the grain refining because it achieved with some important properties of the alloy as the latent heat of solidification fraction the liquid and solid temperatures, the total solidification time, and identify the presence of inoculants for grain refinement. Thermal analysis will be supported by the study of graphic software “Origin “will be achieved where the cooling curve and its first derivative that is the cooling rate. Made thermal analysis, analysis will be made in macrographs ingots obtained for observation of macrostructures obtained in both types of ingots and also analysis of micrographs where sampling will occur in strategic positions ingots to correlate with the microstructure. Finally will be collecting data from Brinell hardness of ingots and so then correlating the properties of their respective ingots with cooling rate. We found that obtained with cast metal ingots showed superior properties to the ingots obtained with sand mold

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of previous active static stretch on the peak torque (PT) and rate of force development (TDF) during isokinetic concentric contractions at 60 and 180.s-1 in active individuals. Twelve active subjects with ages between 18 and 30 years participated of this study. The individuals were submitted in different days to the following tests: 1) Familiarization session to the isokinetic dynamometer; 2) Five maximal isokinetic concentric contractions for knee extensors at each angular velocity (60 and 180.s-1) to determine PT and TDF (Control), and; 3) Two active static stretching exercises for the dominant leg extensors (10 x 30 s for each exercise, with 20 s of rest). After the stretching, the isokinetic test was repeated (Post-Stretching). The conditions 2 and 3 were performed in random order. There was no significant modification after the stretch exercises on the PT, angle and time at which the PT was attained, at 60 and 180º.s-1. In the same way, there was no significant modification on the TDF and angle at which the maximal TDF was attained in both angular speeds. In other way, the time to attain maximal TDF (TTDF) at 180º.s-1 was significantly lower after the stretching (Pre - 98.3 ± 27.5 ms and Post - 86.6 ± 30.2 ms). There was significant modification on the torque (60 and 180º.s-1) and time (60º.s-1) at different delta of angle variations, obtained at 60º.s-1 at Control and Post-Stretching conditions. However, there was significant reduction of time after the stretching exercises on delta of angle variations of 90-88º (Pre - 46.6 ± 6.5 ms and Post - 44.1 ± 5.1 ms), 88-85º (Pre - 65.8 ± 7.9 ms and Post - 63.3 ± 4.9 ms) and 85-80º (Pre - 93.3 ± 7.7 ms and Post - 90.0 ± 4.2 ms) at 180º.s-1. With base on these data, it is possible to conclude that PT and TDF do not modify after static stretching, irrespectively on the speed...(Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies regarding the quality and quantity of water have become more and more important because of the increasing negative environmental impacts occurred and their scarcity increase as well. At the Center of Tropical Fish Research (Centro de Pesquisas de Peixes Tropicais - CEPTAlIBAMA) located in the city of Pirassununga, SP, there is a dam named Represa Velha which supplies 128 tanks that are fish hatcheries. This dam takes in part of the Barrinha stream micro-basin where it has been observed strong impacts due to the deforestation of its support forest, as well an the intensive agricultural activities in the neighboring areas. There has been established and distributed 13 points of water-collectors disposed inside the stream and the dam. The water samples were taken from the stream only from its surface because of the low depth and, inside. In the dam, the water samples were taken at the water column, at a 50cm distance over the sediment. In every point of collection inside the dam, it was placed a chamber of sedimentation, vertically in the water column at a 70% height from the total depth. The collections took place during the dry/cold and raining/warm periods of the years 2000 and 2001. Then, it were analyzed the physical, physical-chemical, chemical and micro-biological parameters of the water samples. The obtained results were statistically analyzed throughout the SAS system (Statistical Analisys System). Parameters such as total phosphate, nitrate, nitrite and turbidity were within the established limits for the Class 2 water, according to the n° 20/1986 CONAMA Resolução. However, the total and Escherichia coli coliforms, mainly inside the Barrinha stream, had showed values above of the established limits for the same... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper consists in applying the Modern Theory of Portfolio (MPT) using central position measurements for modeling the return on investment fund of a renowned financial institution and compare with the Medium- CVaR model. The measurement of risks and returns becomes increasingly important for investors to minimize their losses to maximize thus their possibilities of earnings, taking into account sudden change scenarios. We present concepts of investment funds used as data and research on central position measurements to determine which measure was more suitable. To assemble the Efficient Frontier of assets considering the method proposed measure of central position-CVaR position is used MatLab. Then, after getting the Frontier, it was possible to compare it with the Medium-CVaR model, already proven effective. Finally, we analyze the viability of the proposed model in portfolio management